Background: This study evaluates the diagnostic accuracy of ultrasound-guided fine needle aspiration (US-FNA) and core needle biopsy (US-CNB) for detecting axillary lymph nodes in women with breast cancer.Methods: Eligible studies and pertinent literature resources were identified in Cochrane, PubMed, Embase, CNKI, VIP, and Wanfang databases using subject-specific keywords. Study outcomes were tested for heterogeneity, and meta-analyses were performed to estimate sensitivity, specificity, and diagnostic odds ratios (DORs). The summary receiver operating characteristic (SROC) curve analysis was also performed.Results: A total of 22 studies involving 3,548 patients were included to evaluate the diagnostic accuracy of US-FNA and 11 studies involving 758 patients were included to evaluate the diagnostic accuracy of US-CNB in identifying axillary lymph nodes in women with breast cancer. The accuracy of US-FNA in identifying suspicious axillary lymph nodes was as follows: overall sensitivity, 79% (95% CI: 73%–84%); global specificity, 96% (95% CI: 92%–98%); overall positive likelihood ratio, 18.55 (95% CI: 10.53–32.69); overall negative likelihood ratio, 0.22 (95% CI: 0.17–0.28); DOR, 71.68 (95% CI: 37.19–138.12); and the area under the SROC curve, 0.94 (95% CI: 0.92–0.96). The accuracy of US-CNB in identifying suspicious axillary lymph nodes was as follows: overall sensitivity, 85% (95% CI: 81%–89%); global specificity, 93% (95% CI: 87%–96%); overall positive likelihood ratio, 11.88 (95% CI: 6.56–21.50); overall negative likelihood ratio, 0.16 (95% CI: 0.12–0.21); overall DOR, 66.83 (95% CI: 33.28–134.21), and the area under SROC curve 0.96 (95% CI: 0.94–0.97).Conclusions: The results indicate that both US-FNA and US-CNB have high accuracy for suspicious axillary lymph nodes.
Objective: To measure wall shear stress (WSS), oscillatory shear index (OSI) and relative residence time (RRT) at multiple locations along the femoropopliteal artery in adults without peripheral artery disease (PAD), and to investigate whether low WSS, high OSI and/or high RRT are present in regions with a high prevalence of atherosclerotic lesions. Materials and methods: A total of 116 presumed healthy adult volunteers were recruited. Ankle-brachial index and lower-limb arterial duplex ultrasound assessments were performed to exclude participants with PAD. Maximum WSS, mean WSS, and OSI were measured at the near and far walls of ten arterial sites along the femoropopliteal artery using ultrasound vector flow imaging (VFI). RRT was calculated from OSI and mean WSS values obtained via VFI. Results: A total of 113 participants (46 males and 67 females; 222 lower limbs), with a mean age of 37.6 years, were included in the analysis. Compared to the overall mean values across all 20 measurement sites, significantly higher OSI and higher RRT were recorded at the posterior wall of the common femoral artery ( P < 0.01), while significantly lower WSS, higher OSI, and higher RRT were observed at the posterior wall of the femoral artery bifurcation ( P < 0.01). The distal superficial femoral artery (SFA) at the adductor canal demonstrated significantly lower WSS and higher OSI at both near and far walls ( P < 0.01). When comparing hemodynamic indices between sexes, males exhibited significantly lower WSS at several near-wall sites, significantly higher OSI at multiple near- and far-wall sites, and significantly higher RRT at the near wall of the proximal SFA and the far wall of the profunda femoris artery ( P < 0.05). Conclusions: Variations in WSS, OSI, and RRT are evident along the femoropopliteal artery in adults without PAD. Notably, the distal SFA at the adductor canal demonstrated significantly lower and more oscillatory WSS, consistent with the region's reported high prevalence of atherosclerotic plaque and occlusion. Whether these hemodynamic patterns contribute to lesion development later in life remains uncertain and warrants further investigation.
18 December 2023 in Frontiers in Cardiovascular Medicine
Abdominal vascular compression syndrome (AVCS) is caused by the compression of abdominal blood vessels by adjacent structures or the compression of abdominal organs by neighboring blood vessels. Such compressions can result in a variety of clinical symptoms. They are not commonly seen in ultrasound practices, and their presence may have been underrecognized and underdiagnosed. This article reviews the clinical features, ultrasound characteristics, and diagnostic criteria of four types of AVCS, namely, celiac artery compression syndrome, renal vein compression syndrome, iliac vein compression syndrome, and superior mesenteric artery syndrome to increase awareness of these conditions among ultrasound practitioners. The ultrasound criteria for AVCS are primarily based on studies with small sample sizes, and therefore, it is important to exercise caution if these criteria are used.
The purpose of this study was to ascertain the utility of sonography with the echo-tracking (ET) technique to assess vascular stiffness in rabbits with hypercholesterolemia and atherosclerosis. Grayscale sonography associated with the ET technique was used to measure the elastic modulus (Ep) of the aorta in cholesterol-fed rabbits (group T1, n = 44, for 4 weeks; group T2, n = 44, for 12 weeks) and normal control rabbits (group C1, n = 44; group C2, n = 44). The aortic Ep values and blood biochemical markers between groups were compared using analysis of covariance. Light and transmission electron microscopic evaluation were used to demonstrate atherosclerotic changes in the aorta. The Ep values of the aorta in group T1 and T2 rabbits were significantly higher than those of group C1 and C2 controls (88.74 ± 27.99 and 100.96 ± 24.81 vs 64.38 ± 20.23 and 72.35 ± 18.43, p = .124). Also, the Ep values of the aorta between group T1 and T2 rabbits were significantly different ( p = .033). Light and transmission electron microscopy confirmed morphologic typical changes of aortic atherosclerosis in groups T1 and T2. Grayscale sonography with the ET method could be used to evaluate tissue elastic changes in arterial walls associated with atherosclerosis and hypercholesterolemia.
1 January 2022 in Annals of Translational Medicine
Background: This study sought to investigate the accuracy of estimating left atrial pressure (LAP) using the continuous wave Doppler spectrum of mitral regurgitation. Methods: Dog models of left atrial hypertension with mitral regurgitation were established with disposable biopsy forceps and the injection of melamine formaldehyde resin microsphere suspension. A total of 40 models of left atrial hypertension with different hemodynamic statuses were established by injecting either esmolol or dobutamine in which the spectrums of mitral regurgitation were clear and the regurgitation velocity exceeded 3.5 m/s. The continuous wave Doppler spectrums of mitral regurgitation were recorded and analyzed to estimate left atrial pressure (LAPECHO). The mean left atrial pressure (LAPC-MEAN), the isovolumic diastolic left atrial pressure (LAPC-IVRT), the maximum left atrial pressure (LAPC-MAX), and the minimum left atrial pressure (LAPC-MIN) were also measured using the catheter method in the same cardiac cycle. Results: The LAPECHO (mean ± standard deviation; 11.77±4.36 mmHg) was correlated with the LAPC-MEAN (11.51±4.77 mmHg; r=0.887, P=0.000), but the difference was not statistically significant (P=0.459). The LAPECHO was correlated with the LAPC-IVRT (12.16±4.72 mmHg; r=0.883, P=0.000), but the difference was not statistically significant (P=0.271). There was a correlation between the LAPC- MEAN and the LAPC-IVRT (r=0.987, P=0.000), and the difference was statistically significant (P=0.000). Conclusions: This study suggests that the ultrasound evaluation of LAP correlates well with LAP measured using the gold standard catheter method, and is a simple, convenient, non-invasive method to quantitatively estimate LAP. This method is promising, but further large-scale animal experiments and clinical studies need to be conducted.