Mario Martínez-Galdámez

Dr. Mario Martínez-Galdámez

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2020 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Open access
PDF file
SDSudeepta Dandapat
Sudeepta Dandapat
AMAlan Mendez-Ruiz
Alan Mendez-Ruiz
MMMario Martínez-Galdámez
Mario Martínez-Galdámez
JMJuan Macho
Juan Macho
SDShahram Derakhshani
Shahram Derakhshani
SGSantiago Ortega Gutierrez
Santiago Ortega Gutierrez
Endovascular treatment of intracranial aneurysms (IAs) has evolved considerably over the past decades. The technological advances have been driven by the experience that coils fail to completely exclude all IAs from the blood circulation, the need to treat the diseased parent vessel segment leading to the aneurysm formation, and expansion of endovascular therapy to treat more complex IAs. Stents were initially developed to support the placement of coils inside wide neck aneurysms. However, early work on stent-like tubular braided structure led to a more sophisticated construct that then later was coined as a flow diverter (FD) and found its way into clinical application. Although FDs were initially used to treat wide-neck large and giant internal carotid artery aneurysms only amenable to surgical trap with or without a bypass or endovascular vessel sacrifice, its use in other types of IAs and cerebrovascular pathology promptly followed. Lately, we have witnessed an explosion in the application of FDs and subsequently their modifications leading to their ubiquitous use in endovascular therapy. In this review we aim to compile the available FD technology, evaluate the devices’ peculiarities from the authors’ perspective, and analyze the current literature to support initial and expanded indications, recognizing that this may be outdated soon.

27 September 2018 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Open access
PDF file
MMMario Martínez-Galdámez
Mario Martínez-Galdámez
SLSaleh M Lamin
Saleh M Lamin
KLKonstantinos G Lagios
Konstantinos G Lagios
TLThomas Liebig
Thomas Liebig
ECElisa F Ciceri
Elisa F Ciceri
EBEdoardo P Boccardi
Edoardo P Boccardi
Purpose The Pipeline Embolization Device (PED) is a routine first-line treatment option for intracranial aneurysms (IAs). The Pipeline Flex Embolization Device with Shield Technology (Pipeline Shield) is an updated version of the PED which has been modified to include a surface phosphorylcholine biocompatible polymer. Its early technical success and safety have been reported previously. Here, we assessed the long-term safety and efficacy of the Pipeline Shield for the treatment of IAs. Materials and methods The Pipeline Flex Embolization Device with Shield Technology (PFLEX) study was a prospective, single-arm, multicenter study for the treatment of unruptured IAs using the Pipeline Shield. The primary endpoint was a major stroke in the territory supplied by the treated artery or neurologic death at 1-year post-procedure. Angiographic outcomes were also assessed by an independent radiology laboratory at 6 months and 1 year. Results Fifty patients (mean age, 53 years; 82% female) with 50 unruptured IAs were treated. Mean aneurysm diameter was 8.82±6.15 mm. Of the target aneurysms, 38/50 (76%) were small (<10 mm), 11/50 (22%) were large (≥10 and<25 mm), and 1/50 (2%) was giant (≥25 mm). Forty-seven (94%) were located in the internal carotid artery and three (6%) in the vertebral artery. At 1-year post-procedure, no major strokes or neurologic deaths were reported, and complete occlusion was achieved in 27/33 (81.8%). There were no instances of aneurysm recurrence or retreatment. Conclusions Our 1-year follow-up concerning angiographic and safety outcomes corroborate previous evidence that the Pipeline Shield is a safe and effective treatment for IAs. Trial registration number NCT02390037

20 February 2017 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Open access
PDF file
MMMario Martínez-Galdámez
Mario Martínez-Galdámez
SLSaleh M Lamin
Saleh M Lamin
KLKonstantinos G Lagios
Konstantinos G Lagios
TLThomas Liebig
Thomas Liebig
ECElisa Francesca Maria Ciceri
Elisa Francesca Maria Ciceri
EBEdoardo P Boccardi
Edoardo P Boccardi
Background and purpose The Pipeline Embolization Device (PED) has become a routine first-line option for treatment of intracranial aneurysms (IAs). We assessed the early safety and technical success of a new version of PED, Pipeline Flex Embolization Device with Shield Technology (Pipeline Shield), which has the same design and configuration but has been modified to include a surface synthetic biocompatible polymer. Materials and methods The Pipeline Flex Embolization Device with Shield Technology (PFLEX) study is a prospective, single-arm, multicenter study for the treatment of unruptured IAs using Pipeline Shield. The primary study endpoints included the occurrence of major stroke in the territory supplied by the treated artery or neurologic death at 1 year post-procedure. Secondary endpoints included the rate of Pipeline Shield-related or procedure-related serious or non-serious adverse events. Analyses were conducted to evaluate early safety findings in the 30-day post-procedure period as well as technical procedural success outcomes. Results Fifty patients with 50 unruptured target IAs were enrolled. Mean aneurysm diameter was 8.82±6.15 mm. Thirty-eight aneurysms (76%) were small (<10 mm). Device deployment was technically successful with 98% of devices. Complete wall apposition was achieved immediately post-procedure in 48 cases (96%). No major strokes or neurologic deaths were reported in the 30-day post-procedure period. Conclusions The results of this first experience with the new Pipeline Flex corroborate the early safety of the device. Mid-term and long-term follow-up examinations will provide data on safety outcomes at the 6-month and 1-year follow-up periods. Clinical trial registration NCT02390037.

1 August 2022 in Stroke
Verified
Journal Article
Closed access
PDF file
LMLukas Meyer
Lukas Meyer
PSPaul Stracke
Paul Stracke
MWMarta Wallocha
Marta Wallocha
GBGabriel Broocks
Gabriel Broocks
PSPeter Sporns
Peter Sporns
FGfrom the TOPMOST Study Group
from the TOPMOST Study Group
Background: The optimal endovascular strategy for reperfusing distal medium-vessel occlusions (DMVO) remains unknown. This study evaluates angiographic and clinical outcomes of thrombectomy strategies in DMVO stroke of the posterior circulation. Methods: TOPMOST (Treatment for Primary Medium Vessel Occlusion Stroke) is an international, retrospective, multicenter, observational registry of patients treated for DMVO between January 2014 and June 2020. This study analyzed endovascularly treated isolated primary DMVO of the posterior cerebral artery in the P2 and P3 segment. Technical feasibility was evaluated with the first-pass effect defined as a modified Thrombolysis in Cerebral Infarction Scale score of 3. Rates of early neurological improvement and functional modified Rankin Scale scores at 90 days were compared. Safety was assessed by the occurrence of symptomatic intracranial hemorrhage and intervention-related serious adverse events. Results: A total of 141 patients met the inclusion criteria and were treated endovascularly for primary isolated DMVO in the P2 (84.4%, 119) or P3 segment (15.6%, 22) of the posterior cerebral artery. The median age was 75 (IQR, 62–81), and 45.4% (64) were female. The initial reperfusion strategy was aspiration only in 29% (41) and stent retriever in 71% (100), both achieving similar first-pass effect rates of 53.7% (22) and 44% (44; P =0.297), respectively. There were no significant differences in early neurological improvement (aspiration: 64.7% versus stent retriever: 52.2%; P =0.933) and modified Rankin Scale rates (modified Rankin Scale score 0–1, aspiration: 60.5% versus stent retriever 68.6%; P =0.4). In multivariable logistic regression analysis, the time from groin puncture to recanalization was associated with the first-pass effect (adjusted odds ratio, 0.97 [95% CI, 0.95–0.99]; P <0.001) that in turn was associated with early neurological improvement (aOR, 3.27 [95% CI, 1.16–9.21]; P <0.025). Symptomatic intracranial hemorrhage occurred in 2.8% (4) of all cases. Conclusions: Both first-pass aspiration and stent retriever thrombectomy for primary isolated posterior circulation DMVO seem to be safe and technically feasible leading to similar favorable rates of angiographic and clinical outcome.

4 October 2023 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Open access
PDF file
VPVitor Mendes Pereira
Vitor Mendes Pereira
HRHal Rice
Hal Rice
LVLaetitia De Villiers
Laetitia De Villiers
NSNader Sourour
Nader Sourour
FCFrédéric Clarencon
Frédéric Clarencon
MPMichel Piotin
Michel Piotin
Background Robotic-assisted neurointervention was recently introduced, with implications that it could be used to treat neurovascular diseases. Objective To evaluate the effectiveness and safety of the robotic-assisted platform CorPath GRX for treating cerebral aneurysms. Methods This prospective, international, multicenter study enrolled patients with brain aneurysms that required endovascular coiling and/or stent-assisted coiling. The primary effectiveness endpoint was defined as successful completion of the robotic-assisted endovascular procedure without any unplanned conversion to manual treatment with guidewire or microcatheter navigation, embolization coil(s) or intracranial stent(s) deployment, or an inability to navigate vessel anatomy. The primary safety endpoint included intraprocedural and periprocedural events. Results The study enrolled 117 patients (74.4% female) with mean age of 56.6 years from 10 international sites,. Headache was the most common presenting symptom in 40/117 (34.2%) subjects. Internal carotid artery was the most common location (34/122, 27.9%), and the mean aneurysm height and neck width were 5.7±2.6 mm and 3.5±1.4 mm, respectively. The overall procedure time was 117.3±47.3 min with 59.4±32.6 min robotic procedure time. Primary effectiveness was achieved in 110/117 (94%) subjects with seven subjects requiring conversion to manual for procedure completion. Only four primary safety events were recorded with two intraprocedural aneurysm ruptures and two strokes. A Raymond-Roy Classification Scale score of 1 was achieved in 71/110 (64.5%) subjects, and all subjects were discharged with a modified Rankin Scale score of ≤2. Conclusions This first-of-its-kind robotic-assisted neurovascular trial demonstrates the effectiveness and safety of the CorPath GRX System for endovascular embolization of cerebral aneurysm procedures. Trial registration number NCT04236856

16 February 2022 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
DVDominik F. Vollherbst
Dominik F. Vollherbst
HCH Saruhan Cekirge
H Saruhan Cekirge
ISIsil Saatci
Isil Saatci
FBFeyyaz Baltacioglu
Feyyaz Baltacioglu
BOBaran Onal
Baran Onal
MMMarkus A. Möhlenbruch
Markus A. Möhlenbruch
Background Flow diversion is an innovative and increasingly used technique for the treatment of intracranial aneurysms. New flow diverters (FDs) are being introduced to improve the safety and efficacy of this treatment. The aim of this study was to assess the safety, feasibility, and efficacy of the new Pipeline Vantage (PV) FD. Methods Patients with intracranial aneurysms treated with the PV at 10 international neurovascular centers were retrospectively analyzed. Patient and aneurysm characteristics, procedural parameters, complications, and the grade of occlusion were assessed. Results 60 patients with 70 aneurysms (5.0% with acute hemorrhage, 90.0% located in the anterior circulation) were included. 82 PVs were implanted in 61 treatment sessions. The PV could be successfully implanted in all treatments. Additional coiling was performed in 18.6%, and in-stent balloon angioplasty (to enhance the vessel wall apposition) in 24.6%. Periprocedural technical complications occurred in 24.6% of the treatments, were predominantly FD deployment problems, and were all asymptomatic. The overall symptomatic complication rate was 8.2% and the neurological symptomatic complication rate was 3.3%. Only one symptomatic complication was device-related (perforator artery infarctions leading to stroke). After a mean follow-up of 7.1 months, the rate of complete aneurysm occlusion was 77.9%. One patient (1.7%) died due to aneurysmal subarachnoid hemorrhage which occurred before treatment, unrelated to the procedure. Conclusions The new PV FD is safe and feasible for the treatment of intracranial aneurysms. The short-term occlusion rates are promising but need further assessment in prospective long-term follow-up studies.