Background The aim of this study was to assess the technical success and procedural safety of the new Silk Vista device (SV) by evaluating the intraprocedural and periprocedural complication rate after its use in several institutions worldwide. Methods The study involved a retrospective review of multicenter data regarding a consecutive series of patients with intracranial aneurysms, treated with the SV between September 2020 and January 2021. Clinical, intra/periprocedural and angiographic data, including approach, materials used, aneurysm size and location, device/s, technical details and initial angiographic aneurysm occlusion, were analyzed. Results 60 aneurysms were treated with SV in 57 procedures. 66 devices were used, 3 removed and 63 implanted. The devices opened instantaneously in 60 out of 66 (91%) cases and complete wall apposition was achieved in 58 out of 63 (92%) devices implanted. In 4 out of 66 (6%) devices a partial opening of the distal end occurred, and in 5 (8%) devices incomplete apposition was reported. There were 3 (5%) intraprocedural thromboembolic events managed successfully with no permanent neurological morbidity, and 4 (7%) postprocedural events. There was no mortality in this study. The initial occlusion rates in the 60 aneurysms were as follows: O’Kelly–Marotta (OKM) A in 34 (57%) cases, OKM B in 15 (25%) cases, OKM C in 6 (10%) cases, and OKM D in 5 (8%) cases. Conclusions Our study demonstrated that the use of the new flow diverter Silk Vista for the treatment of intracranial aneurysms is feasible and technically safe.
Herein, we report the case of a 32-year-old man who experienced spontaneous migration of a bullet within the brain following a gunshot injury. Emergent computed tomography revealed the bullet located in the posterosuperior side of mesencephalon. During follow-up after 10 days, the neurological status of the patient had worsened. Computed tomography revealed that the bullet had migrated posteriorly and lodged in the occipital lobe. Although a few studies have reported on the spontaneous migration of a bullet within the brain, the present case is unique as the patient examination changed with migration. We recommend serial imaging and surgery in cases of bullet migration in the brain.
Background: The aim of this study was to investigate the safety and efficiency of the modified balloon assisted coiling (mBAC) technique in endovascular treatment (EVT) of ruptured wide-necked aneurysms (WNAs) to avoid stent placement in the acute phase of subarachnoid hemorrhage (SAH). Methods: The local neurointerventional radiology database was retrospectively reviewed to identify patients who underwent EVT due to ruptured WNAs by the authors. According to the EVT technique performed, the study sample was divided into 3 groups: conventional BAC, stent assisted coiling (SAC), and mBAC. The patient demographics, aneurysm features, technical and clinical complications, aneurysm occlusion grades, morbidity, and mortality rates were comparatively analyzed. Results: This study involved a total of 113 patients who had ruptured WNAs. The mBAC technique was performed on 26 aneurysms (23 saccular and 3 fusiform) in 26 patients to avoid acute phase stenting. The mean continuous balloon inflation time was 7.1 ± 2.12 min. The initial and follow-up angiographic and clinical outcomes were better in the mBAC group than in the SAC group (p < 0.05). Conclusions: The mBAC technique offers a prolonged, continuous balloon inflation time during the whole coiling process in the treatment of ruptured WNAs. The mBAC technique has the potential to obviate the need for SAC in patients who are candidates for stenting during the acute phase of SAH, and it might be considered a safe and effective endovascular approach with low complication rates and good angiographic and clinical outcomes.
15 August 2021 in Turkish Journal of Gastroenterology
Background: To evaluate the frequency of pathological findings determined on magnetic resonance (MR) enterography (MRE) in patients with Crohn’s Disease. Methods: A retrospective analysis of the MRE images was made in 34 female and 41 male patients (mean age 41 years) with Crohn’s disease. The prevalence of bowel wall (mural thickening, mural edema, mural fat deposits, mucosal enhancement, ulceration, cobblestone appearance, pseudopolyps) and mesenteric fatty tissue alterations (fatty tissue proliferation, mesenteric hypervascularity, enlarged lymph nodes, peri-enteric inflammation, reactive fluid), complications due to penetrating (fistula, sinus tract, abscess) and stenosing processes (fibrotic and inflammatory stenosis, obstruction, dilatation), and involvement of the colon were determined. Results: The most frequently observed changes in the bowel wall and mesenteric fatty tissue were mural thickening (98.7%) and enlargement of mesenteric lymph nodes (76%), respectively. Stenosis was the most common complication (76%). The most frequently seen pathology of the colon was ileocecal valve thickening and enhancement (74.7%). Conclusion: MR enterography is a useful imaging modality for the evaluation of changes in both the mesenteric fatty tissue and the bowel wall. As there is no use of ionizing radiation, MR enterography should be the preferred imaging modality during follow-up of patients with Crohn’s disease.