Atthaillah Atthaillah

Mr. Atthaillah Atthaillah

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2021 in Buildings
Verified
Journal Article
Open access
PDF file
RMRizki A. Mangkuto
Rizki A. Mangkuto
MKMochamad Donny Koerniawan
Mochamad Donny Koerniawan
SASri Rahma Apriliyanthi
Sri Rahma Apriliyanthi
ILIrma Handayani Lubis
Irma Handayani Lubis
AAAtthaillah Atthaillah
Atthaillah Atthaillah
Beta ParamitaBeta Paramita
Beta Paramita
Optimisation of shading devices in buildings is a broadly investigated topic; however, most studies only focus on a single façade orientation, since the observed buildings are typically located in high latitude regions. However, in tropical regions, optimisation of all façade orientations is required due to the relatively high solar radiation and long sunshine duration. While adaptive shading devices are a promising solution, they are not without disadvantages, and as such a combination of adaptive shading devices and a fixed shading device shall be considered. This research therefore aims to design the optimum internal shading devices on four façade orientations of a high-rise office building in a tropical city, considering fixed and adaptive shading design options, and to determine the impact on annual daylight performance using computational modelling and simulation. The simulation is carried out under: (1) fixed design option, focusing on the numbers and width of slats; and (2) adaptive design option, focusing on the slat angle on various conditions. It is found that both sDA300/50% and ASE1000,250 are only influenced by the orientation. Under the fixed design option, the sDA300/50% and ASE1000,250 targets can be achieved only on the north and south façades, and accordingly the adaptive design option shall be implemented on the east and west façades. Overall, this study contributes to knowledge regarding the optimisation of shading devices in high-rise buildings in the tropics, considering the daylight admission from the four cardinal orientations.

13 June 2022 in Buildings
Verified
Journal Article
Open access
PDF file
AAAtthaillah Atthaillah
Atthaillah Atthaillah
RMRizki A. Mangkuto
Rizki A. Mangkuto
MKMochamad Donny Koerniawan
Mochamad Donny Koerniawan
Brian YuliartoBrian Yuliarto
Brian Yuliarto
External shading devices are an important design feature in tropical buildings, particularly for climate mitigation. However, the interaction between the depth and elevation of the shading devices and their impact on indoor daylight performance is not fully understood, especially for the case of tropical buildings with bilateral openings. This study therefore aims to evaluate the design possibilities of external shading devices with various depth and elevation in terms of daylight performance for the case of tropical school classrooms with bilateral openings in an Indonesian city. A computational simulation method using Radiance is utilized to perform annual daylight metrics calculations. Geometry, material, and simulation settings are prepared using the Ladybug tool under Grasshopper for four building orientations, namely 0°, 45°, 90°, and 135°. Sensitivity and uncertainty analyses are conducted for all design combinations. The results show that the interaction between a shading device’s depth and elevation is unique, depending on the building orientation and the availability of direct sunlight. In general, shading elevation is more influential, compared to shading depth, on the observed daylight metrics and the combined objective functions at all orientations.

13 December 2019 in LANGKAU BETANG: JURNAL ARSITEKTUR
Verified
Journal Article
Open access
PDF file
AAAtthaillah Atthaillah
Atthaillah Atthaillah
ABAndik Bintoro
Andik Bintoro
Studi ini melakukan evaluasi pencahayaan alami pada ruang belajar Sekolah Dasar Negeri 2 dan 6 Banda Sakti, Lhokseumawe. Sekolah tersebut berada pada lokasi urban padat dan merupakan sekolah dengan bangunan terluas di kecamatan Banda Sakti. Ada 36 (tiga puluh enam) ruang kelas yang dilakukan simulasi pencahayaan alami pada objek studi ini. Simulasi pencahayaan alami dilakukan dengan metrik useful daylight illuminance (UDI). Metrik ini menggunakan data cuaca lokasi objek penelitian dalam hal ini data cuaca Kota Lhokseumawe dalam format energyplus weather (EPW) file. Pemodelan untuk simulasi dilakukan dengan piranti Rhinoceros, sementara algoritma simulasi dibuat menggunakan Grasshopper dengan tambahan plugin Ladybug Tools. Ladybug Tools memberikan akses ke engine simulasi Daysim yang merupakan perangkat simulasi pencahayaan alami yang tervalidasi. Pada penelitian ini ketegori UDI terpenuhi dialterasi sesuai dengan standar pencahayaan alami disarankan dalam SNI 03-6197 yaitu 250-750 Lux untuk ruangan yang digunakan pada bangunan pendidikan dalam hal ini sekolah dasar. Hasil menunjukkan tidak ada ruang kelas yang dikategorikan baik pada SDN 2 dan 6 Banda Sakti. Hanya terdapat 29 (dua puluh sembilan) kelas dengan kategori cukup dan 7 (tujuh) ruang dengan kategori kurangUSEFUL DAYLIGHT ILLUMINANCE (UDI) IN ELEMENTARY SCHOOL CLASSROOMS IN TROPICAL HIGH DENSITY URBAN AREA (CASE STUDY: SD NEGERI 2 AND 6 BANDA SAKTI, LHOKSEUMAWE, ACEH, INDONESIA) This study evaluated the daylight distribution within classrooms at Sekolah Dasar Negeri 2 and 6 Banda Sakti, Lhokseumawe. The school is located in high-density urban area, and it was the largest state elementary school building in Banda Sakti. 36 (thirty-six) classrooms were simulated for its daylight performance. The simulation utilized useful daylight illuminance (UDI) metric. The metric used the local weather file for Lhokseumawe in energyplus weather (EPW) format. Modeling for simulation utilized Rhinoceros; further, the simulation algorithm was created using Grasshopper with the extension of Ladybug Tools. Ladybug Tools opened access to a Daysim, a validated daylight simulation engine. In this study, the useful daylight was referenced to SNI 03-6197, which was 250-750 Lux for educational spaces at this study classrooms for the elementary school. The result showed there was none of the classroom fallen under a good category. 29 (twenty-nine) classrooms was under insufficient category and 7 (seven) classrooms under a bad category

10 July 2017 in NALARs
Verified
Journal Article
Open access
PDF file
AAAtthaillah Atthaillah
Atthaillah Atthaillah
MIMuhammad Iqbal
Muhammad Iqbal
ISIman Saputra Situmeang
Iman Saputra Situmeang
ABSTRAK Penelitian ini melakukan investigasi performa pencahayaan alami pada Gedung Program Studi Arsitektur Fakultas Teknik (PAFT) Universitas malikussaleh. Berdasarkan observasi pada gedung PAFT, ruangan-ruangan pada bangunan cenderung gelap dan memakai bantuan pencahayaan buatan walaupun pada siang hari, serta memiliki lahan sempit sehingga cahaya alaminya terhalang oleh bangunan perimeter. Tujuan dari penelitian ini adalah untuk menganalisa performa pencahayaan alami khususnya faktor pencahayaan alami (daylight factor) pada gedung PAFT dan memberikan solusi desain untuk meningkatkan performa pencahayaan alaminya. Metode penelitian dilakukan melalui simulasi Komputer (computer simulation) dengan software Velux Daylight Visualizer versi 2.0 untuk perhitungan faktor pencahayaan alami. Hasil menunjukkan bahwa permasalahan disebabkan oleh beberapa faktor diantaranya adalah kedalaman ruang, posisi ruang, pemilihan material bukaan, penempatan bukaan yang tidak sesuai, kondisi sekitar bangunan (penghalang bangunan), dan Window Wall Ratio (WWR) yang kurang memadai. Selanjutnya, penelitian ini memberikan solusi seperti meningkatkan WWR (menambah dan memperluas bukaan), mengganti warna interiordengan warna yang lebih cerah seperti warna putih, mengganti material bukaan dengan nilai Tvis lebih tinggi (0,850) dan menambahkan shading devices pada tempat-tempat yang dianggap Membutuhkan untuk menghindari efek silau berlebihan dalam ruangan. Kata kunci: Pencahayaan Alami, Faktor Pencahayaan Alami, Velux Daylight Visualiser 2.0, Simulasi Komputer ABSTRACT Daylighting provided significant benefits such as visual comfort and energy saving for a building. In addition, it improved productivity and welbeing of its occupants. As an educational building for architecture, the building of Prodi Arsitektur Fakultas Teknik (PAFT) Universitas Malikussaleh, needed to pay attention to its daylighting performance. As observed, on the one hand, spaces within the building relatively dark and it utilised electric lighting during working hours, on the other, it was made worse by narrow site surrounded with perimeter buildings at close distances. The aim of this study was to analyse daylighting performance within PAFT building, particularly, daylight factor (DF).  Furthermore, this research offered some solutions to improve daylight performance within PAFT building. Computer simulation were adopted with Velux Daylight Visualizer Version 2.0 for DF calculation. Result showed, majority of spaces within PAFT building did not meet standard as required by Standar Nasional Indonesia (SNI). The causes for the condition were depth of spaces, mispositioning of particular spaces within PAFT building, incorrect glass selection for openings, inappropriate opening positioning, reasonably close distance of adjacent building and insufficient window wall ratio (WWR). The possible solutions for the situation were increasing the WWR, change interior into a brighter color, replaced all of glasses with higher Tvis values and provided shading devices where appropriate.  Keywords: Daylighting, Daylight Factor, Velux Daylight Visualiser 2.0, Computer Simulation 

20 December 2021 in International Journal of Technology
Verified
Journal Article
Closed access
FHFahmi Nur Hakim
Fahmi Nur Hakim
YMYana Muhamadinah
Yana Muhamadinah
AAAtthaillah Atthaillah
Atthaillah Atthaillah
RMRizki A. Mangkuto
Rizki A. Mangkuto
ASAnugrah S. Sudarsono
Anugrah S. Sudarsono
This study evaluated the building performance of a hypothetical elementary school classroom considering its annual energy consumption, daylight criteria, and adaptive thermal comfort in Lhokseumawe, Indonesia. Variations in building materials, construction, and horizontal shading features were evaluated for the most optimal design solution. The aim was to optimize the multi-performance criteria as an integrated sustainable design solution for a typical classroom in Indonesia. To achieve this objective, the study utilized a computational simulation method using Rhinoceros, Grasshopper, and Ladybug Tools platforms. The optimization was conducted with Galapagos, an engine based on a genetic algorithm. The results suggest that the optimal solution achieved 100% sDA300/50% and more than 96% UDI100-3000lx. The annual thermal comfort percentage was also increased to over 90%, while the energy consumption was reduced by 20% compared to the baseline design.

1 January 2022
Verified
Book Chapter
Closed access
PDF file
AAAtthaillah Atthaillah
Atthaillah Atthaillah
RMRizki A. Mangkuto
Rizki A. Mangkuto
MKMochamad Donny Koerniawan
Mochamad Donny Koerniawan