Wenying Zhu

Prof. Wenying Zhu

working
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
SPShuyi Peng
Shuyi Peng
LCLeqing Chen
Leqing Chen
JTJuan Tao
Juan Tao
JLJie Liu
Jie Liu
WZWenying Zhu
Wenying Zhu
FYFan Yang
Fan Yang
Objective: To explore whether the pretreatment dynamic contrast enhancement magnetic resonance imaging (DCE-MRI) and radiomics signatures were associated with pathologic complete response (pCR) to neoadjuvant therapy (NAT) in breast cancer. Method: A retrospective review of 70 patients with breast invasive carcinomas proved by biopsy between June 2017 and October 2020 (26 patients were pathological complete response, and 44 patients were non-pathological complete response). Within the pre-contrast and five post-contrast dynamic series, a total of 1037 quantitative imaging features were extracted from in each phase. Additionally, the Δfeatures (the difference between the features before and after the comparison) were used for subsequent analysis. The least absolute shrinkage and selection operator (LASSO) regression method was used to select features related to pCR, and then use these features to train multiple machine learning classifiers to predict the probability of pCR for a given patient. The area under the curve (AUC), accuracy, sensitivity, and specificity were calculated to assess the predictive performances of the radiomics model for each of the five phases of time points. Result: Among the five phases, each individual phase performed with AUCs ranging from 0.845 to 0.919 in predicting pCR. The best single phases performance was given by the 3rd phase (AUC = 0.919, sensitivity 0.885, specificity 0.864). 5 of the features have significant differences between pCR and non-pCR groups in each phase, most features reach their maximum or minimum in the 2nd or 3rd phase. Conclusion: The radiomic features extracted from each phase of pre-treatment DCE-MRI possess discriminatory power to predict tumor response.

4 December 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
SPShuyi Peng
Shuyi Peng
YGYihao Guo
Yihao Guo
XZXiaoyong Zhang
Xiaoyong Zhang
JTJuan Tao
Juan Tao
JLJie Liu
Jie Liu
FYFan Yang
Fan Yang
To investigate the feasibility and effectiveness of high-resolution readout-segmented echo planar imaging (rs-EPI), diffusion-weighted imaging (DWI) is used simultaneously with multi-slice (SMS) imaging (SMS rs-EPI) for the differentiation of breast malignant and benign lesions in comparison to conventional rs-EPI on a 3T MR scanner. A total of 102 patients with 113 breast lesions underwent bilateral breast MRI using a prototype SMS rs-EPI sequence and a conventional rs-EPI sequence. Subjective image quality was assessed using a 5-point Likert scale (1 = poor, 5 = excellent). Signal-to-noise ratio (SNR), lesion contrast-to-noise ratio (CNR) and apparent diffusion coefficients (ADC) value of the lesion were measured for comparison. Receiver operating characteristic curve analysis was performed to evaluate the diagnosis performance of ADC, and the corresponding area under curve (AUC) was calculated. The image quality scores in anatomic distortion, lesion conspicuity, sharpness of anatomical details and overall image quality of SMS rs-EPI were significantly higher than those of conventional rs-EPI. CNR was enhanced in the high-resolution SMS rs-EPI acquisition (6.48 ± 1.71 vs. 4.23 ± 1.49; p < 0.001). The mean ADC value was comparable in SMS rs-EPI and conventional rs-EPI (benign 1.45 × 10−3 vs. 1.43 × 10−3 mm2/s, p = 0.702; malignant 0.91 × 10−3 vs. 0.89 × 10−3 mm2/s, p = 0.076). The AUC was 0.957 in SMS rs-EPI and 0.983 in conventional rs-EPI. SMS rs-EPI technique allows for higher spatial resolution and slight reduction of scan time in comparison to conventional rs-EPI, which has potential for better differentiation between malignant and benign lesions of the breast.

24 March 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
SPShuyi Peng
Shuyi Peng
PSPeng Sun
Peng Sun
JLJie Liu
Jie Liu
JTJuan Tao
Juan Tao
WZWenying Zhu
Wenying Zhu
FYFan Yang
Fan Yang
Objectives: To explore the feasibility of time-dependent diffusion in clinical applications of breast MRI, as well as the capacity of quantitative microstructural mapping for characterizing the cellular properties in malignant and benign breast tumors. Methods: 38 patients with 45 lesions were enrolled. Diffusion MRI acquisition was conducted with a combination of pulsed gradient spin-echo sequences (PGSE) and oscillating gradient spin-echo (OGSE) on a 3T MRI scanner. The microstructural parameters including cellularity extracellular diffusivity (Dex), mean cell size, intracellular volume fraction (νin), and the apparent diffusion coefficient (ADC) values were calculated. Each parameter was compared using the unpaired t-test between malignant and benign tumors. The area under the receiver operating characteristic curve (AUC) values was used to evaluate the diagnostic performance of different indices. Results: The mean diameter, Dex, ADC0Hz, ADC25Hz, and ADC50Hz were significantly lower in the malignant group than in the benign group (p < 0.001), while νin and cellularity were significantly higher in the malignant group (p < 0.001). All the microstructural parameters and time-dependent ADC values achieved high accuracy in differentiating between malignant and benign tumors of the breast. For microstructural parameters, the AUC of the cellularity was greater than others (AUC = 0.936). In an immunohistochemical subgroup comparison, the PR-positive group had significantly lower νin and cellularity, and significantly elevated Dex and ADC0Hz compared to the negative groups (p < 0.05). When combining diffusion parameters (cellularity, diameter, and ADC25Hz), the highest diagnostic performance was obtained with an AUC of 0.969. Conclusions: DWI with a short diffusion time is capable of providing additional microstructural parameters in differentiating between benign and malignant breast tumors. The time-dependent diffusion MRI parameters have the potential to serve as a non-invasive tool to probe the differences in the internal structures of breast lesions.

1 December 2021 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
PDF file
YWYingliang Wang
Yingliang Wang
SSSonglin Song
Songlin Song
CZChen Zhou
Chen Zhou
WZWenying Zhu
Wenying Zhu
JLJiacheng Liu
Jiacheng Liu
BXBin Xiong
Bin Xiong
Purpose: To evaluate the safety and efficacy of thoracic endovascular aortic repair (TEVAR) for retrograde type A intramural hematoma (IMH) with intimal disruption in the descending aorta and report our endovascular therapeutic experience. Materials and Methods: From January 2014 to October 2020, a total of 24 consecutive patients with retrograde type A IMH with intimal disruption (intimal tear or ulcer-like projection) in the descending aorta underwent TEVAR. The demographics, clinical characteristics, treatment details, imaging information, and follow-up results were reviewed. Results: Among all patients with retrograde type A IMH, 13 (54.2%) patients presented with ulcer-like projection and 11 (45.8%) with intimal tear (aortic dissection) in the descending aorta. Successful TEVAR was achieved in all patients. There was no 30-day mortality. During a mean follow-up of 37.5 months, 1 patient (4.2%) developed permanent paralysis, 1 patient (4.2%) underwent reintervention due to the expansion of the aorta distal to the stent resulting from the enlargement of distal intimal tear at the 2 month follow up, and no other adverse events were observed. The latest computed tomographic angiography images showed that the maximum diameter of the ascending aorta and descending aorta significantly decreased after TEVAR (both p<0.001), and the IMH/false lumen in the ascending aorta and the descending thoracic aorta were completely absorbed. Conclusion: Thoracic endovascular aortic repair for selected patients with retrograde type A intramural hematoma that presented with intimal disruption in the descending aorta is feasible and efficient, but close surveillance is needed to manage aortic-related adverse events.

7 November 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
JTJuan Tao
Juan Tao
Hao LiaoHao Liao
Hao Liao
YLYuan Liu
Yuan Liu
QPQingsong Peng
Qingsong Peng
WZWenying Zhu
Wenying Zhu
FYFan Yang
Fan Yang
Objectives: To compare the application value of digital breast tomosynthesis (DBT) and full-field digital mammography (FFDM) in breast galactography. Materials and Methods: A total of 128 patients with pathological nipple discharge (PND) were selected to undergo galactography. DBT and FFDM were performed for each patient after injecting the contrast agent; the radiation dose of DBT and FFDM was calculated, and the image quality was evaluated in consensus by two senior breast radiologists. Histopathologic data were found in 49 of the 128 patients. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for both FFDM- and DBT-galactography were calculated using histopathologic results as a reference standard. Data were presented as percentages along with their 95% confidence intervals (CI). Results: The average age of the 128 patients was 46.53 years. The average glandular dose (AGD) of DBT-galactography was slightly higher than that of FFDM-galactography (p < 0.001). DBT-galactography was 30.7% higher than FFDM-galactography in CC view, while DBT-galactography increased by 21.7% compared with FFDM-galactography in ML view. Regarding catheter anatomic distortion, structure detail, and overall image quality groups, DBT scores were higher than FFDM scores, and the differences were significant for all measures (p < 0.05). In 49 patients with pathological nipple discharge, we found that the DBT-galactography had higher sensitivity, specificity, PPV, and NPV (93.3%, 75%, 97.7%, and 50%, respectively) than FFDM-galactography (91.1%, 50%, 95.3%, and 33.3%, respectively). Conclusions: Compared to FFDM-galactography, within the acceptable radiation dose range, DBT-galactography increases the sensitivity and specificity of lesion detection by improving the image quality, providing more confidence for the diagnosis of clinical ductal lesions.