Mold exposure in early life may be associated with development of atopic dermatitis; however, studies of this link are inconclusive and evidence for the underlying mechanism(s) is lacking. This study identified the association between the time of mold exposure and development of atopic dermatitis and investigated the underlying mechanisms. The association between atopic dermatitis and mold exposure was examined in the Cohort for Childhood Origin of Asthma and Allergic Diseases birth cohort study (n=1446). Atopic dermatitis was diagnosed at 1 year of age by pediatric allergists. Exposure to mold was assessed by questionnaire. The Illumina MiSeq platform was used to examine the environmental mycobiome in 20 randomly selected healthy infants and 20 infants with atopic dermatitis at 36 weeks of gestation. Prenatal, but not postnatal, mold exposure was significantly associated with atopic dermatitis (adjusted odds ratio, 1.36; 95% confidence interval, 1.01-1.83). Levels of total serum IgE at 1 year of age were higher in infants with atopic dermatitis exposed to mold during pregnancy than in healthy infants not exposed to mold during pregnancy (p=0.021). The relative abundance of uncultured Ascomycota was higher in infants with atopic dermatitis than in healthy infants. The relative abundance of uncultured Ascomycota correlated with total serum IgE levels at 1 year of age (r=0.613, p<0.001). Indoor mold exposure during the fetal period is associated with development of atopic dermatitis via IgE-mediated allergic inflammation. Avoidance of mold exposure during this critical period might prevent the development of atopic dermatitis.
The 2014 Time-Use Survey of Statistics Korea revealed that office workers are increasingly spending more than eight hours at work. This study conducted an exposure assessment for office workers in Korea. Indoor and outdoor air pollutants were measured in offices. A self-administered questionnaire was employed to determine work information, indoor air quality (IAQ) awareness, and subjective symptoms for 328 workers. Indoor air concentrations for measured air pollutants were below IAQ guideline values. The average concentrations of target air pollutants did not show significant differences except for benzene, which had relatively a higher concentration in national industrial complexes. The indoor benzene, ethylbenzene, and acetaldehyde concentrations were higher in offices where workers were having dry eye, ophthalmitis, and headache symptoms. This study provides reference values to manage IAQ in offices, suggesting that if the benzene concentration exceeds 4.23 μg/m3 in offices, it could cause dry eye symptoms. Considering the increasing working hours for office workers and health effects, workers’ exposure to indoor pollutants should be reduced. In addition, the IAQ was heavily influenced by outdoor air levels and various indoor sources. Therefore, in areas with relatively high air pollution, greater monitoring and management is required considering the influence of outdoor air quality.
The effect of deposition temperature and film thickness on the work function of gate electrodes has been studied. It is shown that the work function of can be tuned from 4.28– on , 4.40– on , and 4.44– on . For high- dielectrics, the work function can be tuned by on each side of the band gap, making it a suitable electrode for fully depleted silicon-on-insulator devices. Furthermore, deposition at high temperature increases the work function to while Si implantation increases it to , making a good -type metal candidate.
31 December 2021 in Journal of Environmental Health Sciences
Dongjun Kim, Gihong Min, Jihun Shin, Youngtae Choe, Kilyoong Choi, Sang Hyo Sim, and Wonho Yang. J Environ Health Sci. 2024;50:16-24. https://doi.org/10.5668/JEHS.2024.50.1.16
31 October 2024 in Journal of Environmental Health Sciences