Ali Alajmi

Dr. Ali Alajmi

College of Technological Studies, Kuwait City, Al ‘Āşimah, Kuwait

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Energy Conversion and Management
Verified
Journal Article
Closed access
AAAli Alajmi
Ali Alajmi
SRSantiago Rodríguez
Santiago Rodríguez
DSDavid Sailor
David Sailor

1 June 2016 in International Journal of Sustainable Built Environment
Verified
Journal Article
Open access
JWJonathan Wright
Jonathan Wright
AAAli Alajmi
Ali Alajmi
The main aim of this paper is to find the appropriate set of Genetic Algorithm (GA), control parameters that attain the optimum, or near optimum solutions, in a reasonable computational time for constrained building optimization problem. Eight different combinations of control parameters of binary coded GA were tested in a hypothetical building problem by changing 80 variables. The results showed that GA performance was insensitive to some GA control parameter values such as crossover probability and mutation rate. However, population size was the most influential control parameter on the GA performance. In particular, the population sizes (15 individuals) require less computational time to reach the optimum solution. In particular, a binary encoded GA with relatively small population sizes can be used to solve constrained building optimization problems within 750 building simulation calls.

6 March 2022 in Buildings
Verified
Journal Article
Open access
PDF file
HAHameed Alawadi
Hameed Alawadi
AAAli Alajmi
Ali Alajmi
HAHosny Abou-Ziyan
Hosny Abou-Ziyan
In this paper, the thermal performance of residential building envelopes including thermal bridges (TBs) in a hot climate, using four different exterior wall types, is modelled and assessed. TBs at the junctions between columns and walls and between walls and slabs of the ground floor, roof, and intermediate floors are considered. The tested wall types are classical (two layers of cement blocks with insulation in between), autoclaved aerated concrete bearing (AAC-B), AAC column and beam (AAC-CB), and exterior insulation and finish system (EIFS). The results indicated that thermal bridges have a considerable effect and determine the best external wall type which was the EIFS that has a continuous exterior insulation. EIFS proved to reduce the heat transmission with the outdoor environment for residential buildings by 101.8, 51.2, and 13.9% than the AAC-CB, AAC-B, and classical walls, respectively. Thermal bridges effect on the building envelope using the EIFS is insignificant as the thermal resistance of the envelope and wall differs by less than 1% for small areas. The overall heat transfer coefficients for small buildings are larger than those for large buildings by 8–26%. As the number of intermediate floors increases from 1 to 50, the envelope overall heat transfer coefficient increases by 4.5% for the EIFS, 14.1% for classical, and 19.5% for AAC-CB walls. The AAC-CB, as the common practice wall structure in many hot climate countries, has the lowest performance among the tested wall types.

20 June 2021 in International Journal of Sustainable Engineering
Verified
Journal Article
Closed access
AAAli Alajmi
Ali Alajmi
Eco-houses play a pivotal role in reducing greenhouse gas emissions. To implement such a concept, the current Conventional Design Process (CDP) needs to be improved. Thus, Integrated Design Process (IDP) was recently introduced to the buildings sector. IDP involves early stakeholders in a systematic approach to achieve performance targets. In this study, IDP was implemented in a single-family house, targeting efficient houses with minimum/no cost. Many energy efficiency strategies (EESs), such as envelop insulation, orientation, window properties, and efficient air-conditioning system, have been applied. These energy strategies predicted a substantial energy reduction where the energy use intensity (EUI) would fall from 182 to 72 kWh/m2.year. In addition, solar renewable energy, domestic solar hot water (DSHW), and photovoltaic (PV) panels (10 kW) saved 18.78 MWh/year. Besides, water efficiency strategies (WESs) are anticipated to save 217,581 gallons/year due to the use of a water recycling unit, low flowrate faucets, and efficient shower systems, all of which have been proposed. All the recommended energy efficiency strategies (EESs) and water efficiency strategies (WESs) had a simple payback period of fewer than 10 years and proved their cost feasibility over their life-cycle. Moreover, a considerable CO₂ emission avoidance (117 tons/year) was attained.


20 June 2022 in Energies
Verified
Journal Article
Open access
PDF file
HAHameed Alawadi
Hameed Alawadi
AAAli Alajmi
Ali Alajmi
HAHosny Abou-Ziyan
Hosny Abou-Ziyan
In this paper, the effect of house envelopes including thermal bridges on the daily, monthly, and annual consumption of the air conditioning system of a detached house and an attached house, with a façade in the east, west, north, or south direction, is investigated; moreover, the capacity of the air conditioning system is calculated for detached and attached houses based on the maximum hourly peak load during severe weather conditions. The four tested house envelopes are exterior insulation and finish system (EIFS), autoclaved aerated concrete block (AAC-B), classical (cement blocks with insulation in between), and AAC column and beam (AAC-CB). The work is conducted using a method that combines the finite element method (COMSOL Multiphysics), building simulation (EnergyPlus), and the Engineering Equation Solver (EES) programs. The results indicated that the annual consumption of the air conditioning system using AAC-B, classical, and AAC-CB envelopes is larger than that of EIFS by about 3.74, 11.53, and 20.70% for the detached house, and 1.8, 2.9%, and 6.7% for the attached house, respectively. The annual consumption of the air conditioner of the detached house is larger than the average consumption of the attached house by about 25.3, 27.7, 35.8, and 41.7% for EIFS, AAC-B, classical, and AAC-CB house envelopes, respectively. Using the different façade directions of the attached house, the average effect of the house envelope type on the air conditioning system capacity is about 8.84%, with a standard deviation of 0.466%.