Rabia Aziz

Ms. Rabia Aziz

University of Salerno, Fisciano, Italy
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
RARabia Aziz
Rabia Aziz
MFMariarosaria Falanga
Mariarosaria Falanga
JPJelena Purenovic
Jelena Purenovic
Simona ManciniSimona Mancini
Simona Mancini
Patrizia LambertiPatrizia Lamberti
Patrizia Lamberti
Michele GuidaMichele Guida
Michele Guida
As cardiac diseases, which mostly result in heart failure, are increasing rapidly worldwide, heart transplantation seems the only solution for saving lives. However, this practice is not always possible due to several reasons, such as scarcity of donors, rejection of organs from recipient bodies, or costly medical procedures. In the framework of nanotechnology, nanomaterials greatly contribute to the development of these cardiovascular scaffolds as they provide an easy regeneration of the tissues. Currently, functional nanofibers can be used in the production of stem cells and in the regeneration of cells and tissues. The small size of nanomaterials, however, leads to changes in their chemical and physical characteristics that could alter their interaction and exposure to stem cells with cells and tissues. This article aims to review the naturally occurring biodegradable nanomaterials that are used in cardiovascular tissue engineering for the development of cardiac patches, vessels, and tissues. Moreover, this article also provides an overview of cell sources used for cardiac tissue engineering, explains the anatomy and physiology of the human heart, and explores the regeneration of cardiac cells and the nanofabrication approaches used in cardiac tissue engineering as well as scaffolds.


25 November 2024 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
RARabia Aziz
Rabia Aziz
JMJens Maebe
Jens Maebe
FMFlorence Marie Muller
Florence Marie Muller
YDYves D’aSseler
Yves D’aSseler
SVStefaan Vandenberghe
Stefaan Vandenberghe
Long-axial field-of-view (LAFOV) Positron Emission Tomography (PET) scanners provide high sensitivity, but throughput is limited because of time-consuming patient positioning. To enhance throughput, a novel Walk-Through PET (WT-PET) scanner has been developed, allowing patients to stand upright, supported by an adjustable headrest and hand supports. This study evaluates the degree of motion in the WT-PET system and compares it with the standard PET-CT. Three studies were conducted with healthy volunteers to estimate motion. The first two studies assessed motion in the WT-PET’s Design I (Study 1) and Design II (Study 2), while the third study compared motion on a standard PET-CT scanner bed (Study 3). Infrared markers placed on the head, shoulders, chest, and abdomen were tracked and processed using image-processing techniques involving thresholding and connected component analysis. Videos were recorded for normal breathing and breath-holding conditions, and 2D centroids were transformed into 3D coordinates using depth information. The results shows a significant reduction in motion during breath-holding, especially for the abdomen. Mean motion distances decreased from 2.63 mm to 2.18 mm in Study 1 and from 2.42 mm to 1.67 mm in Study 2. Statistical analysis revealed notable differences in motion between the WT-PET and mCT scanners. The Shapiro-Wilk test indicated non-normal motion distributions in the head, right shoulder, and abdomen for both systems, leading to the use of the Wilcoxon signed-rank test for all markers. Significant differences were found in the right shoulder (p = 0.0266), left shoulder (p = 0.0004) and chest (p < 0.0001) but no significant differences were observed in the head (p = 0.1327) and abdomen (p = 0.8404). This study provides a comprehensive analysis of patient motion in a WT-PET scanner with respect to the standard PET. The findings highlight a significant increase in shoulder and chest motion, while the head and abdomen regions showed more stability.

27 November 2025 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
RARabia Aziz
Rabia Aziz
FMFlorence Marie Muller
Florence Marie Muller
NWNadia Withofs
Nadia Withofs
JMJens Maebe
Jens Maebe
MDMeysam Dadgar
Meysam Dadgar
SVStefaan Vandenberghe
Stefaan Vandenberghe
The novel upright walk-through PET (WT-PET) scanner enhances patient throughput compared to the conventional cylindrical PET systems but introduces unique