Monte Carlo (MC) calculations are a fundamental tool for the investigation of ionization chambers (ICs) in radiation fields, and for calculations in the scope of IC reference dosimetry. Geant4, as used for the toolkit TOPAS, is a major general purpose code, generally suitable for investigating ICs in primary proton beams. To provide reliable results, the impact of parameter settings and the limitations of the underlying condensed history (CH) algorithm need to be known. A Fano cavity test was implemented in Geant4 (10.03.p1) for protons, based on the existing version for electrons distributed with the Geant4 release. This self-consistent test allows the calculation to be compared with the expected result for the typical IC-like geometry of an air-filled cavity surrounded by a higher density material. Various user-selectable parameters of the CH implementation in the EMStandardOpt4 physics-list were tested for incident proton energies between 30 and 250 MeV. Using TOPAS (3.1.p1) the influence of production cuts was investigated for bare air-cavities in water, irradiated by primary protons. Detailed IC geometries for an NACP-02 plane-parallel chamber and an NE2571 Farmer-chamber were created. The overall factor fQ as a ratio between the dose-to-water and dose to the sensitive air-volume was calculated for incident proton energies between 70 and 250 MeV. The Fano test demonstrated the EMStandardOpt4 physics-list with the WentzelIV multiple scattering model as appropriate for IC calculations. If protons start perpendicular to the air cavity, no further step-size limitations are required to pass the test within 0.1%. For an isotropic source, limitations of the maximum step length within the air cavity and its surrounding as well as a limitation of the maximum fractional energy loss per step were required to pass within 0.2%. A production cut of ⩽5 μ m or ∼15 keV for all particles yielded a constant result for fQ of bare air-filled cavities. The overall factor fQ for the detailed NACP-02 and NE2571 chamber models calculated with TOPAS agreed with the values of Gomà et al (2016 Phys. Med. Biol . 61 2389) within statistical uncertainties (1 σ ) of <0.3% for almost all energies with a maximum deviation of 0.6% at 250 MeV for the NE2571. The selection of hadronic scattering models ( QGSP_BIC versus QGSP_BERT ) in TOPAS impacted the results at the highest energies by 0.3% ± 0.1%. Based on the Fano cavity test, the Geant4/TOPAS Monte Carlo code, in its investigated version, can provide reliable results for IC calculations. Agreement with the detailed IC models and the published values of Gomà et al can be achieved when production cuts are reduced from the TOPAS default values. The calculations confirm the reported agreement of Gomà et al for with IAEA-TRS398 values within the given uncertainties. An additional uncertainty for the MC-calculated of ∼0.3% by hadronic interaction models should be considered.
To assess if apertures shall be mounted upstream or downstream of a range shifting block if these field-shaping devices are combined with the pencil-beam scanning delivery technique (PBS). The lateral dose fall-off served as a benchmark parameter. Both options realizing PBS-with-apertures were compared to the uniform scanning mode. We also evaluated the difference regarding the out-of-field dose caused by interactions of protons in beam-shaping devices. The potential benefit of the downstream configuration over the upstream configuration was estimated analytically. Guided by this theoretical evaluation a mechanical adapter was developed which transforms the upstream configuration provided by the proton machine vendor to a downstream configuration. Transversal dose profiles were calculated with the Monte-Carlo based dose engine of the commercial treatment planning system RayStation 6. Two-dimensional dose planes were measured with an ionization chamber array and a scintillation detector at different depths and compared to the calculation. Additionally, a clinical example for the irradiation of the orbit was compared for both PBS options and a uniform scanning treatment plan. Assuming the same air gap the lateral dose fall-off at the field edge at a few centimeter depth is 20% smaller for the aperture-downstream configuration than for the upstream one. For both options of PBS-with-apertures the dose fall-off is larger than in uniform scanning delivery mode if the minimum accelerator energy is 100 MeV. The RayStation treatment planning system calculated the width of the lateral dose fall-off with an accuracy of typically 0.1 mm–0.3 mm. Although experiments and calculations indicate a ranking of the three delivery options regarding lateral dose fall-off, there seems to be a limited impact on a multi-field treatment plan.
Proton therapy makes use of the favorable depth-dose distribution with its characteristic Bragg peak to spare normal tissue distal of the target volume. A steep dose gradient would be desired in lateral dimensions, too. The widespread spot scanning delivery technique is based, however, on pencil-beams with in-air spot full-widths-at-half-maximum of typically 1 cm or more. This hampers the sparing of organs-at-risk if small-scale structures adjacent to the target volume are concerned. The trimming of spot scanning fields with collimating apertures constitutes a simple measure to increase the transversal dose gradient. The current study describes the clinical implementation of brass apertures in conjunction with the pencil-beam scanning delivery mode at a horizontal, clinical treatment head based on commercial hardware and software components. Furthermore, clinical cases, which comprised craniopharyngiomas, re-irradiations and ocular tumors, were evaluated. The dosimetric benefits of 31 treatment plans using apertures were compared to the corresponding plans without aperture. Furthermore, an overview of the radiation protection aspects is given. Regarding the results, robust optimization considering range and setup uncertainties was combined with apertures. The treatment plan optimizations followed a single-field uniform dose or a restricted multi-field optimization approach. Robustness evaluation was expanded to account for possible deviations of the center of the pencil-beam delivery and the mechanical center of the aperture holder. Supplementary apertures improved the conformity index on average by 15.3%. The volume of the dose gradient surrounding the PTV (evaluated between 80 and 20% dose levels) was decreased on average by 17.6%. The mean dose of the hippocampi could be reduced on average by 2.9 GyRBE. In particular cases the apertures facilitated a sparing of an organ-at-risk, e.g. the eye lens or the brainstem. For six craniopharyngioma cases the inclusion of apertures led to a reduction of the mean dose of 1.5 GyRBE (13%) for the brain and 3.1 GyRBE (16%) for the hippocampi.
Some clinical indications require small fields with sharp lateral dose gradients, which is technically challenging in proton beam therapy. This holds especially true for low-range fields applied with the spot scanning technique, where large beam profiles entering from the beam-line or the insertion of range shifting blocks lead to large lateral gradients. We regard the latter case and solve it by shifting the range shifting block far upstream in conjunction with a collimating aperture close to the patient. The experiments of the current work are based on a commercial proton therapy treatment head designed for several delivery modes. In a research environment of the spot-scanning delivery mode a range shifter is inserted downstream of the scanning magnets in a slot which is usually employed only in a scattering delivery mode. This configuration is motivated by equations assuming a simple model of proton transport. In the experiments lateral dose planes are acquired with a scintillation screen and radiochromic films. Dose distributions are calculated with the Monte Carlo dose engine of the RayStation treatment planning system. We demonstrate that proton fields with 80%–20% lateral dose fall-off values between 1.4 mm and 4.0 mm can be achieved for water equivalent depths between 0 cm and 10 cm. The simulated lateral dose profiles agree with the experimental dose profiles. The sharpening of the field edges is set off by a broadening of the proton spots towards the center of the fields. This limits the clinical application mainly to small fields for which the distal and proximal conformality is of minor importance.
Pencil beam scanning (PBS) proton therapy enables better dose conformality for complex anatomical geometries than passive proton scattering techniques, but is more susceptible to organ motion. This becomes an issue when treating moving tumours in the thorax or abdomen. Novel four-dimensional treatment planning approaches have been developed to increase the robustness of PBS plans against motion. However, their efficacy still needs to be examined by means of 4D dynamically accumulated dose (4DDD) analyses. This study investigates the potential use of 4D robust optimisation to maintain sufficient target coverage in the presence of organ motion, while sparing surrounding healthy tissue, for hepatocellular carcinoma (HCC). The liver is particularly suited to study motion interplay effects since the treatment region exhibits smaller density gradients and more homogeneous tissue than targets in the thorax, making it less prone to range errors. A facility-specific beam time model, developed and experimentally validated previously, was used for the clinical evaluation. 4DDD analyses of eleven target volumes did not show a significant improvement of the target coverage using 4D robust optimisation, but a reduction of the dose to close-by organs at risk. Interplay effects were averaged out for the applied fractionation scheme of 15 fractions. Contrary to PBS, passive double scattering (DS) plans yielded homogeneous 4DDD dose distributions in a single fraction. But, in some cases, they exceeded organ at risk dose limits, which were only satisfied in PBS. The average normal liver dose could be decreased by almost 6% compared to non-robustly optimised PBS plans and by 16% compared to DS plans when implementing 4D robust optimisation. Except for some very small tumours with large motion amplitudes, 4D robustly optimised PBS plans were found to be clinically acceptable even without supplementary motion mitigation techniques.
Despite the increased risk of subsequent primary tumors (SPTs) external beam radiation (EBRT) may be the only therapeutic option to preserve a retinoblastoma eye. Due to their physical properties, proton beam therapy (PBT) offers the possibility to use the effectiveness of EBRT in tumor treatment and to decisively reduce the treatment-related morbidity. We report our experiences of PBT as rescue therapy in a retrospectively studied cohort of 15 advanced retinoblastoma eyes as final option for eye-preserving therapy. The average age at the initiation of PBT was 35 (14–97) months, mean follow-up was 22 (2–46) months. Prior to PBT, all eyes were treated with systemic chemotherapy and a mean number of 7.1 additional treatments. Indication for PBT was non-feasibility of intra-arterial chemotherapy (IAC) in 10 eyes, tumor recurrence after IAC in another 3 eyes and diffuse infiltrating retinoblastoma in 2 eyes. Six eyes (40%) were enucleated after a mean time interval of 4.8 (1–8) months. Cataract formation was the most common complication affecting 44.4% of the preserved eyes, yet 77.8% achieved a visual acuity of >20/200. Two of the 15 children treated developed metastatic disease during follow-up, resulting in a 13.3% metastasis rate. PBT is a useful treatment modality as a rescue therapy in retinoblastoma eyes with an eye-preserving rate of 60%. As patients are at lifetime risk of SPTs consistent monitoring is mandatory.