With the continuous expansion of the scale of power generated by grid-connected renewable energy, the form and operation characteristics of power grids have undergone significant changes, and the power electronic characteristics of power systems are prominent, resulting in the frequent occurrence of wide-band oscillation problems when renewable energy power generation equipment is connected to a power grid. Oscillation has the characteristics of nonlinearity and has an oscillation frequency ranging from a few hertz to several thousand hertz or more, which seriously threatens the stable operation of power grids. This paper summarizes the wide-band oscillation events that occur worldwide under the background of renewable energy access to power grids, classifies the wide-band oscillation events according to the distribution of oscillation frequency bands, and sorts out the characteristics of various oscillations. From the perspectives of the source side and network side, the existing oscillation suppression measures are classified and prospected.
With the increase in capacitor voltage transformer (CVT) operation life, CVT impedance changes, and the short-time switching of overhead lines, it is very easy to cause a transient oscillation accident in which a CVT participates, reduce the insulation level of a CVT, and even induce regional power grid oscillation and easily cause capacitor breakdown, after long-term operation with defects. In this paper, the whole power network, including the generator, power grid, and consumer, is modeled, and the theoretical model of the CVT ferro-resonance connected grid is built. The frequency spectrum analysis, and the measurements of resonance bus voltage and line voltage, were carried out to find the design method of a fast saturation damper (FSD) and its voltage–current characteristics that affect the vibration, based on theory and practice; this paper puts forward effective measures to reduce the resonance effect of a CVT in operation, and avoid the oscillation of the line and even the regional power grid system.
With the growth of energy demand and the aggravation of environmental problems, solar photovoltaic (PV) power generation has become a research hotspot. As the key interface between new energy generation and power grids, a PV grid-connected inverter ensures that the power generated by new energy can be injected into the power grid in a stable and safe way, and its power grid adaptability has also received more and more close attention in the field of new energy research. This research focuses on the discussion of PV grid-connected inverters under the complex distribution network environment, introduces in detail the domestic and international standards and requirements on grid-connected inverter grid adaptability, and then analyzes in depth the impacts of the access point voltage changes, access point frequency changes, and access point harmonic changes on the inverters. In order to enhance the adaptability of grid-connected inverters under these abnormal conditions, this research systematically summarizes and concludes a series of inverter adaptive control strategies, which provide literature guidance to effectively reduce the probability of power system faults and improve the reliability of the power system. Finally, the future development direction of PV inverter technology is outlooked, pointing out that, with the increase in the proportion of PV power generation in the power system, PV inverters need to evolve gradually from adapting to the grid to supporting the grid and promote the transformation of PV power generation from the auxiliary power source to the main power source through the integration of PV and energy storage.
31 March 2025 in IEEE Transactions on Industrial Electronics
The synchronous reluctance motor (SynRM) possesses a simple structure and low cost. However, its application is hindered by high-torque ripple. Traditional asymmetric designs can effectively suppress torque ripple. However, it often exhibits poor performance during reverse rotation and lacks theoretical guidance. In this article, an analytical model is developed to establish the relationship between torque and flux barrier end angles. A novel technique is then proposed to mitigate the torque ripple of the SynRM by introducing mirror asymmetric rotor laminations. These laminations feature asymmetrically designed flux barriers in one pole and periodically symmetric ones in the adjacent pole, arranged in a mirrored stacking configuration. The proposed technique is implemented in practical machines, and the effectiveness of the proposed method is validated through experimental tests.
Temperature superconducting (HTS) synchronous condenser is a reactive power compensation device with the advantages of low loss, high efficiency and wide reactive power range. Therefore, it has a very good application prospect in power grid. To solve the problems of low power factor and low conduction angle of constant excitation function for a long time due to single power supply excitation system, this paper proposes a high-low voltage switching excitation system, which separates the forced excitation and constant excitation modes of the excitation system into two power supplies. Based on the introduction of principle of excitation system, the design of its parameters and simulation analysis are completed, and a set of 400kW device is designed. On this basis, a series of corresponding superconducting experiment are carried out. The experimental results verify the principle of the power supply topology, and also show the feasibility and reliability of the proposed excitation system.
Icing on transmission lines poses a serious threat to the power grid. Existing de-icing solutions have limitations in short-distance distribution networks with multiple branches. We propose a method that utilizes a flexible grounding device to adjust the zero-sequence reactive current in the distribution network, enabling de-icing of lines without power interruption. Simulation and experimental results validate the feasibility and effectiveness of the proposed method and control scheme. The method can accurately regulate the de-icing current to achieve de-icing under various conditions, with the actual de-icing current deviating from the set value by less than 0.3%. During de-icing, the line voltage on the load side remains essentially stable, with an error of less than 0.5%, ensuring that the normal supply voltage of the distribution network is not affected, and the entire network load does not require a power outage. The de-icing device interacts only with reactive power in the distribution network, saving capacity for the DC voltage stabilizing power supply and demonstrating good economic efficiency.