Maxim Bassis

Mr. Maxim Bassis

Ben-Gurion University of the Negev, Beersheba, Southern, Israel
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 August 2022 in Materials
Verified
Journal Article
Open access
PDF file
MBMaxim Bassis
Maxim Bassis
TRTomer Ron
Tomer Ron
ALAvi Leon
Avi Leon
AKAbram Kotliar
Abram Kotliar
RKRony Kotliar
Rony Kotliar
Eli AghionEli Aghion
Eli Aghion
A direct energy deposition (DED) process using wires is considered an additive manufacturing technology that can produce large components at an affordable cost. However, the high deposition rate of the DED process is usually accompanied by poor surface quality and inherent printing defects. These imperfections can have a detrimental effect on fatigue endurance and corrosion fatigue resistance. The aim of this study was to evaluate the critical effect of phase transition and printing defects on the corrosion fatigue behavior of 316L stainless steel produced by a wire laser additive manufacturing (WLAM) process. For comparison, a standard AISI 316L stainless steel with a regular austenitic microstructure was studied as a counterpart alloy. The structural assessment of printing defects was performed using a three-dimensional non-destructive method in the form of X-ray microtomography (CT) analysis. The microstructure was evaluated by optical and scanning electron microscopy, while general electrochemical characteristics and corrosion performance were assessed by cyclic potentiodynamic polarization (CCP) analysis and immersion tests. The fatigue endurance in air and in a simulated corrosive environment was examined using a rotating fatigue setup. The obtained results clearly demonstrate the inferior corrosion fatigue endurance of the 316L alloy produced by the WLAM process compared to its AISI counterpart alloy. This was mainly related to the drawbacks of WLAM alloys in terms of having a duplex microstructure (austenitic matrix and secondary delta-ferrite phase), reduced passivity, and a significantly increased amount of intralayer porosity that acts as a stress intensifier of fatigue cracking.

29 November 2021 in Metals
Verified
Journal Article
Open access
PDF file
MBMaxim Bassis
Maxim Bassis
AKAbram Kotliar
Abram Kotliar
RKRony Koltiar
Rony Koltiar
TRTomer Ron
Tomer Ron
ALAvi Leon
Avi Leon
Eli AghionEli Aghion
Eli Aghion
The wire laser additive manufacturing (WLAM) process is considered a direct-energy deposition method that aims at addressing the need to produce large components having relatively simple geometrics at an affordable cost. This additive manufacturing (AM) process uses wires as raw materials instead of powders and is capable of reaching a deposition rate of up to 3 kg/h, compared with only 0.1 kg/h with common powder bed fusion (PBF) processes. Despite the attractiveness of the WLAM process, there has been only limited research on this technique. In particular, the stress corrosion properties of components produced by this technology have not been the subject of much study. The current study aims at evaluating the effect of a slow strain rate on the stress corrosion resistance of 316L stainless steel produced by the WLAM process in comparison with its counterpart: AISI 316L alloy. Microstructure examination was carried out using optical microscopy, scanning electron microscopy (SEM) and X-ray diffraction analysis, while the mechanical properties were evaluated using tensile strength and hardness measurements. The general corrosion resistance was examined by potentiodynamic polarization and impedance spectroscopy analysis, while the stress corrosion performance was assessed by slow strain rate testing (SSRT) in a 3.5% NaCl solution at ambient temperature. The attained results highlight the inferior mechanical properties, corrosion resistance and stress corrosion performance, especially at a slow strain rate, of the WLAM samples compared with the regular AISI 316L alloy. The differences between the WLAM alloy and AISI 316L alloy were mainly attributed to their dissimilarities in terms of phase compositions, structural morphology and inherent defects.

15 October 2023 in Metals
Verified
Journal Article
Open access
PDF file
MBMaxim Bassis
Maxim Bassis
TRTomer Ron
Tomer Ron
ASAmnon Shirizly
Amnon Shirizly
Eli AghionEli Aghion
Eli Aghion
Additive manufacturing (AM) technology using the direct energy deposition (DED) process and wires as feedstock material is commonly used to produce large components at an affordable cost. The wire laser AM (WLAM) process is one type of DED technology that uses welding wire as the raw material and a laser beam as the energy source. The goal of this study was to understand and evaluate the effect of microstructure modifications on the stress corrosion endurance of 15-5 PH stainless steels produced through WLAM, compared to their counterpart wrought alloy AISI 15-5 PH. All the tested alloys were heat treated using a standard age hardening treatment (H-1150M) prior to their examination. The microstructure analysis was performed using optical and electron microscopy (SEM and TEM) and X-ray diffraction analysis. The environmental behavior was characterized through electrochemical examination using potentiodynamic polarization and impedance spectroscopy analysis, while stress corrosion behavior was evaluated by means of slow strain rate testing (SSRT). The corrosion experiments were conducted in a simulated corrosive environment in the form of a 3.5% NaCl solution. The results showed that the microstructure modifications in the WLAM alloy (mainly in terms of austenite content, passivation capability and inherent printing defects) have a significant detrimental effect on stress corrosion resistance.

25 February 2025 in Metals
Verified
Journal Article
Open access
PDF file
TRTomer Ron
Tomer Ron
ALAvi Leon
Avi Leon
MBMaxim Bassis
Maxim Bassis
Zhan ChenZhan Chen
Zhan Chen
ASAmnon Shirizly
Amnon Shirizly
Eli AghionEli Aghion
Eli Aghion
The present study aims to assess the impact of hot isostatic pressing (HIP) treatment on refractory high-entropy alloy (HEA) WTaMoNbV produced by the laser powder bed fusion (LPBF) process. This was carried out by examining the functional properties of this HEA in terms of mechanical and environmental performance. The microstructure of the tested HEA was evaluated using optical microscopy, scanning electron microscopy (SEM), and X-ray diffraction (XRD). Mechanical properties were examined via compression tests, while environmental behavior was evaluated by immersion tests and potentiodynamic polarization. The obtained results demonstrate that HIP treatment improved the alloy’s density from 11.27 to 11.38 g/cm3 and increased its ultimate compression strength by 11.5% (from 1094 to 1220 MPa). This modest favorable effect was attributed to the improvement in bulk properties by eliminating a large part of the sub-grain boundaries and reducing the amount of inherent printing defects, mainly in the form of internal cracking. The advantages offered by HIP were also manifested in surface quality improvement from N11 to N10 grades and enhanced environmental performance, reducing pitting density from 34,155 to 9677 pits/cm2.

31 May 2024 in Metals
Verified
Journal Article
Open access
PDF file
EHEfrat Hazan-Paikin
Efrat Hazan-Paikin
LTLital Ben Tzion-Mottye
Lital Ben Tzion-Mottye
MBMaxim Bassis
Maxim Bassis
TRTomer Ron
Tomer Ron
Eli AghionEli Aghion
Eli Aghion
The present study aims to evaluate the effect of up to 3 wt.% Nd on pure Zn in terms of physical properties and in vitro analysis. The use of Nd as an alloying element is due to its relatively adequate biocompatibility and its potential capability to reinforce metals with a hexagonal close-packed (HCP) crystal structure, such as Mg and Zn. The microstructural assessment was executed using X-ray diffraction analysis, along with optical and scanning electron microscopy. The mechanical properties were evaluated by hardness and tensile strength testing. The corrosion performance in simulated physiological environments was examined by means of immersion tests, potentiodynamic polarization, and impedance spectroscopy using phosphate-buffered saline (PBS) solution. Cytotoxicity assessment was carried out by indirect cell viability analysis according to the ISO 10993-5/12 standard using Mus musculus 4T1 cells, which are known to be very sensitive to toxic environments. The obtained results clearly highlighted the reinforcing effect of Nd in Zn-base alloys, mainly due to the formation of a secondary phase: NdZn5. This strengthening effect was acquired without impairing the inherent ductility and corrosion performance of the tested alloys. The cytotoxicity assessment indicated that the addition of Nd has a strong favorable effect on cell viability, which stimulates the inherent anti-inflammatory characteristics of Zn.

24 April 2026 in Metals
Verified
Journal Article
Open access
PDF file
MBMaxim Bassis
Maxim Bassis
ASAmnon Shirizly
Amnon Shirizly
Eli AghionEli Aghion
Eli Aghion
Additive manufacturing (AM) using powder bed fusion (PBF) has been the predominant printing method used over the last decade. The capability of this approach to produce complex parts with high precision has attracted the attention of major industries as a potential tool for replacing traditional manufacturing technologies. 15-5 PH stainless steel is one of the alloys being studied as a candidate for PBF processes. Its superior strength and corrosion resistance have made it a highly attractive option in numerous industries, including the automotive, nuclear, and petrochemical industries. To enhance the properties of 15-5 PH stainless-steel AM parts following printing, one can use a thermal treatment such as age hardening. However, very little research exists regarding the functional properties of AM parts made from this alloy after heat treatment. This study aims to evaluate the effect of H1150M age hardening heat treatment following printing on the properties of 15-5 PH steel, particularly regarding its mechanical properties and environmental behavior. The microstructure was studied using both optical and electron microscopy, along with X-ray diffraction (XRD) analysis. The mechanical properties were examined by tensile testing and fracture toughness assessment. Corrosion behavior was analyzed in terms of potentiodynamic polarization and using impedance spectroscopy. The results obtained have shown that over-aging caused by H1150M heat treatment has a detrimental effect on the mechanical and environmental behavior of the tested alloy. This was primarily attributed to the formation of an austenitic phase within the inherent martensitic matrix, the generation of brittle phases (mainly carbonitrides of Cr and Nb) and a reduction in grain size.