8 November 2015 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
CBChristian Bäumer
Christian Bäumer
BKBenjamin Koska
Benjamin Koska
JLJamil Lambert
Jamil Lambert
BTBeate Timmermann
Beate Timmermann
TMThierry Mertens
Thierry Mertens
PTPatrick Takoukam Talla
Patrick Takoukam Talla
Acquisition of quasi‐monoenergetic ("pristine") depth‐dose curves is an essential task in the frame of commissioning and quality assurance of a proton therapy treatment head. For pencil beam scanning delivery modes this is often accomplished by measuring the integral ionization in a plane perpendicular to the axis of an unscanned beam. We focus on the evaluation of three integral detectors: two of them are plane‐parallel ionization chambers with an effective radius of 4.1 cm and 6.0 cm, respectively, mounted in a scanning water phantom. The third integral detector is a 6.0 cm radius multilayer ionization chamber. The experimental results are compared with the corresponding measurements under broad field conditions, which are performed with a small radius plane‐parallel chamber and a small radius multilayer ionization chamber. We study how a measured depth‐dose curve of a pristine proton field depends on the detection device, by evaluating the shape of the depth‐dose curve, the relative charge collection efficiency, and intercomparing measured ranges. Our results show that increasing the radius of an integral chamber from 4.1 cm to 6.0 cm increases the collection efficiency by 0%–3.5% depending on beam energy and depth. Ranges can be determined by the large electrode multilayer ionization chamber with a typical uncertainty of 0.4 mm on a routine basis. The large electrode multilayer ionization chamber exhibits a small distortion in the Bragg Peak region. This prohibits its use for acquisition of base data, but is tolerable for quality assurance. The good range accuracy and the peak distortion are characteristics of the multilayer ionization chamber design, as shown by the direct comparison with the small electrode counterpart.PACS number: 87.55.Qr

17 December 2021 in Small
Verified
Journal Article
Open access
PDF file
SZSandra Zwiehoff
Sandra Zwiehoff
JJJacob Johny
Jacob Johny
CBCarina Behrends
Carina Behrends
ALAlina Landmann
Alina Landmann
FMFlorian Mentzel
Florian Mentzel
SBStephan Barcikowski
Stephan Barcikowski
Proton‐based radiotherapy is a modern technique for the treatment of solid tumors with significantly reduced side effects to adjacent tissues. Biocompatible nanoparticles (NPs) with high atomic numbers are known to serve as sensitizers and to enhance treatment efficacy, which is commonly believed to be attributed to the generation of reactive oxygen species (ROS). However, little systematic knowledge is available on how either physical effects due to secondary electron generation or the particle surface chemistry affect ROS production. Thereto, ligand‐free colloidal platinum (Pt) and gold (Au) NPs with well‐controlled particle size distributions and defined total surface area are proton‐irradiated. A fluorescence‐based assay is developed to monitor the formation of ROS using terephthalic acid as a cross‐effect‐free dye. The findings indicate that proton irradiation (PI)‐induced ROS formation sensitized by noble metal NPs is driven by the total available particle surface area rather than particle size or mass. Furthermore, a distinctive material effect with Pt being more active than Au is observed which clearly indicates that the chemical reactivity of the NP surface is a main contributor to ROS generation upon PI. These results pave the way towards an in‐depth understanding of the NP‐induced sensitizing effects upon PI and hence a well‐controlled enhanced therapy.

1 November 2017 in Physica Medica
Verified
Journal Article
Closed access
CBChristian Bäumer
Christian Bäumer
DGD. Geismar
D. Geismar
BKB. Koska
B. Koska
PKP.H. Kramer
P.H. Kramer
JLJ. Lambert
J. Lambert
XVX. Vermeren
X. Vermeren

1 April 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
CBChristian Bäumer
Christian Bäumer
MJM Janson
M Janson
BTB Timmermann
B Timmermann
JWJörg Wulff
Jörg Wulff
To assess if apertures shall be mounted upstream or downstream of a range shifting block if these field-shaping devices are combined with the pencil-beam scanning delivery technique (PBS). The lateral dose fall-off served as a benchmark parameter. Both options realizing PBS-with-apertures were compared to the uniform scanning mode. We also evaluated the difference regarding the out-of-field dose caused by interactions of protons in beam-shaping devices. The potential benefit of the downstream configuration over the upstream configuration was estimated analytically. Guided by this theoretical evaluation a mechanical adapter was developed which transforms the upstream configuration provided by the proton machine vendor to a downstream configuration. Transversal dose profiles were calculated with the Monte-Carlo based dose engine of the commercial treatment planning system RayStation 6. Two-dimensional dose planes were measured with an ionization chamber array and a scintillation detector at different depths and compared to the calculation. Additionally, a clinical example for the irradiation of the orbit was compared for both PBS options and a uniform scanning treatment plan. Assuming the same air gap the lateral dose fall-off at the field edge at a few centimeter depth is 20% smaller for the aperture-downstream configuration than for the upstream one. For both options of PBS-with-apertures the dose fall-off is larger than in uniform scanning delivery mode if the minimum accelerator energy is 100 MeV. The RayStation treatment planning system calculated the width of the lateral dose fall-off with an accuracy of typically 0.1 mm–0.3 mm. Although experiments and calculations indicate a ranking of the three delivery options regarding lateral dose fall-off, there seems to be a limited impact on a multi-field treatment plan.

12 May 2021 in Frontiers in Oncology
Verified
Journal Article
Open access
PDF file
CBChristian Bäumer
Christian Bäumer
SPSandija Plaude
Sandija Plaude
DKDalia Ahmad Khalil
Dalia Ahmad Khalil
DGDirk Geismar
Dirk Geismar
PKPaul-Heinz Kramer
Paul-Heinz Kramer
BTBeate Timmermann
Beate Timmermann
Proton therapy makes use of the favorable depth-dose distribution with its characteristic Bragg peak to spare normal tissue distal of the target volume. A steep dose gradient would be desired in lateral dimensions, too. The widespread spot scanning delivery technique is based, however, on pencil-beams with in-air spot full-widths-at-half-maximum of typically 1 cm or more. This hampers the sparing of organs-at-risk if small-scale structures adjacent to the target volume are concerned. The trimming of spot scanning fields with collimating apertures constitutes a simple measure to increase the transversal dose gradient. The current study describes the clinical implementation of brass apertures in conjunction with the pencil-beam scanning delivery mode at a horizontal, clinical treatment head based on commercial hardware and software components. Furthermore, clinical cases, which comprised craniopharyngiomas, re-irradiations and ocular tumors, were evaluated. The dosimetric benefits of 31 treatment plans using apertures were compared to the corresponding plans without aperture. Furthermore, an overview of the radiation protection aspects is given. Regarding the results, robust optimization considering range and setup uncertainties was combined with apertures. The treatment plan optimizations followed a single-field uniform dose or a restricted multi-field optimization approach. Robustness evaluation was expanded to account for possible deviations of the center of the pencil-beam delivery and the mechanical center of the aperture holder. Supplementary apertures improved the conformity index on average by 15.3%. The volume of the dose gradient surrounding the PTV (evaluated between 80 and 20% dose levels) was decreased on average by 17.6%. The mean dose of the hippocampi could be reduced on average by 2.9 GyRBE. In particular cases the apertures facilitated a sparing of an organ-at-risk, e.g. the eye lens or the brainstem. For six craniopharyngioma cases the inclusion of apertures led to a reduction of the mean dose of 1.5 GyRBE (13%) for the brain and 3.1 GyRBE (16%) for the hippocampi.

1 August 2019 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
CBChristian Bäumer
Christian Bäumer
CFCarolina Fuentes
Carolina Fuentes
MJMartin Janson
Martin Janson
AMAndrija Matic
Andrija Matic
BTBeate Timmermann
Beate Timmermann
JWJörg Wulff
Jörg Wulff
Some clinical indications require small fields with sharp lateral dose gradients, which is technically challenging in proton beam therapy. This holds especially true for low-range fields applied with the spot scanning technique, where large beam profiles entering from the beam-line or the insertion of range shifting blocks lead to large lateral gradients. We regard the latter case and solve it by shifting the range shifting block far upstream in conjunction with a collimating aperture close to the patient. The experiments of the current work are based on a commercial proton therapy treatment head designed for several delivery modes. In a research environment of the spot-scanning delivery mode a range shifter is inserted downstream of the scanning magnets in a slot which is usually employed only in a scattering delivery mode. This configuration is motivated by equations assuming a simple model of proton transport. In the experiments lateral dose planes are acquired with a scintillation screen and radiochromic films. Dose distributions are calculated with the Monte Carlo dose engine of the RayStation treatment planning system. We demonstrate that proton fields with 80%–20% lateral dose fall-off values between 1.4 mm and 4.0 mm can be achieved for water equivalent depths between 0 cm and 10 cm. The simulated lateral dose profiles agree with the experimental dose profiles. The sharpening of the field edges is set off by a broadening of the proton spots towards the center of the fields. This limits the clinical application mainly to small fields for which the distal and proximal conformality is of minor importance.