Xinhua Wan

Xinhua Wan


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2022 in Military Medical Research
Verified
Journal Article
Open access
PDF file
Binfeng YinBinfeng Yin
Binfeng Yin
XWXinhua Wan
Xinhua Wan
MYMingzhu Yang
Mingzhu Yang
CQChang-Cheng Qian
Chang-Cheng Qian
A S M Muhtasim Fuad SohanA S M Muhtasim Fuad Sohan
A S M Muhtasim Fuad Sohan
Background: Early diagnosis and classification of infections increase the cure rate while decreasing complications, which is significant for severe infections, especially for war surgery. However, traditional methods rely on laborious operations and bulky devices. On the other hand, point-of-care (POC) methods suffer from limited robustness and accuracy. Therefore, it is of urgent demand to develop POC devices for rapid and accurate diagnosis of infections to fulfill on-site militarized requirements. Methods: We developed a wave-shaped microfluidic chip (WMC) assisted multiplexed detection platform (WMC-MDP). WMC-MDP reduces detection time and improves repeatability through premixing of the samples and reaction of the reagents. We further combined the detection platform with the streptavidin–biotin (SA-B) amplified system to enhance the sensitivity while using chemiluminescence (CL) intensity as signal readout. We realized simultaneous detection of C-reactive protein (CRP), procalcitonin (PCT), and interleukin-6 (IL-6) on the detection platform and evaluated the sensitivity, linear range, selectivity, and repeatability. Finally, we finished detecting 15 samples from volunteers and compared the results with commercial ELISA kits. Results: Detection of CRP, PCT, and IL-6 exhibited good linear relationships between CL intensities and concentrations in the range of 1.25–40 μg/ml, 0.4–12.8 ng/ml, and 50–1600 pg/ml, respectively. The limit of detection of CRP, PCT, and IL-6 were 0.54 μg/ml, 0.11 ng/ml, and 16.25 pg/ml, respectively. WMC-MDP is capable of good adequate selectivity and repeatability. The whole detection procedure takes only 22 min that meets the requirements of a POC device. Results of 15 samples from volunteers were consistent with the results detected by commercial ELISA kits. Conclusions: WMC-MDP allows simultaneous, rapid, and sensitive detection of CRP, PCT, and IL-6 with satisfactory selectivity and repeatability, requiring minimal manipulation. However, WMC-MDP takes advantage of being a microfluidic device showing the coefficients of variation less than 10% enabling WMC-MDP to be a type of point-of-care testing (POCT). Therefore, WMC-MDP provides a promising alternative to POCT of multiple biomarkers. We believe the practical application of WMC-MDP in militarized fields will revolutionize infection diagnosis for soldiers.

10 November 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
Binfeng YinBinfeng Yin
Binfeng Yin
XWXinhua Wan
Xinhua Wan
CQChangcheng Qian
Changcheng Qian
A S M Muhtasim Fuad SohanA S M Muhtasim Fuad Sohan
A S M Muhtasim Fuad Sohan
Teng ZhouTeng Zhou
Teng Zhou
WYWenkai Yue
Wenkai Yue
Metal ions in high concentrations can pollute the marine environment. Human activities and industrial pollution are the causes of Cu2+ contamination. Here, we report our discovery of an enzyme method-based microfluidic that can be used to rapidly detect Cu2+ in seawater. In this method, Cu2+ is reduced to Cu+ to inhibit horseradish peroxidase (HRP) activity, which then results in the color distortion of the reaction solution. The chip provides both naked eye and spectrophotometer modalities. Cu2+ concentrations have an ideal linear relationship, with absorbance values ranging from 3.91 nM to 256 μM. The proposed enzyme method-based microfluidic chip detects Cu2+ with a limit of detection (LOD) of 0.87 nM. Other common metal ions do not affect the operation of the chip. The successful detection of Cu2+ was achieved using three real seawater samples, verifying the ability of the chip in practical applications. Furthermore, the chip realizes the functions of two AND gates in series and has potential practical implementations in biochemical detection and biological computing.

28 June 2024 in Foods
Verified
Journal Article
Open access
PDF file
JLJun Liu
Jun Liu
SZShiyu Zeng
Shiyu Zeng
HZHaoyu Zhu
Haoyu Zhu
XWXinhua Wan
Xinhua Wan
A S M Muhtasim Fuad SohanA S M Muhtasim Fuad Sohan
A S M Muhtasim Fuad Sohan
Binfeng YinBinfeng Yin
Binfeng Yin
Food safety requires point-of-care testing (POCT) for mycotoxins, since their presence in wine significantly impacts the wine industry and poses a severe threat to human life. Traditional detection methods are usually limited to detecting one mycotoxin and cannot achieve high-throughput, automated, and rapid quantitative analysis of multiple mycotoxins in real samples. Here, we propose a portable automated microfluidic platform (PAMP) integrating a chemiluminescence (CL) imaging system and a microfluidic chip to realize POCT for multiple mycotoxins in real samples, simplifying complex manual operations, shortening the detection time, and improving the detection sensitivity. Specially, silicone films were used as substrates on microfluidic chips to incubate mycotoxin conjugations, and the streptavidin–biotin (SA-B) system and an indirect immunoassay were implemented on silicone films to improve the sensitivity of reaction results. Interestingly, these methods significantly improved detection results, resulting in sensitive detection of mycotoxins, including zearalenone (ZEA) ranging from 1 to 32 ng/mL, aflatoxin B1 (AFB1) ranging from 0.2 to 6.4 ng/mL, and ochratoxin A (OTA) ranging from 2 to 64 ng/mL. The recovery of samples reached 91.39–109.14%, which verified the reliability and practicability of the PAMP. This PAMP enables sensitive and rapid detection of multiple mycotoxins in markets or wineries that lack advanced laboratory facilities. Therefore, it is essential to develop a portable microfluidic platform for POCT to detect mycotoxins in real samples.