Partial discharge (PD) is a phenomenon often occurring in insulation system defects (cavities), which can significantly affect life and reliability. While broad knowledge on PD phenomenology of high-frequency transformers (HFT) has been achieved under ac sinusoidal voltage, much less work has been done to infer PD behavior under emerging high frequency pulsewidth modulation (PWM) operation conditions. An impediment has been the limited appropriate test equipment. A recently developed novel ±5 kV GaN-based high-frequency PWM supply with controllable dV/dt , voltage level and frequency has been developed. This article explores the application of these measurements to the testing of materials in this electrical environment. Two commonly used windings for HFT were tested under different applied voltage magnitudes, frequencies, and slew rates. According to the test results, at high frequency (up to 50 kHz) the electric field generated by space charge deposited by PD occurring during previous PWM pulses plays an important role in PD behavior. The frequency dependent permittivity of the insulation material can also affect PD measurement results.
11 June 2019 in IEEE Transactions on Industrial Electronics
Partial discharge (PD) detection is a fundamental tool for the design and diagnosis of insulation systems, particularly organic materials that must operate throughout their life without PD. While the methods for PD measurements under sinusoidal supply voltage are well established, the same does not hold under repetitive-pulse voltage waveforms, such as those provided by inverters. Electromagnetic noise generated by electronic switch commutation in inverters can overlap with PD pulses, making it difficult to measure, separate from noise and identify PD. This is particularly more cumbersome when fast rise-time switches are employed. To address these issues, this work investigates methods to detect PD pulses on enameled wires under repetitive impulsive voltages with different rise-times of 60 ns, 500 ns and 1000 ns, proposing techniques which allows separation of PD from noise even when they overlap in time and frequency domain. This work employs a time-domain approach using standard deviation curve acquired from a set of measurements to discriminate PD from repetitive commutation disturbance. These techniques can be implemented to achieve unsupervised noise rejection, which would be an important goal for both off-line and on-line PD testing. The proposed approach is validated successfully through tests carried out on a low-voltage motor.
Partial discharges (PD) are the most common and harmful threat to the health of electrical insulation of high voltage (HV) and high field (HF) equipment. The occurrence of PD activity in HV and MV equipment is at the same time a cause and a sign of insulation degradation that may eventually result in the breakdown of the HV power equipment. For the safe and reliable operation of HV power equipment, continuous PD monitoring needs to be conducted conveniently to prevent any unplanned power outages and damage to electrical power equipment. The ultra-high frequency (UHF) PD measurement method has been widely used as an effective technique to detect PD activity on HV power equipment due to its non-invasive principle. To enable PD detection accuracy, there is still a need for more sensitive PD sensors that can assist the UHF PD monitoring system by suppressing ambient background noise and low-frequency electromagnetic interferences from telecommunication such as GSM signals. To tackle the sensitivity issues, this article presents a new design of ultra-wideband (UWB) microstrip patch antenna that is capable of effective suppression of low-frequency interference signals. The proposed antenna, designed, simulated, and optimized using the CST Microwave Studio software, has a bandwidth of 3.3GHz, below -10dB, in the operating frequency range of 1.2GHz-4.5GHz. The prototype of this antenna, printed on an FR4 substrate of a thickness of 1.6mm and a dielectric constant of 4.4, featuring a compact size of 100mm $\times100$ mm $\times1.6$ mm, was implemented to detect PD through laboratory experiments. This paper shows that the designed UWB antenna has high sensitivity, good noise rejection and it is, therefore, a promising candidate sensor for PD detection on HV equipment.
22 January 2021 in IEEE Transactions on Power Delivery
Condition assessment of Medium Voltage switchgears requires effective, but inexpensive solutions to become a common practice. On the other hand, failure of a switchgear component can cause cascade effects and outage of other apparatus, in addition to significant economic losses due, e.g., to lack of energy availability. A major diagnostic property to evaluate switchgear health and reliability is partial discharges, being a direct cause of failure of organic insulation systems. A new approach to automatic, self-assessment of switchgear reliability based on partial discharge, PD, acquisition and processing, as well as a new type of PD sensor solution are presented in this paper. The sensor is based on the capacitive divider existing in most bushings to indicate the presence or absence of voltage. The innovative automatic software is able to provide automatic noise and PD separation, noise rejection and type of PD-source identification. The embedded bushing sensor has been tested on switchgears in the presence of defective components as cable terminations and bushings. Results show that the sensor, coupled with the automatic software, is able to provide good sensitivity compared to other sensors, and good capability to locate the cabinet and identify the type of source generating partial discharges.