Jürgen Duchenne

Dr. Jürgen Duchenne

1. Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium
+1
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2025 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Closed access
ABAnca Balinisteanu
Anca Balinisteanu
Jürgen DuchenneJürgen Duchenne
Jürgen Duchenne
APAlexis Puvrez
Alexis Puvrez
LWLaurine Wouters
Laurine Wouters
SBStéphanie Bézy
Stéphanie Bézy
JVJens-Uwe Voigt
Jens-Uwe Voigt
Aims: To assess the inter-vendor differences in global longitudinal strain measurements and determine a potential improvement compared with the situation 10 years ago. Methods and results: 372 echocardiographic exams were performed in 62 subjects (50 male, age 56 ± 17) with LV ejection fraction ranging from 30% to 68%, using ultrasound systems from six manufacturers: GE, Philips, Canon, Siemens, Fujifilm and Esaote. Each subject was scanned consecutively on all machines by the same assigned sonographer, with two image sets per subject to assess test–retest setting reproducibility. Average peak systolic global strain from the three apical views (GLSAV) was measured on three vendor-specific (Canon, Siemens, and Fujifilm) and six vendor-agnostic (GE, Philips, US2.AI, Caas Qardia, Medis, and Epsilon) software solutions (SWS). Endocardial and mid-/full-wall GLS were measured and compared with the mean GLS of contemporary semi-automated clinical software: GE, Philips, Canon, Fujifilm, and Caas Qardia. Endocardial and mid-/full-wall GLS measurements from contemporary semi-automated clinical software showed minimal inter-vendor differences, with an average maximum bias of 0.6% strain units. There was a remaining inter-vendor bias with and among some other vendors. The average minimal detectable change with contemporary semi-automated clinical software was 2.5 and 2.4 strain% for endocardial and mid-/full-wall GLS, resp. These values were higher for and among some other vendors. Test–retest variability of GLS measurements was good and similar to that of LV ejection fraction (6.6% vs. 6.5%, P > 0.05), indicating consistent results across repeated scans. Conclusion: In this controlled study setting, GLS measurements from companies that provide contemporary semi-automated clinical software have become more consistent, compared with 10 years ago. Mid-/full-wall strain was now available in all but one software.

1 November 2022 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
SCSimon Calle
Simon Calle
Jürgen DuchenneJürgen Duchenne
Jürgen Duchenne
ABAhmed Beela
Ahmed Beela
ISIvan Stankovic
Ivan Stankovic
APAlexis Puvrez
Alexis Puvrez
FTFrank Timmermans
Frank Timmermans
Background: Septal strain patterns measured by echocardiography reflect the severity of left bundle branch block (LBBB)-induced left ventricular (LV) dysfunction. We investigated whether these LBBB strain stages predicted the response to cardiac resynchronization therapy in an observational study and developed a sheep model of LBBB-induced cardiomyopathy. Methods: The clinical study enrolled cardiac resynchronization therapy patients who underwent echocardiographic examination with speckle-tracking strain analysis before cardiac resynchronization therapy implant. In an experimental sheep model with pacing-induced dyssynchrony, LV remodeling and strain were assessed at baseline, at 8 and 16 weeks. Septal strain curves were classified into 5 patterns (LBBB-0 to LBBB-4). Results: The clinical study involved 250 patients (age 65 [58; 72] years; 79% men; 89% LBBB) with a median LV ejection fraction of 25 [21; 30]%. Across the stages, cardiac resynchronization therapy resulted in a gradual volumetric response, ranging from no response in LBBB-0 patients (ΔLV end-systolic volume 0 [−12; 15]%) to super-response in LBBB-4 patients (ΔLV end-systolic volume −44 [−64; −18]%) ( P< 0.001). LBBB-0 patients had a less favorable long-term outcome compared with those in stage LBBB≥1 (log-rank P =0.003). In 13 sheep, acute right ventricular pacing resulted in LBBB-1 (23%) and LBBB-2 (77%) patterns. Over the course of 8−16 weeks, continued pacing resulted in progressive LBBB-induced dysfunction, coincident with a transition to advanced strain patterns (92% LBBB-2 and 8% LBBB-3 at week 8; 75% LBBB-3 and 25% LBBB-4 at week 16) ( P =0.023). Conclusions: The strain-based LBBB classification reflects a pathophysiological continuum of LBBB-induced remodeling over time and is associated with the extent of reverse remodeling in observational cardiac resynchronization therapy-eligible patients.

2 November 2023 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
YMYankai Mao
Yankai Mao
Jürgen DuchenneJürgen Duchenne
Jürgen Duchenne
YYYuan Yang
Yuan Yang
CGChristophe Garweg
Christophe Garweg
YYYing Yang
Ying Yang
JVJens-Uwe Voigt
Jens-Uwe Voigt
Aims: Left bundle branch pacing (LBBP) has been shown to better maintain electrical synchrony compared with right ventricular pacing (RVP), but little is known about its impact on mechanical synchrony. This study investigates whether LBBP better preserves left ventricular (LV) mechanical synchronicity and function compared with RVP. Methods and results: Sixty patients with pacing indication for bradycardia were included: LBBP (n = 31) and RVP (n = 29). Echocardiography was performed before and shortly after pacemaker implantation and at 1-year follow-up. The lateral wall–septal wall (LW–SW) work difference was used as a measure of mechanical dyssynchrony. Septal flash, apical rocking, and septal strain patterns were also assessed. At baseline, LW–SW work difference was small and similar in two groups. SW was markedly decreased, while LW work remained mostly unchanged in RVP, resulting in a larger LW–SW work difference compared with LBBP (1253 ± 687 mmHg·% vs. 439 ± 408 mmHg·%, P < 0.01) at last follow-up. In addition, RVP more often induced septal flash or apical rocking and resulted in more advanced strain patterns compared with LBBP. At 1 year follow-up, LV ejection fraction (EF) and global longitudinal strain (GLS) were more decreased in RVP compared with LBBP (ΔLVEF: −7.4 ± 7.0% vs. 0.3 ± 4.1%; ΔLVGLS: −4.8 ± 4.0% vs. −1.4 ± 2.5%, both P < 0.01). In addition, ΔLW–SW work difference was independently correlated with LV adverse remodelling (r = 0.42, P < 0.01) and LV dysfunction (ΔLVEF: r = −0.61, P < 0.01 and ΔLVGLS: r = −0.38, P = 0.02). Conclusion: LBBP causes less LV mechanical dyssynchrony than RVP as it preserves a more physiologic electrical conduction. As a consequence, LBBP appears to preserve LV function better than RVP.

19 February 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AMAna Moya
Ana Moya
DBDimitri Buytaert
Dimitri Buytaert
MBMonika Beles
Monika Beles
Pasquale PaolissoPasquale Paolisso
Pasquale Paolisso
Jürgen DuchenneJürgen Duchenne
Jürgen Duchenne
MVMarc Vanderheyden
Marc Vanderheyden
Serial transthoracic echocardiographic (TTE) assessment of LVEF and GLS are the gold standard in screening Cancer Therapeutics-Related Cardiac Dysfunction (CTRCD). Non-invasive left-ventricle (LV) pressure–strain loop (PSL) emerged as a novel method to quantify Myocardial Work (MW). This study aims to describe the temporal changes and longitudinal trajectories of MW indices during cardiotoxic treatment. We included 50 breast cancer patients with normal LV function referred for anthracycline therapy w/wo Trastuzumab. Medical therapy, clinical and echocardiographic data were recorded before and 3, 6, and 12 months after initiation of the chemotherapy. MW indices were calculated through PSL analysis. According to ESC guidelines, mild and moderated CTRCD was detected in 10 and 9 patients, respectively (20% CTRCDmild, 18% CTRCDmod), while 31 patients remained free of CTRCD (62% CTRCDneg). Prior to chemotherapy MWI, MWE and CW were significantly lower in CTRCDmod than in CTRCDneg and CTRCDmild. Overt cardiac dysfunction in CTRCDmod at 6 months was accompanied by significant worse values in MWI, MWE and WW compared to CTRCDneg and CTRCDmild. MW features such as low baseline CW, especially when associated with a rise in WW at follow-up, may identify patients at risk for CTRCD. Additional studies are needed to explore the role of MW in CRTCD.

21 September 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Jürgen DuchenneJürgen Duchenne
Jürgen Duchenne
CLCamilla Kjellstad Larsen
Camilla Kjellstad Larsen
MCMarta Cvijić
Marta Cvijić
EGElena Galli
Elena Galli
JAJohn M. Aalen
John M. Aalen
JVJens-Uwe Voigt
Jens-Uwe Voigt
Background and aim: The presence of mechanical dyssynchrony on echocardiography is associated with reverse remodelling and decreased mortality after cardiac resynchronization therapy (CRT). Contrarily, myocardial scar reduces the effect of CRT. This study investigated how well a combined assessment of different markers of mechanical dyssynchrony and scarring identifies CRT responders. Methods: In a prospective multicentre study of 170 CRT recipients, septal flash (SF), apical rocking (ApRock), systolic stretch index (SSI), and lateral-to-septal (LW-S) work differences were assessed using echocardiography. Myocardial scarring was quantified using cardiac magnetic resonance imaging (CMR) or excluded based on a coronary angiogram and clinical history. The primary endpoint was a CRT response, defined as a ≥15% reduction in LV end-systolic volume 12 months after implantation. The secondary endpoint was time-to-death. Results: The combined assessment of mechanical dyssynchrony and septal scarring showed AUCs ranging between 0.81 (95%CI: 0.74–0.88) and 0.86 (95%CI: 0.79–0.91) for predicting a CRT response, without significant differences between the markers, but significantly higher than mechanical dyssynchrony alone. QRS morphology, QRS duration, and LV ejection fraction were not superior in their prediction. Predictive power was similar in the subgroups of patients with ischemic cardiomyopathy. The combined assessments significantly predicted all-cause mortality at 44 ± 13 months after CRT with a hazard ratio ranging from 0.28 (95%CI: 0.12–0.67) to 0.20 (95%CI: 0.08–0.49). Conclusions: The combined assessment of mechanical dyssynchrony and septal scarring identified CRT responders with high predictive power. Both visual and quantitative markers were highly feasible and demonstrated similar results. This work demonstrates the value of imaging LV mechanics and scarring in CRT candidates, which can already be achieved in a clinical routine.

20 November 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
CLCamilla Kjellstad Larsen
Camilla Kjellstad Larsen
OSOtto A. Smiseth
Otto A. Smiseth
Jürgen DuchenneJürgen Duchenne
Jürgen Duchenne
EGElena Galli
Elena Galli
JAJohn Moene Aalen
John Moene Aalen
EHEinar Hopp
Einar Hopp
Background: The response to cardiac resynchronization therapy (CRT) depends on septal viability and correction of abnormal septal motion. This study investigates if cardiac magnetic resonance (CMR) as a single modality can identify CRT responders with combined imaging of pathological septal motion (septal flash) and septal scar. Methods: In a prospective, multicenter, observational study of 136 CRT recipients, septal scar was assessed using late gadolinium enhancement (LGE) (n = 127) and septal flash visually from cine CMR sequences. The primary endpoint was CRT response, defined as ≥15% reduction in LV end-systolic volume with echocardiography after 6 months. The secondary endpoint was heart transplantation or death of any cause assessed after 39 ± 13 months. Results: Septal scar and septal flash were independent predictors of CRT response in multivariable analysis (both p < 0.001), while QRS duration and morphology were not. The combined approach of septal scar and septal flash predicted CRT response with an area under the curve of 0.86 (95% confidence interval (CI): 0.78–0.94) and was a strong predictor of long-term survival without heart transplantation (hazard ratio 0.27, 95% CI: 0.10–0.79). The accuracy of the approach was similar in the subgroup with intermediate (130–150 ms) QRS duration. The combined approach was superior to septal scar and septal flash alone (p < 0.01). Conclusions: The combined assessment of septal scar and septal flash using CMR as a single-image modality identifies CRT responders with high accuracy and predicts long-term survival.