Mingzhu Yang

Dr. Mingzhu Yang

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017 in Science Advances
Verified
Journal Article
Open access
PDF file
MYMingzhu Yang
Mingzhu Yang
WZWei Zhang
Wei Zhang
JYJunchuan Yang
Junchuan Yang
BHBinfeng Hu
Binfeng Hu
FCFengjing Cao
Fengjing Cao
XJXingyu Jiang
Xingyu Jiang
Stacked paper skiving paves the way for industrial manufacturing of paper-based analytical devices for barcode assays.

29 April 2024 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
ZDZaizai Dong
Zaizai Dong
YWYusen Wang
Yusen Wang
GXGaolian Xu
Gaolian Xu
BLBing Liu
Bing Liu
YWYang Wang
Yang Wang
LCLingqian Chang
Lingqian Chang
Accurate prediction of the efficacy of immunotherapy for cancer patients through the characterization of both genetic and phenotypic heterogeneity in individual patient cells holds great promise in informing targeted treatments, and ultimately in improving care pathways and clinical outcomes. Here, we describe the nanoplatform for interrogating living cell host-gene and (micro-)environment (NICHE) relationships, that integrates micro- and nanofluidics to enable highly efficient capture of circulating tumor cells (CTCs) from blood samples. The platform uses a unique nanopore-enhanced electrodelivery system that efficiently and rapidly integrates stable multichannel fluorescence probes into living CTCs for in situ quantification of target gene expression, while on-chip coculturing of CTCs with immune cells allows for the real-time correlative quantification of their phenotypic heterogeneities in response to immune checkpoint inhibitors (ICI). The NICHE microfluidic device provides a unique ability to perform both gene expression and phenotypic analysis on the same single cells in situ, allowing us to generate a predictive index for screening patients who could benefit from ICI. This index, which simultaneously integrates the heterogeneity of single cellular responses for both gene expression and phenotype, was validated by clinically tracing 80 non–small cell lung cancer patients, demonstrating significantly higher AUC (area under the curve) (0.906) than current clinical reference for immunotherapy prediction.

11 February 2022 in Military Medical Research
Verified
Journal Article
Open access
PDF file
Binfeng YinBinfeng Yin
Binfeng Yin
XWXinhua Wan
Xinhua Wan
MYMingzhu Yang
Mingzhu Yang
CQChang-Cheng Qian
Chang-Cheng Qian
A S M Muhtasim Fuad SohanA S M Muhtasim Fuad Sohan
A S M Muhtasim Fuad Sohan
Background: Early diagnosis and classification of infections increase the cure rate while decreasing complications, which is significant for severe infections, especially for war surgery. However, traditional methods rely on laborious operations and bulky devices. On the other hand, point-of-care (POC) methods suffer from limited robustness and accuracy. Therefore, it is of urgent demand to develop POC devices for rapid and accurate diagnosis of infections to fulfill on-site militarized requirements. Methods: We developed a wave-shaped microfluidic chip (WMC) assisted multiplexed detection platform (WMC-MDP). WMC-MDP reduces detection time and improves repeatability through premixing of the samples and reaction of the reagents. We further combined the detection platform with the streptavidin–biotin (SA-B) amplified system to enhance the sensitivity while using chemiluminescence (CL) intensity as signal readout. We realized simultaneous detection of C-reactive protein (CRP), procalcitonin (PCT), and interleukin-6 (IL-6) on the detection platform and evaluated the sensitivity, linear range, selectivity, and repeatability. Finally, we finished detecting 15 samples from volunteers and compared the results with commercial ELISA kits. Results: Detection of CRP, PCT, and IL-6 exhibited good linear relationships between CL intensities and concentrations in the range of 1.25–40 μg/ml, 0.4–12.8 ng/ml, and 50–1600 pg/ml, respectively. The limit of detection of CRP, PCT, and IL-6 were 0.54 μg/ml, 0.11 ng/ml, and 16.25 pg/ml, respectively. WMC-MDP is capable of good adequate selectivity and repeatability. The whole detection procedure takes only 22 min that meets the requirements of a POC device. Results of 15 samples from volunteers were consistent with the results detected by commercial ELISA kits. Conclusions: WMC-MDP allows simultaneous, rapid, and sensitive detection of CRP, PCT, and IL-6 with satisfactory selectivity and repeatability, requiring minimal manipulation. However, WMC-MDP takes advantage of being a microfluidic device showing the coefficients of variation less than 10% enabling WMC-MDP to be a type of point-of-care testing (POCT). Therefore, WMC-MDP provides a promising alternative to POCT of multiple biomarkers. We believe the practical application of WMC-MDP in militarized fields will revolutionize infection diagnosis for soldiers.

25 September 2023 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
LJLiying Jiang
Liying Jiang
XLXianghao Lan
Xianghao Lan
LRLinjiao Ren
Linjiao Ren
ZJZhiyuan Jin
Zhiyuan Jin
Xuchen ShanXuchen Shan
Xuchen Shan
LCLingqian Chang
Lingqian Chang
To minimize and control the transmission of infectious diseases, a sensitive, accurate, rapid, and robust assay strategy for application on-site screening is critical. Here, we report single-molecule RNA capture-assisted digital RT-LAMP (SCADL) for point-of-care testing of infectious diseases. Target RNA was captured and enriched by specific capture probes and oligonucleotide probes conjugated to magnetic beads, replacing laborious RNA extraction. Droplet generation, amplification, and the recording of results are all integrated on a microfluidic chip. In assaying commercial standard samples, quantitative results precisely corresponded to the actual concentration of samples. This method provides a limit of detection of 10 copies mL−1 for the N gene within 1 h, greatly reducing the need for skilled personnel and precision instruments. The ultrasensitivity, specificity, portability, rapidity and user-friendliness make SCADL a competitive candidate for the on-site screening of infectious diseases.

1 November 2012 in Chinese Physics C
Verified
Journal Article
Closed access
PDF file
MAM. Ablikim
M. Ablikim
JBJ. Z. Bai
J. Z. Bai
YBY. Bai
Y. Bai
YBY. Ban
Y. Ban
XCXinchen Cai
Xinchen Cai
Bing-Song ZouBing-Song Zou
Bing-Song Zou
Based on 58 million J/ψ events collected by the BES II detector at the BEPC, J/ψ → Λ π+π− is observed for the first time. The branching fraction is measured to be Br(J/ψ → Λ π+π−) = (4.30±0.13±0.99)×10−3, excluding the decays to intermediate states, namely J/ψ → Ξ−+, J/ψ → Σ(1385)−(1385)+, and J/ψ → Σ(1385)+(1385)−. The branching fractions for these intermediate resonance channels are measured to be: Br(J/ψ → Ξ−+) = (0.90±0.03±0.18)×10−3, Br(J/ψ → Σ(1385)−(1385)+) = (1.23±0.07±0.30)×10−3, and Br(J/ψ → Σ(1385)+(1385)−) = (1.50±0.08±0.38)×10−3, respectively. The angular distribution is of the form ∝ (1 + αcos2θ) with α = (0.35±0.29±0.06) for J/ψ → Ξ−+, α = (−0.54±0.22±0.10) for J/ψ → Σ(1385)−(1385)+, and α = (−0.35±0.25±0.06) for J/ψ → Σ(1385)+(1385)−.

19 May 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
LJLiying Jiang
Liying Jiang
XLXianghao Lan
Xianghao Lan
RLRen Linjiao
Ren Linjiao
MYMingzhu Yang
Mingzhu Yang
BWBo Wei
Bo Wei
Yang WangYang Wang
Yang Wang
Loop-mediated isothermal amplification (LAMP) is a rapid and high-yield amplification technology for specific DNA or RNA molecules. In this study, we designed a digital loop-mediated isothermal amplification (digital-LAMP)-functioning microfluidic chip to achieve higher sensitivity for detection of nucleic acids. The chip could generate droplets and collect them, based on which we could perform Digital-LAMP. The reaction only took 40 min at a constant temperature of 63 °C. The chip enabled highly accurate quantitative detection, with the limit of detection (LOD) down to 102 copies μL−1. For better performance while reducing the investment of money and time in chip structure iterations, we used COMSOL Multiphysics to simulate different droplet generation ways by including flow-focusing structure and T-junction structure. Moreover, the linear structure, serpentine structure, and spiral structure in the microfluidic chip were compared to study the fluid velocity and pressure distribution. The simulations provided a basis for chip structure design while facilitating chip structure optimization. The digital-LAMP-functioning chip proposed in the work provides a universal platform for analysis of viruses.