Yufeng Yan

Yufeng Yan


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Chinese Optics
Verified
Journal Article
Closed access
PDF file
PGPan Guo-Tao
Pan Guo-Tao
长春长春理工大学光电工程学院,吉林长春130022
长春理工大学光电工程学院,吉林长春130022
YYYufeng Yan
Yufeng Yan
YXYu Xin
Yu Xin
ZLZhang Lei
Zhang Lei
LCLtd. No. 8 Branch Jilin Jiangji Special Industry Co.
Ltd. No. 8 Branch Jilin Jiangji Special Industry Co.
The predecessor of China Optics was China Optics and Applied Optics Digest, which was founded in 1985. At that time, it was the only retrieval journal in the field of optics in China. At the end of 2008, China Optics and Applied Optics Digest was renamed 《中国光学》的前身是1985年创办的《中国光学与应用光学文摘》,当时是国内光学领域唯一的检索刊物。2008年底《中国光学与应用光学文摘》转型更名为《中国光学与应用光学》期刊,刊载内容突破了文摘的限制,正式成为学术刊物。

1 January 2022 in Chinese Optics
Verified
Journal Article
Closed access
PDF file
DMDU Du Ming-xin
DU Du Ming-xin
YYYufeng Yan
Yufeng Yan
ZRZhang Zhang Ran
Zhang Zhang Ran
CCCai Cai Cun-liang
Cai Cai Cun-liang
YXYu Yu Xin
Yu Yu Xin
YYYu Yu Yang
Yu Yu Yang
The predecessor of China Optics was China Optics and Applied Optics Digest, which was founded in 1985. At that time, it was the only retrieval journal in the field of optics in China. At the end of 2008, China Optics and Applied Optics Digest was renamed 《中国光学》的前身是1985年创办的《中国光学与应用光学文摘》,当时是国内光学领域唯一的检索刊物。2008年底《中国光学与应用光学文摘》转型更名为《中国光学与应用光学》期刊,刊载内容突破了文摘的限制,正式成为学术刊物。

22 March 2022 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
ZZZhenchao Zhang
Zhenchao Zhang
YYYufeng Yan
Yufeng Yan
XYXin Yu
Xin Yu
CLChenxiao Li
Chenxiao Li
LGLekai Gong
Lekai Gong
Inner diameter measurement technology with high precision and wide measuring ranges is a difficult area to master. It is challenging to achieve high precision and a wide measuring range for inner diameter measurement. The dispersive confocal technique is used to describe a high accuracy, large range approach for measuring inner diameter. The inner diameter is measured utilizing a rotating scanning approach that combines the dispersive confocal technique with least squares. Meanwhile, a plane mirror deflects the optical path of a dispersive confocal sensor, focusing monochromatic light of a certain wavelength on the objects surface in the radial direction. The measuring range of the device may be modified to fit different objects by modifying the distance between the dispersive confocal sensor and the plane mirror, as well as the eccentricity of the dispersive confocal sensor. Furthermore, this study examines the methods accuracy and suggests a calibration technique. As a consequence, the procedure may ensure measurement precision as well as a measurement range. Finally, experiments are utilized to test the validity of the strategy. To accomplish a 3μm inner diameter measurement precision and a measuring range of 76mm to 150mm, a dispersive confocal sensor with a range of just 20mm was utilized.

23 November 2022 in IEEE Photonics Journal
Verified
Journal Article
Open access
PGPan Guotao
Pan Guotao
XYXin Yu
Xin Yu
WWWu Wang
Wu Wang
XNXiaolong Ni
Xiaolong Ni
DDDapeng Dong
Dapeng Dong
YYYufeng Yan
Yufeng Yan
Adaptive optics (AO) can effectively improve the beam quality of solid-state slab lasers. However, the aperture of the output beam increases as the output power of the laser increases, resulting in a larger measurement system. Ultimately, a more complex AO system needs to be designed. To meet the requirements of conjugate imaging in an AO system, it is of research significance to coordinate and optimize the system's structural dimensional parameters while enabling the detection of multiple parameters, such as the wave-front and beam quality. In this paper, a multiparameter measurement technique in a large-aperture rectangular laser beam aberration-correction system is proposed. The system layout is optimized with total dimensions of 400 mm × 150 mm × 246 mm (L × W × H). The AO system conforms to the requirements for conjugate detection and can perform wave-front detection, far-field evaluation, and near-field detection of a 160 mm × 120 mm rectangular beam produced from a solid-state slab laser. The findings reveal that the measured PV values of wave-fronts of the measurement system are less than 0.288 μm, the RMS is no more than 0.079 μm, the average far-field beam quality factor is 1.248 times the diffraction limit, and the average near-field beam uniformity is 0.533 at a temperature of 20°C ± 10°C; these results satisfy the technical parameters.