Shao-Ming/Chuang M.S.

Mr. Shao-Ming/Chuang M.S.

National Yang Ming Chiao Tung University

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HWHung-Wen Wei
Hung-Wen Wei
SMShao-Ming/Chuang M.S.
Shao-Ming/Chuang M.S.
CCChen-Sheng Chen
Chen-Sheng Chen
Minimally invasive decompression is generally employed for treating lumbar spinal stenosis; however, it results in weakened spinal stability. To augment spinal stability, a new interspinous process device (NIPD) was developed in this study. The biomechanical features of the NIPD were evaluated in this study. Three finite-element (FE) models of the entire lumbar spine were implemented to perform biomechanical analysis: the intact, defect (DEF), and NIPD models. The DEF model was considered for lumbar spines with bilateral laminotomies and partial discectomy at L3–L4. Range of motion (ROM), disc stress, and facet joint contact force were evaluated in flexion, extension, torsion, and lateral bending in the three FE models. The results indicated that ROM in the extension increased by 23% in the DEF model but decreased by 23% in the NIPD model. In the NIPD model, the cephalic adjacent disc stress in flexion and extension was within 5%, and negligible changes were noted in the facet joint contact force for torsion and lateral bending. Thus, the NIPD offers superior spinal stability and causes only a minor change in cephalic adjacent disc stress in flexion and extension during the bilateral laminotomy and partial discectomy of the lumbar spine. However, the NIPD has a minor influence on the ROM and facet joint force for lateral bending and torsion.

19 November 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JHJui-Yang Hsieh
Jui-Yang Hsieh
CCChen-Sheng Chen
Chen-Sheng Chen
SMShao-Ming/Chuang M.S.
Shao-Ming/Chuang M.S.
JWJyh-Horng Wang
Jyh-Horng Wang
PCPo-Quang Chen
Po-Quang Chen
PHPhD. Huang
PhD. Huang
The spinal hybrid elastic (SHE) rod is a semi-rigid pedicle screw-based rod for spinal dynamic stabilization. This study investigated the biomechanical effects of different ratios of SHE rod using finite element analysis (FEA). A three-dimensional nonlinear FEA of an intact lumbar spine model (INT) was constructed. The SHE rod was composed of an inner nitinol stick (NS) and an outer polycarbonate urethane shell (PS). Four groups implanted at L3–L4 had the same outer diameter (5.5 mm) but different NS diameter/PS thickness ratios: Nt45, Nt35, Nt25, and Nt15. The resultant intervertebral range of motion (ROM), disc stress, facet joint contact force, screw stress, NS stress, and PCU stress were analyzed. The results indicated that ROM, disc stress, and facet force decreased moderately in the implanted L3–L4 levels and increased slightly in the adjacent L2–L3 levels. The NS stress and NS diameter trended towards inverse proportionality. Changing the ratio did not markedly influence screw or PS stress. The SHE rod system with elastic NS and insulated PS has a 5.5 mm diameter for universal pedicle screws. The SHE rod system provides sufficient spinal support and increases gentle adjacent segment stress. Considering the durability, the optimal NS diameter/PS thickness ratio of the SHE rod system is 3.5/2.0 mm.