The rapid technological developments of the past decade and the changes in echocardiographic practice brought about by these developments have resulted in the need for updated recommendations to the previously published guidelines for cardiac chamber quantification, which was the goal of the joint writing group assembled by the American Society of Echocardiography and the European Association of Cardiovascular Imaging. This document provides updated normal values for all four cardiac chambers, including three-dimensional echocardiography and myocardial deformation, when possible, on the basis of considerably larger numbers of normal subjects, compiled from multiple databases. In addition, this document attempts to eliminate several minor discrepancies that existed between previously published guidelines.
27 March 2018 in European Heart Journal - Cardiovascular Imaging
The EACVI/ASE/Industry Task Force to standardize deformation imaging prepared this consensus document to standardize definitions and techniques for using two-dimensional (2D) speckle tracking echocardiography (STE) to assess left atrial, right ventricular, and right atrial myocardial deformation. This document is intended for both the technical engineering community and the clinical community at large to provide guidance on selecting the functional parameters to measure and how to measure them using 2D STE. This document aims to represent a significant step forward in the collaboration between the scientific societies and the industry since technical specifications of the software packages designed to post-process echocardiographic datasets have been agreed and shared before their actual development. Hopefully, this will lead to more clinically oriented software packages which will be better tailored to clinical needs and will allow industry to save time and resources in their development.
26 September 2013 in New England Journal of Medicine
Dabigatran is an oral direct thrombin inhibitor that has been shown to be an effective alternative to warfarin in patients with atrial fibrillation. We evaluated the use of dabigatran in patients with mechanical heart valves. In this phase 2 dose-validation study, we studied two populations of patients: those who had undergone aortic- or mitral-valve replacement within the past 7 days and those who had undergone such replacement at least 3 months earlier. Patients were randomly assigned in a 2:1 ratio to receive either dabigatran or warfarin. The selection of the initial dabigatran dose (150, 220, or 300 mg twice daily) was based on kidney function. Doses were adjusted to obtain a trough plasma level of at least 50 ng per milliliter. The warfarin dose was adjusted to obtain an international normalized ratio of 2 to 3 or 2.5 to 3.5 on the basis of thromboembolic risk. The primary end point was the trough plasma level of dabigatran. The trial was terminated prematurely after the enrollment of 252 patients because of an excess of thromboembolic and bleeding events among patients in the dabigatran group. In the as-treated analysis, dose adjustment or discontinuation of dabigatran was required in 52 of 162 patients (32%). Ischemic or unspecified stroke occurred in 9 patients (5%) in the dabigatran group and in no patients in the warfarin group; major bleeding occurred in 7 patients (4%) and 2 patients (2%), respectively. All patients with major bleeding had pericardial bleeding. The use of dabigatran in patients with mechanical heart valves was associated with increased rates of thromboembolic and bleeding complications, as compared with warfarin, thus showing no benefit and an excess risk. (Funded by Boehringer Ingelheim; ClinicalTrials.gov numbers, NCT01452347 and NCT01505881.)
18 December 2014 in European Heart Journal - Cardiovascular Imaging
Recognizing the critical need for standardization in strain imaging, in 2010, the European Association of Echocardiography (now the European Association of Cardiovascular Imaging, EACVI) and the American Society of Echocardiography (ASE) invited technical representatives from all interested vendors to participate in a concerted effort to reduce intervendor variability of strain measurement. As an initial product of the work of the EACVI/ASE/Industry initiative to standardize deformation imaging, we prepared this technical document which is intended to provide definitions, names, abbreviations, formulas, and procedures for calculation of physical quantities derived from speckle tracking echocardiography and thus create a common standard.
1 March 2011 in Journal of the American Society of Echocardiography