Xiaoping Gao

Xiaoping Gao

Auto-generated profile, based on publicly available information

Xiaoping Gao

School of Electrical Engineering, Xian Jiaotong University, Xian, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2024 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
XGXiaoping Gao
Xiaoping Gao
SGSong Guobing
Song Guobing
CZChenhao Zhang
Chenhao Zhang
Xiaoning KangXiaoning Kang
Xiaoning Kang
JYJifei Yan
Jifei Yan
Low frequency transmission system (LFTS) has become a competitive method for long-distance offshore wind power transmission. However, traditional protections based on the fundamental frequency phasor may have poor performance since both ends of submarine cables connect with power electronic devices. First, the adaptability of traditional protections is analyzed. It is found that fault characteristics are weakened by typical control strategies. To enhance the characteristic difference between internal and external faults, an impedance construction method for grid-side converter (GSC) and modular multilevel matrix converter (M3C) is proposed. Then this paper proposes a directional pilot protection. For asymmetrical faults, the angle of negative-sequence impedance of GSC and M3C is determined by references of current loop controller. For symmetrical faults, adjusting coefficients of current loop reference in GSC helps the protection perform well under high-resistance faults. Building the sequence networks under different fault types, a phase selection method based on voltage magnitude is proposed. Finally, simulation tests are conducted in PSCAD/EMTDC, and the results demonstrate that the proposed impedance construction method can provide effective support for fault identification and the proposed protection performs well under various fault scenarios.

25 June 2024 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
JYJifei Yan
Jifei Yan
SGSong Guobing
Song Guobing
ZCZhongxue Chang
Zhongxue Chang
XGXiaoping Gao
Xiaoping Gao
CZChenhao Zhang
Chenhao Zhang
Fault location plays a pivotal role in expediting the restoration of systems after faults. However, the necessity for rapid fault isolation in multi-terminal direct current (MTDC) systems dictates that only a few milliseconds of data are available for fault location. Therefore, accurately determining the fault location using an extreme short data window presents a challenge. To address this challenge, a frequency domain fault location method that utilizes data from both ends of lines is proposed. This method accurately considers frequency-dependent and distributed characteristics of line parameters and relies on data collected within 3 ms following a fault occurrence. Initially, the fault location equation is derived. Then, the numerical Laplace transform (NLT) method is introduced to solve this equation, from which the explicit expression for fault distance is obtained. Lastly, the comprehensive fault location scheme is outlined. Numerical simulations demonstrate that this method can accurately locate faults and exhibit good robustness against fault impedance. Additionally, the method features a reduced computational burden, higher accuracy, and stronger noise immunity compared to existing methods.

12 June 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SGSong Guobing
Song Guobing
JYJifei Yan
Jifei Yan
ZCZhongxue Chang
Zhongxue Chang
CZChenhao Zhang
Chenhao Zhang
XGXiaoping Gao
Xiaoping Gao
Accurate fault location with a short data window is crucial and challenging for cable faults in the modular multilevel converter high voltage direct current (MMC-HVDC) system. Aiming at this issue, this paper proposes a frequency-domain fault location method, which accurately and comprehensively addresses the frequency dependency and unbalance of the parameter matrices without any approximation while considering the distributed parameters. Firstly, the frequency-domain decoupling is analyzed for DC cables with the metallic sheath and armor grounded at two terminals. Secondly, a method is proposed to calculate the voltage distribution along the cable using voltages and currents at one side of the cable based on the numerical Laplace transform (NLT). Subsequently, the cable parameter calculation method suitable for the NLT is presented, and a multi-round iterative algorithm for voltage distribution calculation is proposed. Ultimately, the complete fault location scheme is presented. Extensive simulations validate that the proposed method can achieve fault location with minor errors using a 20 kHz sampling rate and a 4 ms data window. Besides, high accuracy is maintained even under the influence of large fault impedance and noise. Compared to existing methods, the approach exhibits lower fault location error while requiring less computational complexity.

1 July 2026 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
JYJifei Yan
Jifei Yan
PLPengfei Liu
Pengfei Liu
ZCZhongxue Chang
Zhongxue Chang
SGSong Guobing
Song Guobing
XGXiaoping Gao
Xiaoping Gao

17 September 2026 in Electric Power Systems Research
Verified
Journal Article
Closed access
JYJifei Yan
Jifei Yan
PLPengfei Liu
Pengfei Liu
ZCZhongxue Chang
Zhongxue Chang
GSGuobing Song
Guobing Song
XGXiaoping Gao
Xiaoping Gao