Yuan Liu

Yuan Liu


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2019 in Brain Imaging and Behavior
Verified
Journal Article
Open access
PDF file
QSQing Sun
Qing Sun
WFWenliang Fan
Wenliang Fan
YLYuan Liu
Yuan Liu
YZYan Zou
Yan Zou
NWNatalie Wiseman
Natalie Wiseman
PHPing Han
Ping Han
Cirrhosis is a major public health concern. However, little is known about the neurobiological mechanisms underlying brain microstructure alterations in cirrhotic patients. The purpose of this prospective study was to investigate brain microstructural alterations in cirrhosis with or without minimal hepatic encephalopathy (MHE) and their relationship with patients’ neurocognitive performance and disease duration using voxel-based analysis of diffusion kurtosis imaging (DKI). DKI data were acquired from 30 cirrhotic patients with MHE, 31 patients without MHE (NMHE) and 59 healthy controls. All DKI-derived parametric maps were compared across the three groups to investigate their group differences. Correlation analyses were further performed to assess relationships between altered imaging parameters and clinical data. Voxel-based analysis of DKI data results showed that MHE/NMHE patients had increased radial diffusivity, axial diffusivity (AD) and mean diffusivity in addition to decreased axial kurtosis (AK) and fractional anisotropy of kurtosis in several regions. Compared to controls, these regions were primarily the cingulum, temporal and frontal cortices. The DKI metrics (i.e., AK and AD) were correlated with clinical variables in the two patient groups. In conclusion, DKI is useful for detecting brain microstructural abnormalities in MHE and NMHE patients. Abnormal DKI parameters suggest alterations in brain microstructural complexity in cirrhotic patients, which may contribute to the neurobiological basis of neurocognitive impairment. These results may provide additional information on the pathophysiology of cirrhosis.

7 November 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
JTJuan Tao
Juan Tao
Hao LiaoHao Liao
Hao Liao
YLYuan Liu
Yuan Liu
QPQingsong Peng
Qingsong Peng
WZWenying Zhu
Wenying Zhu
FYFan Yang
Fan Yang
Objectives: To compare the application value of digital breast tomosynthesis (DBT) and full-field digital mammography (FFDM) in breast galactography. Materials and Methods: A total of 128 patients with pathological nipple discharge (PND) were selected to undergo galactography. DBT and FFDM were performed for each patient after injecting the contrast agent; the radiation dose of DBT and FFDM was calculated, and the image quality was evaluated in consensus by two senior breast radiologists. Histopathologic data were found in 49 of the 128 patients. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for both FFDM- and DBT-galactography were calculated using histopathologic results as a reference standard. Data were presented as percentages along with their 95% confidence intervals (CI). Results: The average age of the 128 patients was 46.53 years. The average glandular dose (AGD) of DBT-galactography was slightly higher than that of FFDM-galactography (p < 0.001). DBT-galactography was 30.7% higher than FFDM-galactography in CC view, while DBT-galactography increased by 21.7% compared with FFDM-galactography in ML view. Regarding catheter anatomic distortion, structure detail, and overall image quality groups, DBT scores were higher than FFDM scores, and the differences were significant for all measures (p < 0.05). In 49 patients with pathological nipple discharge, we found that the DBT-galactography had higher sensitivity, specificity, PPV, and NPV (93.3%, 75%, 97.7%, and 50%, respectively) than FFDM-galactography (91.1%, 50%, 95.3%, and 33.3%, respectively). Conclusions: Compared to FFDM-galactography, within the acceptable radiation dose range, DBT-galactography increases the sensitivity and specificity of lesion detection by improving the image quality, providing more confidence for the diagnosis of clinical ductal lesions.