Guillem Casas

Dr. Guillem Casas

Hospital Universitari Vall d'Hebron, Barcelona
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
Matteo CameliMatteo Cameli
Matteo Cameli
MMMarcelo Miglioranza
Marcelo Miglioranza
JMJulien Magne
Julien Magne
Giulia Elena MandoliGiulia Elena Mandoli
Giulia Elena Mandoli
GBGiovanni Benfari
Giovanni Benfari
Bogdan PopescuBogdan Popescu
Bogdan Popescu
Two methods are currently available for left atrial (LA) strain measurement by speckle tracking echocardiography, with two different reference timings for starting the analysis: QRS (QRS-LASr) and P wave (P-LASr). The aim of MASCOT HIT study was to define which of the two was more reproducible, more feasible, and less time consuming. In 26 expert centers, LA strain was analyzed by two different echocardiographers (young vs senior) in a blinded fashion. The study population included: healthy subjects, patients with arterial hypertension or aortic stenosis (LA pressure overload, group 2) and patients with mitral regurgitation or heart failure (LA volume–pressure overload, group 3). Difference between the inter-correlation coefficient (ICC) by the two echocardiographers using the two techniques, feasibility and analysis time of both methods were analyzed. A total of 938 subjects were included: 309 controls, 333 patients in group 2, and 296 patients in group 3. The ICC was comparable between QRS-LASr (0.93) and P-LASr (0.90). The young echocardiographers calculated QRS-LASr in 90% of cases, the expert ones in 95%. The feasibility of P-LASr was 85% by young echocardiographers and 88% by senior ones. QRS-LASr young median time was 110 s (interquartile range, IR, 78-149) vs senior 110 s (IR 78-155); for P-LASr, 120 s (IR 80-165) and 120 s (IR 90-161), respectively. LA strain was feasible in the majority of patients with similar reproducibility for both methods. QRS complex guaranteed a slightly higher feasibility and a lower time wasting compared to the use of P wave as the reference.

22 May 2022 in European Journal of Heart Failure
Verified
Journal Article
Open access
JMJesús G. Mirelis
Jesús G. Mirelis
LELuis Escobar‐Lopez
Luis Escobar‐Lopez
JOJuan Pablo Ochoa
Juan Pablo Ochoa
MEMaría Ángeles Espinosa
María Ángeles Espinosa
EAEduardo Villacorta Argüelles
Eduardo Villacorta Argüelles
PGPablo García‐Pavía
Pablo García‐Pavía
Aims: Genotype and left ventricular scar on cardiac magnetic resonance (CMR) are increasingly recognized as risk markers for adverse outcomes in non‐ischaemic dilated cardiomyopathy (DCM). We investigated the combined influence of genotype and late gadolinium enhancement (LGE) in assessing prognosis in a large cohort of patients with DCM. Methods and results: Outcomes of 600 patients with DCM (53.3 ± 14.1 years, 66% male) who underwent clinical CMR and genetic testing were retrospectively analysed. The primary endpoints were end‐stage heart failure (ESHF) and malignant ventricular arrhythmias (MVA). During a median follow‐up of 2.7 years (interquartile range 1.3–4.9), 24 (4.00%) and 48 (8.00%) patients had ESHF and MVA, respectively. In total, 242 (40.3%) patients had pathogenic/likely pathogenic variants (positive genotype) and 151 (25.2%) had LGE. In survival analysis, positive LGE was associated with MVA and ESHF (both, p < 0.001) while positive genotype was associated with ESHF ( p = 0.034) but not with MVA ( p = 0.102). Classification of patients according to genotype (G+/G−) and LGE presence (L+/L−) revealed progressively increasing events across L−/G−, L−/G+, L+/G− and L+/G+ groups and resulted in optimized MVA and ESHF prediction ( p < 0.001 and p = 0.001, respectively). Hazard ratios for MVA and ESHF in patients with either L+ or G+ compared with those with L−/G− were 4.71 (95% confidence interval: 2.11–10.50, p < 0.001) and 7.92 (95% confidence interval: 1.86–33.78, p < 0.001), respectively. Conclusion: Classification of patients with DCM according to genotype and LGE improves MVA and ESHF prediction. Scar assessment with CMR and genotyping should be considered to select patients for primary prevention implantable cardioverter‐defibrillator placement.

28 March 2022 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
ARAroa Ruiz-Muñoz
Aroa Ruiz-Muñoz
AGAndrea Guala
Andrea Guala
LDLydia Dux-Santoy
Lydia Dux-Santoy
GTGisela Teixido-Tura
Gisela Teixido-Tura
MSMaria Luz Servato
Maria Luz Servato
JRJose Rodríguez-Palomares
Jose Rodríguez-Palomares
Patency of the false lumen in chronic aortic dissection (AD) is associated with aortic dilation and long-term aortic events. However, predictors of adverse outcomes in this population are limited. The aim of this study was to evaluate the relationship between aortic growth rate and false lumen flow dynamics and biomechanics in patients with chronic, patent AD. Patients with a chronic AD with patent false lumen in the descending aorta and no genetic connective tissue disorder underwent an imaging follow-up including a contrast-enhanced 4D flow cardiovascular magnetic resonance (CMR) protocol and two consecutive computed tomography angiograms (CTA) acquired at least 1 year apart. A comprehensive analysis of anatomical features (including thrombus quantification), and false lumen flow dynamics and biomechanics (pulse wave velocity) was performed. Fifty-four consecutive patients with a chronic, patent false lumen in the descending aorta were included (35 surgically-treated type A AD with residual tear and 19 medically-treated type B AD). Median follow-up was 40 months. The in-plane rotational flow, pulse wave velocity and the percentage of thrombus in the false lumen were positively related to aortic growth rate (p = 0.006, 0.017, and 0.037, respectively), whereas wall shear stress showed a trend for a positive association (p = 0.060). These results were found irrespectively of the type of AD. In patients with chronic AD and patent false lumen of the descending aorta, rotational flow, pulse wave velocity and wall shear stress are positively related to aortic growth rate, and should be implemented in the follow-up algorithm of these patients. Further prospective studies are needed to confirm if the assessment of these parameters helps to identify patients at higher risk of adverse clinical events.

17 January 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AEArturo Evangelista
Arturo Evangelista
LGLaura Galian-Gay
Laura Galian-Gay
AGAndrea Guala
Andrea Guala
ALAngela Lopez-Sainz
Angela Lopez-Sainz
GTGisela Teixido-Tura
Gisela Teixido-Tura
JRJose Rodríguez-Palomares
Jose Rodríguez-Palomares
Multimodality imaging is the basis of the diagnosis, follow-up, and surgical management of bicuspid aortic valve (BAV) patients. Transthoracic echocardiography (TTE) is used in our clinical routine practice as a first line imaging for BAV diagnosis, valvular phenotyping and function, measurement of thoracic aorta, exclusion of other aortic malformations, and for the assessment of complications such are infective endocarditis and aortic. Nevertheless, TTE is less useful if we want to assess accurately other aortic segments such as mid-distal ascending aorta, where computed tomography (CT) and magnetic resonance (CMR) could improve the precision of aorta size measurement by multiplanar reconstructions. A major advantage of CT is its superior spatial resolution, which affords a better definition of valve morphology and calcification, accuracy, and reproducibility of ascending aorta size, and allows for coronary artery assessment. Moreover, CMR offers the opportunity of being able to evaluate aortic functional properties and blood flow patterns. In this setting, new developed sequences such as 4D-flow may provide new parameters to predict events during follow up. The integration of all multimodality information facilitates a comprehensive evaluation of morphologic and dynamic features, stratification of the risk, and therapy guidance of this cohort of patients.

14 December 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MHMichael Henein
Michael Henein
Giulia Elena MandoliGiulia Elena Mandoli
Giulia Elena Mandoli
Maria Concetta PastoreMaria Concetta Pastore
Maria Concetta Pastore
NGNicolò Ghionzoli
Nicolò Ghionzoli
FHFouhad Hasson
Fouhad Hasson
Matteo CameliMatteo Cameli
Matteo Cameli
Background: The COVID-19 pandemic carries a high burden of morbidity and mortality worldwide. We aimed to identify possible predictors of in-hospital major cardiovascular (CV) events in COVID-19. Methods: We retrospectively included patients hospitalized for COVID-19 from 10 centers. Clinical, biochemical, electrocardiographic, and imaging data at admission and medications were collected. Primary endpoint was a composite of in-hospital CV death, acute heart failure (AHF), acute myocarditis, arrhythmias, acute coronary syndromes (ACS), cardiocirculatory arrest, and pulmonary embolism (PE). Results: Of the 748 patients included, 141(19%) reached the set endpoint: 49 (7%) CV death, 15 (2%) acute myocarditis, 32 (4%) sustained-supraventricular or ventricular arrhythmias, 14 (2%) cardiocirculatory arrest, 8 (1%) ACS, 41 (5%) AHF, and 39 (5%) PE. Patients with CV events had higher age, body temperature, creatinine, high-sensitivity troponin, white blood cells, and platelet counts at admission and were more likely to have systemic hypertension, renal failure (creatinine ≥ 1.25 mg/dL), chronic obstructive pulmonary disease, atrial fibrillation, and cardiomyopathy. On univariate and multivariate analysis, troponin and renal failure were associated with the composite endpoint. Kaplan–Meier analysis showed a clear divergence of in-hospital composite event-free survival stratified according to median troponin value and the presence of renal failure (Log rank p < 0.001). Conclusions: Our findings, derived from a multicenter data collection study, suggest the routine use of biomarkers, such as cardiac troponin and serum creatinine, for in-hospital prediction of CV events in patients with COVID-19.

14 November 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MSMaria Luz Servato
Maria Luz Servato
GTGisela Teixido-Tura
Gisela Teixido-Tura
ASAnna Sabate-Rotes
Anna Sabate-Rotes
LGLaura Galian-Gay
Laura Galian-Gay
LGLaura Gutiérrez
Laura Gutiérrez
AEArturo Evangelista
Arturo Evangelista
Ascending aorta diameters have important clinical value in the diagnosis, follow-up, and surgical indication of many aortic diseases. However, there is no uniformity among experts regarding ascending aorta diameter quantification by echocardiography. The aim of this study was to compare maximum aortic root and ascending aorta diameters determined by the diastolic leading edge (DLE) and the systolic inner edge (SIE) conventions in adult and pediatric patients with inherited cardiovascular diseases. Transthoracic echocardiograms were performed in 328 consecutive patients (260 adults and 68 children). Aorta diameters were measured twice at the root and ascending aorta by the DLE convention following the 2015 American Society of Echocardiography (ASE) adult guidelines and the SIE convention following the 2010 ASE pediatric guidelines. Comparison of the diameters measured by the two conventions in the overall population showed a non-significant underestimation of the diameter measured by the SIE convention at root level of 0.28 mm (CI −1.36; 1.93) and at tubular ascending aorta level of 0.17 mm (CI −1.69; 2.03). Intraobserver and interobserver variability were excellent. Maximum aorta diameter measured by the leading edge convention in end-diastole and the inner edge convention in mid-systole had similar values to a mild non-significant underestimation of the inner-to-inner method that permits them to be interchangeable when used in clinical practice.