Maria Katarzyna Kostka

Dr. Maria Katarzyna Kostka

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
MBMagdalena Baborska-Narozny
Magdalena Baborska-Narozny
MKMaria Katarzyna Kostka
Maria Katarzyna Kostka
The article presents the results of measurements of temperature, relative humidity and CO2 concentration in six single-family houses’ bedrooms located in Poland, in Wrocław and vicinity, during two climatic seasons: summer–autumn and winter. Two buildings with natural ventilation (NV) were tested, three with mechanical ventilation with heat recovery (MV) and one with hybrid ventilation (HV)—mixed mode natural and mechanical. The behavior of residents regarding opening windows was analyzed and the influence of the changing internal and external conditions on their active reactions was examined. The analysis confirms and adds to the global discourse on the key impact of user behavior on securing healthy indoor air quality in housing, regardless of ventilation system or building energy standard. A disconnect exists between the observed window opening practices and typical design principles, assuming adjustment to a given ventilation system or changing weather conditions. The observations showed that in both analyzed seasons it was possible to obtain a good quality internal environment, in terms of CO2 level, regardless of the ventilation system used in the building. However, unfavorable results were observed for one bedroom, in which the inhabitants do not adapt their behavior to local technical conditions. Taking into account the level of relative humidity (RH), much higher values were observed in the NV bedrooms in both analyzed periods. The obtained results were divided into IAQ classes in accordance with the EN 16798-1. The recorded values of the internal temperature confirm the significant influence of the location of the room in the building and the actions taken by the residents.

24 May 2017
Verified
Conference Paper
Open access
PDF file
MKMaria Katarzyna Kostka
Maria Katarzyna Kostka
E3S Web of Conferences, open access proceedings in environment, energy and earth sciences

4 January 2022 in Energies
Verified
Journal Article
Open access
PDF file
MKMaria Katarzyna Kostka
Maria Katarzyna Kostka
AZAgnieszka Zając
Agnieszka Zając
This article presents the impact of climate change on air treatment processes and energy demand in a selected air-conditioning system. The analysis was performed for a system supplying rooms with pre-treated primary air. Further treatment occurred directly in the rooms with individual devices such as fan coils or chilled beams. The analysis of the second stage of air treatment was not part of this study. The calculations were made for the city of Warsaw, where, according to the climate analysis for the period 1961–2020, an increase in outside temperature by 0.4 °C per decade and an increase in air humidity by 0.2 g/kg per decade were observed. The system analysis was divided into two stages. The first, including calculations made for monthly average climate data for the entire period of 1961–2020, shows changes in the energy demand of the system, resulting from progressive climate change. This analysis confirmed the general tendency of increasing demand for cooling energy and decreasing demand for heating energy, which is also observed in many other regions of the world. The second stage, based on calculations for hourly climate data in selected years, is an analysis of the operation of all elements of the system equipment. Research has identified areas that will have an increasing impact on the energy efficiency of the whole air condition system during further climate change.

7 November 2017 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
MKMaria Katarzyna Kostka
Maria Katarzyna Kostka
MSMałgorzata Szulgowska–Zgrzywa
Małgorzata Szulgowska–Zgrzywa
The parameters of the outside air in Poland cause that in winter it is reasonable to use a mechanical ventilation equipped with a heat recovery exchanger. The time of spring, autumn, summer evenings and nights are often characterized by the parameters of the air, which allow for a natural ventilation and reduce the electricity consumption. The article presents the possibilities of energy consumption reduction for three energy standards of buildings located in Poland, ventilated by a change–over hybrid system. The analysis was prepared on the assumption that the air–to–water heat pump is the heat source for the buildings.


11 August 2025 in Energies
Verified
Journal Article
Open access
PDF file
MKMaria Katarzyna Kostka
Maria Katarzyna Kostka
ZPZuzanna Prokopowicz
Zuzanna Prokopowicz
MBMagdalena Baborska-Narozny
Magdalena Baborska-Narozny
Hybrid ventilation is indicated as one of the effective methods of maintaining thermal comfort and indoor air quality and reducing energy consumption in buildings. It assumes the capacity to switch between natural and mechanical ventilation, allowing the most efficient use of the outdoor air potential. This article aims to quantify the impact of changing ventilation system, from natural to hybrid, on indoor air parameters and air change rates in a bedroom of a single-family house. The distinct aspects of this study include longitudinal measurement over three years, natural ventilation substituted by hybrid ventilation halfway into the monitoring period, and unaltered building and user characteristics. The analysis is based on measurements of temperature, relative humidity, CO2 concentration, and window opening for three seven-month measurement periods from September 1 to March 31. The measurements are complemented by in-depth user feedback and an audit of the building structure and installed HVAC systems. A clear correlation was observed between the values of relative humidity and carbon dioxide concentration and the type of ventilation strategy. A significant influence of residents’ behavior on the achieved indoor air parameters was observed.