Background/Objectives: The purpose of this study was to preoperatively estimate the four-strand hamstring graft size in a White Caucasian population, using anthropometric data. Methods: This was a prospective study of a consecutive series of fifty patients with anterior cruciate ligament (ACL) rupture, who were scheduled for reconstruction using hamstring autografts; however, one of them was ultimately not enrolled according to the exclusion criteria (49 patients in total). Preoperatively, age, sex, weight, body mass index (BMI), length, and diameter of the contralateral thigh, length of the harvested gracilis/semitendinosus tendons, and length and thickness of the four-stranded graft were recorded. Graft diameter and length were dependent variables, measured via a graft sizer and a ruler, respectively. Quantitative variables were described with mean ± SD (correlated in a pairwise manner with Pearson’s r correlation). Qualitative variables were described with an absolute count (relative % percent) per categorical level, and their dependency on any quantitative (dependent) variable was assessed via Student’s t-test. Results: The mean lengths of the gracilis and semitendinosus were 25.6 ± 3.2 cm and 28.4 ± 3.3 cm, respectively, and they were positively correlated with the length of the four-strand hamstring graft along with the patients’ height and thigh length. Conclusions: The use of anthropometric data can assist in the prediction of the hamstring autograft size, aiding the selection of an appropriate graft type. The four-strand hamstring graft length was related to the gracilis, semitendinosus, and thigh length. The patients’ height was related to the graft length and diameter.
The main aim of this case report is to thoroughly describe the steps of diagnosis and treatment in the rare incidence of patellar tendon gouty tophus. The case of a 53-year-old man manual worker who was treated with open excision of the lesion, following failure of extended medical treatment with rheumatological input, is presented. Surgical treatment led to full restoration of the patient's knee function. Open or arthroscopic surgery is a viable option for the unusual case of intratendinous patellar gouty deposition if the patient fails medical management. Medical treatment should still be the mainstay.
Introduction A significant percentage of patients require re-revision surgery regardless of the demonstrated durable short- and mid-term clinical results using metaphyseal sleeves in revision total knee arthroplasty (TKA). The aim of this study was to identify the association between sleeve alignment and contact zones, with loosening in patients with revision TKA. Materials & Methods Of a series of 103 patients who underwent revision TKA, at a mean follow-up of eight years, six patients were re-revised for tibial loosening. These patients were compared with 19 unrevised control subjects in a 1:3 ratio. We calculated and compared the cumulative number of contact zones between the porous-coated part of the sleeve and bone on immediate postoperative X-rays between re-revised and unrevised patients. The main hypothesis was that neutral positioning and absolute circumferential contact between trabecular metaphyseal bone and porous-coated part of the sleeve would lead to a better outcome. Results The use of a conservative (nonparametric) approach indeed revealed better circumferential contact between trabecular metaphyseal bone and porous-coated part of the sleeve among the survivors, i.e., survivors: median (interquartile range [IQR]): 3 (2-4); failures: 3 ( 1-3), p = 0.003 (Mann-Whitney [MW] test). The difference was borderline significant for coronal alignment, i.e., survivors: median (IQR): -1 (-4 to 2); failures: 0 (-1 to 3), p = 0.0569 (MW test). Conclusion A circumferential bony contact of the metaphyseal sleeve would lead to better survival of the revision implant, whereas the degree of varus fixation did not seem to influence the longevity of the implant.