1 April 2018 in Experimental Thermal and Fluid Science
Verified
Journal Article
Open access
EZE. Zorgani
E. Zorgani
HAHameed Alawadi
Hameed Alawadi
WYW. Yan
W. Yan
SAS. Al-Lababid
S. Al-Lababid
HYH. Yeung
H. Yeung
CFC.P. Fairhurst
C.P. Fairhurst
Solids transport in multiphase systems is one of the issues under the umbrella of ‘‘flow assurance.’ But unlike issues such as waxes and hydrates, solids transport has received relatively little interest to date. The overall aim of this research was to investigate the fluid viscosity effects on sand particle transport characteristics in pipelines. Investigations were conducted using a 3-inch test facility for oil and a 4- inch flow loop for water and CMC experiments. Three oil viscosities were used including 105 cP, 200 cP and 340 cP. The sand used had a density of 2650 kg/m3 and a median diameter of 0.2 mm. The sand loadings were 50 lb/1000 bbl and 200lb/1000bbl. Based on the King et al (2000) sand minimum transport condition definition, the sand transport velocity for water, CMC solutions and oil (105 cP, 200 cP and 340 cP) were determined by visual observation and camera. The observed sand/oil flow regimes were compared. For oil/sand tests, it was observed that the dominant regime when approaching the critical sand transport velocity was the sliding sand bed, sand dunes were notably absent. However, for water and 7 cP CMC solution, sand dunes and sliding sand bed regimes were observed when approaching the sand transport velocity. For 20cP CMC solution, it was observed that the sand particles in the region between the main dunes were very active compared to those within the dunes

24 May 2017 in The Canadian Journal of Chemical Engineering
Verified
Journal Article
Closed access
PDF file
JSJing Shi
Jing Shi
HAHameed Alawadi
Hameed Alawadi
HYHoi Yeung
Hoi Yeung

6 March 2022 in Buildings
Verified
Journal Article
Open access
PDF file
HAHameed Alawadi
Hameed Alawadi
AAAli Alajmi
Ali Alajmi
HAHosny Abou-Ziyan
Hosny Abou-Ziyan
In this paper, the thermal performance of residential building envelopes including thermal bridges (TBs) in a hot climate, using four different exterior wall types, is modelled and assessed. TBs at the junctions between columns and walls and between walls and slabs of the ground floor, roof, and intermediate floors are considered. The tested wall types are classical (two layers of cement blocks with insulation in between), autoclaved aerated concrete bearing (AAC-B), AAC column and beam (AAC-CB), and exterior insulation and finish system (EIFS). The results indicated that thermal bridges have a considerable effect and determine the best external wall type which was the EIFS that has a continuous exterior insulation. EIFS proved to reduce the heat transmission with the outdoor environment for residential buildings by 101.8, 51.2, and 13.9% than the AAC-CB, AAC-B, and classical walls, respectively. Thermal bridges effect on the building envelope using the EIFS is insignificant as the thermal resistance of the envelope and wall differs by less than 1% for small areas. The overall heat transfer coefficients for small buildings are larger than those for large buildings by 8–26%. As the number of intermediate floors increases from 1 to 50, the envelope overall heat transfer coefficient increases by 4.5% for the EIFS, 14.1% for classical, and 19.5% for AAC-CB walls. The AAC-CB, as the common practice wall structure in many hot climate countries, has the lowest performance among the tested wall types.

20 June 2022 in Energies
Verified
Journal Article
Open access
PDF file
HAHameed Alawadi
Hameed Alawadi
AAAli Alajmi
Ali Alajmi
HAHosny Abou-Ziyan
Hosny Abou-Ziyan
In this paper, the effect of house envelopes including thermal bridges on the daily, monthly, and annual consumption of the air conditioning system of a detached house and an attached house, with a façade in the east, west, north, or south direction, is investigated; moreover, the capacity of the air conditioning system is calculated for detached and attached houses based on the maximum hourly peak load during severe weather conditions. The four tested house envelopes are exterior insulation and finish system (EIFS), autoclaved aerated concrete block (AAC-B), classical (cement blocks with insulation in between), and AAC column and beam (AAC-CB). The work is conducted using a method that combines the finite element method (COMSOL Multiphysics), building simulation (EnergyPlus), and the Engineering Equation Solver (EES) programs. The results indicated that the annual consumption of the air conditioning system using AAC-B, classical, and AAC-CB envelopes is larger than that of EIFS by about 3.74, 11.53, and 20.70% for the detached house, and 1.8, 2.9%, and 6.7% for the attached house, respectively. The annual consumption of the air conditioner of the detached house is larger than the average consumption of the attached house by about 25.3, 27.7, 35.8, and 41.7% for EIFS, AAC-B, classical, and AAC-CB house envelopes, respectively. Using the different façade directions of the attached house, the average effect of the house envelope type on the air conditioning system capacity is about 8.84%, with a standard deviation of 0.466%.

28 July 2018 in Microsystem Technologies
Verified
Journal Article
Closed access
PDF file
MMM. A. Mahmoud
M. A. Mahmoud
MAMosab A. Alrahmani
Mosab A. Alrahmani
HAHameed Alawadi
Hameed Alawadi