Haining Zheng

Dr. Haining Zheng


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2023 in Frontiers in Oncology
Verified
Journal Article
Open access
HZHaining Zheng
Haining Zheng
RZRui Zhao
Rui Zhao
WWWei Wang
Wei Wang
XLXiaona Liu
Xiaona Liu
XWXiaoqing Wang
Xiaoqing Wang
YRYubo Ren
Yubo Ren
Background: This study evaluates the diagnostic accuracy of ultrasound-guided fine needle aspiration (US-FNA) and core needle biopsy (US-CNB) for detecting axillary lymph nodes in women with breast cancer.Methods: Eligible studies and pertinent literature resources were identified in Cochrane, PubMed, Embase, CNKI, VIP, and Wanfang databases using subject-specific keywords. Study outcomes were tested for heterogeneity, and meta-analyses were performed to estimate sensitivity, specificity, and diagnostic odds ratios (DORs). The summary receiver operating characteristic (SROC) curve analysis was also performed.Results: A total of 22 studies involving 3,548 patients were included to evaluate the diagnostic accuracy of US-FNA and 11 studies involving 758 patients were included to evaluate the diagnostic accuracy of US-CNB in identifying axillary lymph nodes in women with breast cancer. The accuracy of US-FNA in identifying suspicious axillary lymph nodes was as follows: overall sensitivity, 79% (95% CI: 73%–84%); global specificity, 96% (95% CI: 92%–98%); overall positive likelihood ratio, 18.55 (95% CI: 10.53–32.69); overall negative likelihood ratio, 0.22 (95% CI: 0.17–0.28); DOR, 71.68 (95% CI: 37.19–138.12); and the area under the SROC curve, 0.94 (95% CI: 0.92–0.96). The accuracy of US-CNB in identifying suspicious axillary lymph nodes was as follows: overall sensitivity, 85% (95% CI: 81%–89%); global specificity, 93% (95% CI: 87%–96%); overall positive likelihood ratio, 11.88 (95% CI: 6.56–21.50); overall negative likelihood ratio, 0.16 (95% CI: 0.12–0.21); overall DOR, 66.83 (95% CI: 33.28–134.21), and the area under SROC curve 0.96 (95% CI: 0.94–0.97).Conclusions: The results indicate that both US-FNA and US-CNB have high accuracy for suspicious axillary lymph nodes.

1 January 2022 in Annals of Translational Medicine
Verified
Journal Article
Open access
PDF file
HZHaining Zheng
Haining Zheng
YJYan Jin
Yan Jin
YFYuwei Fu
Yuwei Fu
RZRui Zhao
Rui Zhao
XWXiaoqing Wang
Xiaoqing Wang
CWChao-Yang Wen
Chao-Yang Wen
Background: This study sought to investigate the accuracy of estimating left atrial pressure (LAP) using the continuous wave Doppler spectrum of mitral regurgitation. Methods: Dog models of left atrial hypertension with mitral regurgitation were established with disposable biopsy forceps and the injection of melamine formaldehyde resin microsphere suspension. A total of 40 models of left atrial hypertension with different hemodynamic statuses were established by injecting either esmolol or dobutamine in which the spectrums of mitral regurgitation were clear and the regurgitation velocity exceeded 3.5 m/s. The continuous wave Doppler spectrums of mitral regurgitation were recorded and analyzed to estimate left atrial pressure (LAPECHO). The mean left atrial pressure (LAPC-MEAN), the isovolumic diastolic left atrial pressure (LAPC-IVRT), the maximum left atrial pressure (LAPC-MAX), and the minimum left atrial pressure (LAPC-MIN) were also measured using the catheter method in the same cardiac cycle. Results: The LAPECHO (mean ± standard deviation; 11.77±4.36 mmHg) was correlated with the LAPC-MEAN (11.51±4.77 mmHg; r=0.887, P=0.000), but the difference was not statistically significant (P=0.459). The LAPECHO was correlated with the LAPC-IVRT (12.16±4.72 mmHg; r=0.883, P=0.000), but the difference was not statistically significant (P=0.271). There was a correlation between the LAPC- MEAN and the LAPC-IVRT (r=0.987, P=0.000), and the difference was statistically significant (P=0.000). Conclusions: This study suggests that the ultrasound evaluation of LAP correlates well with LAP measured using the gold standard catheter method, and is a simple, convenient, non-invasive method to quantitatively estimate LAP. This method is promising, but further large-scale animal experiments and clinical studies need to be conducted.

24 August 2022 in Vascular Medicine
Verified
Journal Article
Closed access
RZRui Zhao
Rui Zhao
HZHaining Zheng
Haining Zheng
WWWei Wang
Wei Wang
YDYigang Du
Yigang Du
YTYisha Tong
Yisha Tong
CWChao-Yang Wen
Chao-Yang Wen
Introduction: This study aims to evaluate changes in the arterial spectral Doppler waveform in a canine artery stenosis model. Methods: Canine femoral artery stenosis models were established in 12 beagle dogs. Doppler waveforms were recorded in the femoral artery preoperatively and postoperatively in the femoral artery and at the ankle after formation of a 50%, 70%, and 90% stenosis or occlusion. Major descriptors for arterial Doppler waveform were used to analyse waveforms. Results: The proportion of multiphasic waveforms proximal to a moderate stenosis decreased compared to normal baseline, although the difference was not statistically significant, whereas the decreases at the stenosis, distal to the stenosis, and at the ankle were significant ( p < 0.05). The decreases in arteries with a more severe stenosis or occlusion were significant at all locations ( p < 0.05). The proportion of high resistive waveforms decreased significantly at the ankle in the arteries with a moderate stenosis (50%) ( p = 0.002), but the decreases proximal to, at, and distal to the stenosis were not significant. The decreases were significant at all locations in the arteries with a more severe stenosis ( p < 0.05). The decrease was significant at the ankle in the arteries with an occlusion ( p < 0.001) but not significant pre, at, and post an occlusion. Conclusions: Phasicity and resistance of Doppler waveforms alter in canine femoral arteries with a stenosis. Phasicity change seems more sensitive in response to an arterial stenosis than resistance change. Additional information on arterial resistance could be obtained using end-diastolic ratios, resistive indices, and potentially end-systolic notch velocity measurements.

20 November 2025 in Frontiers in Surgery
Verified
Journal Article
Open access
PDF file
HZHaining Zheng
Haining Zheng
MGMeiying Gao
Meiying Gao
JCJin Cui
Jin Cui
XZXiaoying Zhang
Xiaoying Zhang
WLWenjie Li
Wenjie Li
CWChao-Yang Wen
Chao-Yang Wen
Objective: This study aims to develop and internally validate a multivariable logistic regression model and a simplified scoring system, based on standardized ultrasonographic features, for the preoperative differentiation of retroperitoneal ganglioneuroma (GN) from schwannoma (SW), and to evaluate their discrimination, calibration, and clinical utility. Methods: We retrospectively included patients with retroperitoneal GN or SW confirmed by surgical pathology. Standardized ultrasonographic features were extracted, and candidate predictors were selected using least absolute shrinkage and selection operator (LASSO) regression, while retaining potential confounders (age, sex, lesion long diameter). A multivariable model was constructed, and a six-variable simplified score was derived. Discrimination [area under the curve (AUC)], calibration (intercept, slope, Brier score), and decision curve analysis (DCA) were evaluated using stratified fivefold cross-validation and bootstrap resampling ( B = 2,000). Two task-oriented thresholds were predefined: R1 [rule-out, sensitivity (Se) ≥ 0.95] and S1 [standard diagnosis, specificity (Sp) ≥ 0.50]. Results: A total of 74 patients were included (GN, 25, 33.8%; SW, 49, 66.2%). After optimism correction, the multivariable model achieved an AUC of 0.930, and the simplified score achieved an AUC of 0.917. Independent predictors included pelvic extraperitoneal location ( loc_pelvic = 1), absence of cystic/necrotic change, and lower SD/LD ratio. For R1, the model threshold of 0.149 yielded Se = 0.960, Sp = 0.837, and negative predictive value (NPV) = 0.976; the score threshold of 0.206 yielded Se = 1.000, Sp = 0.592, and NPV = 1.000. For S1, the model threshold of 0.426 yielded Se = 0.920 and Sp = 0.939, and the score threshold of 0.594 yielded Se = 0.760 and Sp = 0.918. Conclusion: Both the multivariable model and the simplified score demonstrated excellent performance in differentiating GN from SW, suggesting potential value as rapid, interpretable tools for bedside use and in resource-limited settings. Their clinical utility should be confirmed through external validation and recalibration in multicenter, prospective cohorts and further enhanced through integration with multimodal imaging such as CT, MRI, and contrast-enhanced ultrasound (CEUS).

16 February 2023 in Research Square
Verified
Preprint
Open access
PDF file
HZHaining Zheng
Haining Zheng
RZRui Zhao
Rui Zhao
WWWei Wang
Wei Wang
XLXiaona Liu
Xiaona Liu
XWXiaoqing Wang
Xiaoqing Wang
YRYubo Ren
Yubo Ren
Background: This study performed an overall assessment of the accuracy of ultrasound-guided fine-needle aspiration (FNA) and core needle biopsy (CNB) for detecting axillary lymph nodes in women with breast cancer based on qualified studies.Methods: Eligible studies and pertinent literature resources were identified on Cochrane, PubMed, Embase, CNKI, VIP, and Wanfang databases through searching key words or terms. The latest study was published in the March 2020. The eligible publications contained cohort and cross-sectional researches. All the publications obtained were tested for heterogeneity, and corresponding effect models were used to calculate amalgamative values of sensitivity, specificity and diagnostic odds ratio (DOR). Analysis of summary receiver operating characteristic (SROC) was performed on suspicious axillary lymph nodes.Results: A total of 22 studies involving 3548 patients were included to explore the accuracy of FNA in identifying axillary lymph nodes in women with breast cancer. 11 studies involving 758 patients were included to explore the accuracy of CNB in identifying axillary lymph nodes in women with breast cancer. The accuracy of FNA in identifying suspicious axillary lymph nodes was specifically as follows: overall sensitivity was 79% (95%CI: 73%-84%), global specificity was 96% (95%CI: 92%-98%), overall positive likelihood ratio was 18.55 (95% CI: 10.53-32.69), overall negative likelihood ratio was 0.22 (95% CI: 0.17-0.28), the overall DOR was 71.68 (95%CI: 37.19-138.12), and the acreage under the SROC was (AUC = 0.94; 95% CI: 0.92-0.96). The accuracy of CNB in identifying suspicious axillary lymph nodes was specifically as follows: overall sensitivity was 85% (95%CI: 81%-89%), global specificity was 93% (95%CI: 87%-96%), overall positive likelihood ratio was 11.88 (95% CI: 6.56-21.50), overall negative likelihood ratio was 0.16 (95% CI: 0.12-0.21), the overall DOR was 66.83 (95%CI: 33.28-134.21), and the acreage under the SROC was (AUC = 0.96; 95% CI: 0.94-0.97).Conclusions: The results indicated that both FNA and CNB had high accuracy for suspicious axillary lymph nodes.

25 March 2026 in Critical Care Medicine
Verified
Journal Article
Open access
HZHaining Zheng
Haining Zheng
WWWei Mm Wang
Wei Mm Wang
XLXiaona Liu
Xiaona Liu
XWXiaoqing Mm Wang
Xiaoqing Mm Wang
SZShuanglong Mm Zhang
Shuanglong Mm Zhang
PLPing Liang
Ping Liang
OBJECTIVES: To assess critical care ultrasound (CCUS) utilization, training coverage, and barriers to implementation among ICU clinicians across economically diverse regions in China. DESIGN: An online cross-sectional survey with chi-square tests, Mann-Whitney U tests, multivariate logistic regression, and principal component analysis (PCA)-based clustering. SETTING: ICU clinicians from all 31 provincial-level regions in mainland China, classified into high- and low-gross domestic product (GDP) groups by per capita GDP relative to the national average. SUBJECTS: Six hundred fifty-five ICU clinicians who completed the survey. INTERVENTIONS: The survey included demographics, CCUS training experience, equipment availability, clinical usage frequency, and perceived implementation barriers. MEASUREMENTS AND MAIN RESULTS: A total of 61.4% of respondents reported receiving CCUS training, with similar coverage between high- and low-GDP regions (61.9% vs. 60.8%; p = 0.769). Clinicians from high-GDP areas reported significantly higher self-assessed ultrasound proficiency ( p = 0.008). Dedicated ultrasound equipment was unavailable in approximately one-third of ICUs, slightly more common in low-GDP regions (37.7% vs. 31.4%; p = 0.094). Major barriers included insufficient expert support (36.9%), lack of ultrasound consultants (31.3%), and difficulties in image interpretation (31.1%). Logistic regression analysis showed structured training significantly reduced the odds of encountering equipment-related barriers (odds ratio, 0.57; 95% CI, 0.34–0.97; p = 0.036). PCA-based clustering identified three clinician profiles: frequent users (high training and usage, predominantly from high-GDP areas), moderate users, and infrequent users (limited training and primarily from low-GDP regions). CONCLUSIONS: Structured CCUS training significantly enhances utilization and clinician expertise, irrespective of regional economic conditions. Policies promoting standardized training, equitable equipment distribution, and sustainable expert support are essential for broader CCUS integration in critical care settings across China.