Meysam Dadgar

Meysam Dadgar

Auto-generated profile, based on publicly available information

Meysam Dadgar


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2024 in Science Advances
Verified
Journal Article
Open access
PMPawel Moskal
Pawel Moskal
JBJakub Baran
Jakub Baran
SBSteven Bass
Steven Bass
JCJarosław Choiński
Jarosław Choiński
NCNeha Chug
Neha Chug
Ewa Łucja StępieńEwa Łucja Stępień
Ewa Łucja Stępień
Positronium is abundantly produced within the molecular voids of a patient’s body during positron emission tomography (PET). Its properties dynamically respond to the submolecular architecture of the tissue and the partial pressure of oxygen. Current PET systems record only two annihilation photons and cannot provide information about the positronium lifetime. This study presents the in vivo images of positronium lifetime in a human, for a patient with a glioblastoma brain tumor, by using the dedicated Jagiellonian PET system enabling simultaneous detection of annihilation photons and prompt gamma emitted by a radionuclide. The prompt gamma provides information on the time of positronium formation. The photons from positronium annihilation are used to reconstruct the place and time of its decay. In the presented case study, the determined positron and positronium lifetimes in glioblastoma cells are shorter than those in salivary glands and those in healthy brain tissues, indicating that positronium imaging could be used to diagnose disease in vivo.

11 October 2023 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
MDM. Dadgar
M. Dadgar
SPS. Parzych
S. Parzych
JBJ. Baran
J. Baran
NCN. Chug
N. Chug
CCC. Curceanu
C. Curceanu
PMPawel Moskal
Pawel Moskal
Background: Alongside the benefits of Total-Body imaging modalities, such as higher sensitivity, single-bed position, low dose imaging, etc., their final construction cost prevents worldwide utilization. The main aim of this study is to present a simulation-based comparison of the sensitivities of existing and currently developed tomographs to introduce a cost-efficient solution for constructing a Total-Body PET scanner based on plastic scintillators. Methods: For the case of this study, eight tomographs based on the uEXPLORER configuration with different scintillator materials (BGO, LYSO), axial field-of-view (97.4 cm and 194.8 cm), and detector configurations (full and sparse) were simulated. In addition, 8 J-PET scanners with different configurations, such as various axial field-of-view (200 cm and 250 cm), different cross sections of plastic scintillator, and multiple numbers of plastic scintillator layers (2, 3, and 4), based on J-PET technology have been simulated by GATE software. Furthermore, Siemens’ Biograph Vision has been simulated to compare the results with standard PET scans. Two types of simulations have been performed. The first one with a centrally located source with a diameter of 1 mm and a length of 250 cm, and the second one with the same source inside a water-filled cylindrical phantom with a diameter of 20 cm and a length of 183 cm. Results: With regards to sensitivity, among all the proposed scanners, the ones constructed with BGO crystals give the best performance ( $$\sim$$ ∼ 350 cps/kBq at the center). The utilization of sparse geometry or LYSO crystals significantly lowers the achievable sensitivity of such systems. The J-PET design gives a similar sensitivity to the sparse LYSO crystal-based detectors while having full detector coverage over the body. Moreover, it provides uniform sensitivity over the body with additional gain on its sides and provides the possibility for high-quality brain imaging. Conclusion: Taking into account not only the sensitivity but also the price of Total-Body PET tomographs, which till now was one of the main obstacles in their widespread clinical availability, the J-PET tomography system based on plastic scintillators could be a cost-efficient alternative for Total-Body PET scanners.

1 December 2023 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
MDMeysam Dadgar
Meysam Dadgar
JMJens Maebe
Jens Maebe
MAMaya Abi Akl
Maya Abi Akl
BVBoris Vervenne
Boris Vervenne
SVStefaan Vandenberghe
Stefaan Vandenberghe
Background: Although a new generation of tomographs with a longer axial field-of-view called total-body PET have been developed, they are not widely utilized due to their high cost compared to conventional scanners. The newly designed walk-through total-body PET scanner is introduced as a high-throughput and cost-efficient alternative to total-body PET scanners, by making use of a flat panel geometry and lower cost, depth-of-interaction capable, monolithic BGO detectors. The main aim of the presented study is to evaluate through Monte Carlo simulation the system characteristics of the walk-through total-body PET scanner by comparing it with a Quadra-like total-body PET of similar attributes to the Siemens Biograph Vision Quadra. Methods: The walk-through total-body PET is comprised of two flat detector panels, spaced 50 cm apart. Each panel, 70 $$\times$$ × 106 cm $$^2$$ 2 in size, consists of 280 BGO-based monolithic detectors. The Quadra-like TB-PET has been simulated based on the characteristics of the Biograph Vision Quadra, one of the most common total-body PET scanners with 106 cm of axial field-of-view, which is constructed with pixelated LSO scintillation crystals. The spatial resolution, sensitivity, count rate performance, scatter fractions, and image quality of both scanners are simulated in the GATE simulation toolkit for comparison. Results: Due to the DOI-capable detectors used in the walk-through total-body PET, the values of the spatial resolution of this scanner were all below 2 mm along directions parallel to the panels, and reached a maximum of 3.36 mm in the direction perpendicular to the panels. This resolution is a large improvement compared to the values of the Quadra-like TB-PET. The walk-through total-body PET uses its maximum sensitivity (154 cps/kBq) for data acquisition and image reconstruction. Conclusion: Based on the combination of very good spatial resolution and high sensitivity of the walk-through total-body PET, along with a 2.2 times lower scintillation crystal volume and 1.8 times lower SiPM surface, this scanner can be a very cost-efficient alternative for total-body PET scanners in cases where concomitant CT is not required.

1 January 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
PMPawel Moskal
Pawel Moskal
TBTomasz Krzysztof Bednarski
Tomasz Krzysztof Bednarski
SNSzymon Niedźwiecki
Szymon Niedźwiecki
MSMichal Silarski
Michal Silarski
ECEryk Czerwiński
Eryk Czerwiński
BZBożena Katarzyna Zgardzińska
Bożena Katarzyna Zgardzińska
Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a full-scale J-PET tomograph from long strips of plastic scintillators, a 24-strip prototype was built and tested. The prototype consists of detection modules arranged axially forming a cylindrical diagnostic chamber with the inner diameter of 360 mm and the axial field-of-view of 300 mm. Promising perspectives for a low-cost construction of a total-body PET scanner are opened due to an axial arrangement of strips of plastic scintillators, wchich have a small light attenuation, superior timing properties, and the possibility of cost-effective increase of the axial field-of-view. The presented prototype comprises dedicated solely digital front-end electronic circuits and a triggerless data acquisition system which required development of new calibration methods including time, thresholds and gain synchronization. The system and elaborated calibration methods including first results of the 24-module J-PET prototype are presented and discussed. The achieved coincidence resolving time equals to CRT = 490 ± 9 ps. This value can be translated to the position reconstruction accuracy σ(Δ) = 18 mm which is fairly position-independent Keywords: positron emission tomography, plastic scintillators, J-PET.

16 October 2024 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
MDMeysam Dadgar
Meysam Dadgar
AVAmaryllis Verstraete
Amaryllis Verstraete
JMJens Maebe
Jens Maebe
YDYves D’asseler
Yves D’asseler
SVStefaan Vandenberghe
Stefaan Vandenberghe
This study investigates the integration of Artificial Intelligence (AI) in compensating the lack of time-of-flight (TOF) of the GE Omni Legend PET/CT, which utilizes BGO scintillation crystals. The current study evaluates the image quality of the GE Omni Legend PET/CT using a NEMA IQ phantom. It investigates the impact on imaging performance of various deep learning precision levels (low, medium, high) across different data acquisition durations. Quantitative analysis was performed using metrics such as contrast recovery coefficient (CRC), background variability (BV), and contrast to noise Ratio (CNR). Additionally, patient images reconstructed with various deep learning precision levels are presented to illustrate the impact on image quality. The deep learning approach significantly reduced background variability, particularly for the smallest region of interest. We observed improvements in background variability of 11.8 $$\%$$ , 17.2 $$\%$$ , and 14.3 $$\%$$ for low, medium, and high precision deep learning, respectively. The results also indicate a significant improvement in larger spheres when considering both background variability and contrast recovery coefficient. The high precision deep learning approach proved advantageous for short scans and exhibited potential in improving detectability of small lesions. The exemplary patient study shows that the noise was suppressed for all deep learning cases, but low precision deep learning also reduced the lesion contrast (about −30 $$\%$$ ), while high precision deep learning increased the contrast (about 10 $$\%$$ ). This study conducted a thorough evaluation of deep learning algorithms in the GE Omni Legend PET/CT scanner, demonstrating that these methods enhance image quality, with notable improvements in CRC and CNR, thereby optimizing lesion detectability and offering opportunities to reduce image acquisition time.

4 October 2022 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
MDM. Dadgar
M. Dadgar
SPS. Parzych
S. Parzych
FAF. Tayefi Ardebili
F. Tayefi Ardebili
JBJ. Baran
J. Baran
NCN. Chug
N. Chug
PMPawel Moskal
Pawel Moskal
The growing interest in human-grade Total Body PET systems has also application in small animal research. Due to the existing limitations in human-based studies involving drug development and novel treatment monitoring, animalbased research became a necessary step for testing and protocol preparation. In this simulation-based study two unconventional, cost effective small animal Total Body PET scanners (for mouse and rat studies) have been investigated in order to inspect their feasibility for preclinical research. They were designed with the novel technology explored by the Jagiellonian PET Collaboration (J-PET). Two main PET characteristics: sensitivity and spatial resolution were mainly inspected to evaluate their performance. Moreover, the impact of the scintillator dimension and time-offlight on the latter parameter were examined in order to design the most efficient tomographs. The presented results show that for mouse TB J-PET the achievable system sensitivity is equal to 2.35% and volumetric spatial resolution to 9.46 ± 0.54 mm3, while for rat TB J-PET they are equal to 2.6% and 14.11 ± 0.80 mm3, respectively. Furthermore, it was shown that the designed tomographs are almost parallax-free systems, hence they resolve the problem of the acceptance criterion trade-off between enhancing spatial resolution and reducing sensitivity.