The fault characteristics of the wind power system, which are reflected in the weak feed features, variation of system impedance, frequency deviation, and non-sinusoidal waveform, will cause the inadaptation of traditional phase selectors to a wind power integration system. In this paper, a new phase selection principle based on the waveform correlation of transient voltage is proposed, which is valid for relay protection of intermittent solar or wind power plants. First, the characteristics of transient voltage of various fault types are deduced according to their boundary conditions. And on this basis, the correlations between the fault transient voltages of every two phases can be acquired. With the differentiated waveform correlations of different fault types, the fault phase selection criterion based on correlation coefficient is formed accordingly. Because it depends on the waveform characteristics of fault transient voltages, the new phase selector is not influenced by the wind power system's fault characteristics and it can select the correct fault phase quickly with high sensitivity. The proposed novel phase selection criterion is verified by the PSCAD-based simulation results and field fault recording data of the wind power integration system.
1 January 2015 in Canadian Journal of Electrical and Computer Engineering
Wind power is developing rapidly as a means of handling the world's energy shortage and associated environmental problems. The Gansu provincial wind energy resources have around 237-GW wind power potential in China. In this paper, a study on key technologies of Hexi 750-kV power transmission line protections has been carried out. The project includes some characteristics, such as large-scale wind power, long-distance EHV lines, and so on. We used 49.5-MW doubly fed induction generator (DFIG) wind turbines in this project and different situations when a fault occurs in the presence of DFIG are studied and investigated. By the aid of stator-flux-oriented vector strategy, the system is modeled in PSCAD/EMTDC software on the basis of the real information from the wind farm site. The fault analysis is studied while the fault location is changed and the crowbar protection is ON/OFF. The data and information have been obtained by field experience of the wind farm in Gansu province. Also, the matrix pencil algorithm has been applied as a novel method in this project. This analysis can ease the protection issues and push the schedule to the next steps. With these results, we are able to adapt our system with smart grids and provide some novel methods to stabilize and control the wind farm.
After a large number of electric vehicles (EVs) are connected to the integrated energy system, disorderly charging and discharging of EVs will have a negative impact on the safe and stable operation of the system. In addition, EVs’ uncertain travel plans and the stochastic fluctuation of renewable energy output and load power will bring risks and challenges. In view of the above problems, this paper establishes a hierarchical stochastic optimal scheduling model of an electric thermal hydrogen integrated energy system (ETH-IES) considering the EVs vehicle-to-grid (V2G) mechanism. The EVs charging and discharging management layer aims to minimize the variance of the load curve and minimize the dissatisfaction of EV owners participating in V2G. The multi-objective sand cat swarm optimization (MSCSO) algorithm is used to solve the proposed model. On this basis, the daily stochastic economic scheduling of ETH-IES is carried out with the goal of minimizing the operation cost. The simulation results show that the proposed strategy can better achieve a win-win situation between EV owners and microgrid operators, and the operation cost of the proposed strategy is reduced by 16.55% compared with that under the disorderly charging and discharging strategy, which verifies the effectiveness of the proposed model and algorithm.
1
7 November 2024 in IEEE Transactions on Power Delivery
Low frequency transmission system (LFTS) has become a competitive method for long-distance offshore wind power transmission. However, traditional protections based on the fundamental frequency phasor may have poor performance since both ends of submarine cables connect with power electronic devices. First, the adaptability of traditional protections is analyzed. It is found that fault characteristics are weakened by typical control strategies. To enhance the characteristic difference between internal and external faults, an impedance construction method for grid-side converter (GSC) and modular multilevel matrix converter (M3C) is proposed. Then this paper proposes a directional pilot protection. For asymmetrical faults, the angle of negative-sequence impedance of GSC and M3C is determined by references of current loop controller. For symmetrical faults, adjusting coefficients of current loop reference in GSC helps the protection perform well under high-resistance faults. Building the sequence networks under different fault types, a phase selection method based on voltage magnitude is proposed. Finally, simulation tests are conducted in PSCAD/EMTDC, and the results demonstrate that the proposed impedance construction method can provide effective support for fault identification and the proposed protection performs well under various fault scenarios.
With the integration of large-scale renewable energy into the power grids, cross-regional power trade can play a major role in promoting renewable energy consumption, as it can effectively achieve the optimal allocation of interconnected power grid resources and ensure the safe and economic operation of the power grid. An optimization model on a mid/long-term scale is established, considering the relationship between the renewable energy absorption interval and the regulation of resources in the system. The model is based on the load block curve and the renewable energy power model, considering the maintenance constraints of conventional units, the operation constraints of conventional units and renewable energy units, cross-regional power trade constraints and system operation constraints. By analyzing the results of the adapted IEEE RELIABILITY TEST SYSTEM (IEEE-RTS), the validity of the model and method proposed in this paper is proven. The results show that the coordinated optimization of conventional energy and renewable energy in the system can be achieved, and the complementarity of power supply and load can be promoted.
A combined heating and power (CHP) microgrid has high flexibility and economy, but the output of renewable energy is uncertain. Meanwhile, excessive flexible load adjustment in the demand response process will increase user dissatisfaction. In order to solve the above problems, this paper quantifies uncertainty with the conditional value-at-risk (CVaR) of relative disturbance. Additionally, a multi-objective optimal scheduling model that takes into account both the operating economy and the demand-side power consumption satisfaction is established. In order to solve the multi-objective mixed-integer nonlinear programming problem well, we propose an improved sparrow search algorithm (ISSA), which solves the problem that the sparrow search algorithm (SSA) is prone to low accuracy, insufficient in population diversity and easy to be trapped in local optimum. Combined with the non-dominated solution ranking method, ISSA has the ability of multi-objective optimization. Finally, simulation on a typical CHP microgrid is performed. The optimization results under different confidence levels and risk preference coefficients are compared and analyzed. When the risk preference coefficient is 0.1, 2 and 5, the minimum rotating reserve capacity is 75.17 kW, 82.83 kW, and 105.70 kW in the electric part and 40.08 kW, 59.89 kW, and 61.94 kW in the thermal part. The effectiveness of the proposed CVaR of relative disturbance is verified.