Evangelos Giannitsis

Prof. Evangelos Giannitsis

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2010 in Clinical Chemistry
Verified
Journal Article
Open access
PDF file
EGEvangelos Giannitsis
Evangelos Giannitsis
KKKerstin Kurz
Kerstin Kurz
KHKlaus Hallermayer
Klaus Hallermayer
JJJochen Jarausch
Jochen Jarausch
AJAllan S Jaffe
Allan S Jaffe
HKHugo A Katus
Hugo A Katus
Background: We report the development of a novel high-sensitivity cardiac troponin T (hs-cTnT) assay, a modification of the Roche fourth-generation cTnT assay, and validation of the analytical performance of this assay. Methods: Validation included testing of analytical sensitivity, specificity, interferences, and precision. We established the 99th percentile cutoff from healthy reference populations (n = 616). In addition, we studied differences in time to a positive result when using serial measurements of hs-cTnT vs cTnT in patients with a confirmed diagnosis of non-ST elevation myocardial infarction (non-STEMI). Results: The hs-cTnT assay had an analytical range from 3 to 10 000 ng/L. At the 99th percentile value of 13.5 ng/L, the CV was 9% using the Elecsys® 2010 analyzer. The assay was specific for cTnT without interferences from human cTnI or cTnC, skeletal muscle TnT, or hemoglobin concentrations up to 1000 mg/L, above which falsely lower values would be expected. When the assay was evaluated clinically, a hs-cTnT higher than the 99th percentile concentration identified a significantly higher number of patients with non-STEMI on presentation (45 vs 20 patients, P = 0.0004) compared with cTnT, and a final diagnosis of non-STEMI was made in 9 additional patients (55 vs 46 patients, P = 0.23) after serial sampling. Time to diagnosis was significantly shorter using hs-cTnT compared with cTnT [mean 71.5 (SD 108.7) min vs 246.9 (82.0) min, respectively; P < 0.01]. Conclusions: The analytical performance of hs-cTnT complies with the ESC-ACCF-AHA-WHF Global Task Force recommendations for use in the diagnosis of MI.

1 April 2010 in Clinical Chemistry
Verified
Journal Article
Open access
PDF file
EGEvangelos Giannitsis
Evangelos Giannitsis
MBMeike Becker
Meike Becker
KKKerstin Kurz
Kerstin Kurz
GHGeorg Hess
Georg Hess
DZDietmar Zdunek
Dietmar Zdunek
HKHugo A Katus
Hugo A Katus
Background: We sought to determine the diagnostic performance of the new high-sensitivity cardiac troponin T (hs-cTnT) assay for early detection of non–ST-segment myocardial infarction (NSTEMI) in patients with acute coronary syndrome. Methods: We enrolled patients with retrospectively confirmed unstable angina or NSTEMI and an initially negative cTnT concentration and compared the performance of baseline concentrations and serial changes in concentration within 3 and 6 h. Percentage change criteria included ≥20% δ change and ROC-optimized value. Results: Based on the standard fourth-generation cTnT result of ≥0.03 μg/L, an evolving NSTEMI was diagnosed in 26 patients, and 31 patients were classified as having unstable angina. With the use of the hs-cTnT assay at the 99th-percentile cutoff, the percentage of NSTEMI cases detected increased gradually from 61.5% on presentation to 100% within 6 h, and the overall number of MI diagnoses increased by 34.6% (35 vs 26 cases). A δ change ≥20% or ≥ROC-optimized value of >117% within 3 h or ≥243% within 6 h yielded a specificity of 100% at sensitivities between 69% and 76%. The standard cTnT at the 99th percentile was less sensitive than hs-cTnT for early diagnosis of MI on presentation, and follow-up samples obtained within the initial 3 h demonstrated very low specificity of cTnT compared with hs-cTnT. Conclusions: The high-sensitivity cTnT assay increases the number of NSTEMI diagnoses and enables earlier detection of evolving NSTEMI. A doubling of the hs-cTnT concentration within 3 h in the presence of a second concentration ≥99th percentile is associated with a positive predictive value of 100% and a negative predictive value of 88%.

1 January 2012 in Clinical Chemistry
Verified
Journal Article
Open access
PDF file
MMMatthias Mueller
Matthias Mueller
MBMoritz Biener
Moritz Biener
MVMehrshad Vafaie
Mehrshad Vafaie
SDSusanne Doerr
Susanne Doerr
TKTill Keller
Till Keller
EGEvangelos Giannitsis
Evangelos Giannitsis
BACKGROUND: We evaluated kinetic changes of high-sensitivity cardiac troponin T (hs-cTnT) in patients with acute coronary syndrome (ACS) and patients with hs-cTnT increases not due to ACS to rule in or rule out non–ST-segment elevation myocardial infarction (STEMI). METHODS: hs-cTnT was measured serially in consecutive patients presenting to the emergency department. Patients with ACS who had at least 2 hs-cTnT measurements within 6 h and non-ACS patients with hs-cTnT concentrations above the 99th percentile value (14 ng/L) were enrolled to compare absolute and relative kinetic changes of hs-cTnT. RESULTS: For discrimination of non-STEMI (n = 165) in the entire study population (n = 784), the absolute δ change with the ROC-optimized value of 9.2 ng/L yielded an area under the curve of 0.898 and was superior to all relative δ changes (P < 0.0001). The positive predictive value for the absolute δ change was 48.7%, whereas the negative predictive value was 96.5%. In a specific ACS population with exclusion of STEMI (n = 342), the absolute δ change with the ROC-optimized value of 6.9 ng/L yielded a positive predictive value of 82.8% and a negative predictive value of 93.0%. In comparison to the ≥20% relative δ change, the ROC-optimized absolute δ change demonstrated a significantly added value for the entire study population and for the ACS cohort (net reclassification index 0.331 and 0.499, P < 0.0001). CONCLUSIONS: Absolute δ changes appear superior to relative δ changes in discriminating non-STEMI. A rise or fall of at least 9.2 ng/L in the entire study population and 6.9 ng/L in selected ACS patients seems adequate to rule-out non-STEMI. However, δ-values are useful to rule-in non-STEMI only in a specific ACS population.

1 January 2015 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
FAFlorian Andre
Florian Andre
HSHenning Steen
Henning Steen
PMPhilipp Matheis
Philipp Matheis
MWMaria Westkott
Maria Westkott
KBKristin Breuninger
Kristin Breuninger
SBSebastian J Buss
Sebastian J Buss
Assessment of left (LV) ventricular function is one of the most important tasks of cardiovascular magnetic resonance (CMR). Impairment of LV deformation is a strong predictor of cardiovascular outcome in various cardiac diseases like ischemic heart disease or cardiomyopathies. The aim of the study was to provide reference values for myocardial deformation derived from the CMR feature tracking imaging (FTI) algorithm in a reference population of healthy volunteers. FTI was applied to standard short axis and 2-, 3- and 4-chamber views of vector-ECG gated CMR cine SSFP sequences of 150 strictly selected healthy volunteers (75 male/female) of three age tertiles (mean age 45.8yrs). Global peak and mean radial, circumferential and longitudinal endo- and myocardial systolic strain values as well as early diastolic strain rates were measured using FTI within a standard protocol on a 1.5T whole body MR scanner. Global peak systolic values were 36.3 ± 8.7% for radial, −27.2 ± 4.0% for endocardial circumferential, −21.3 ± 3.3% for myocardial circumferential, −23.4 ± 3.4% for endocardial longitudinal and −21.6 ± 3.2% for myocardial longitudinal strain. Global peak values were -2.1 ± 0.5s−1 for radial, 2.1 ± 0.6s−1 for circumferential endocardial, 1.7 ± 0.5s−1 for circumferential myocardial, 1.8 (1.5-2.2)s−1 for longitudinal endocardial, 1.6 (1.4-2.0)s−1 for longitudinal myocardial early diastolic strain rates. Men showed a higher radial strain than women whereas the circumferential and longitudinal strains were lower resulting in less negative values. Circumferential and longitudinal strain rates were significantly higher in female subjects. Radial strain increased significantly with age whereas the diastolic function measured by the radial, circumferential and longitudinal strain rates showed a decrease. The coefficients of variation determined in ten further subjects, who underwent two CMR examinations within 12 days, were −4.8% for circumferential and −4.5% for longitudinal endocardial mean strains. Myocardial deformation analysis using FTI is a novel technique and robust when applied to standard cine CMR images providing the possibility of a reliable, objective quantification of global LV deformation. Since strain values and strain rates differed partly between genders as well as between age groups, the application of specific reference values as provided by this study is recommendable.

8 August 2023 in Circulation
Verified
Journal Article
Closed access
LLLorenz H. Lehmann
Lorenz H. Lehmann
MHMarkus B. Heckmann
Markus B. Heckmann
GBGuillaume Bailly
Guillaume Bailly
DFDaniel Finke
Daniel Finke
Adrien ProcureurAdrien Procureur
Adrien Procureur
LBLauren A Baldassarre
Lauren A Baldassarre
BACKGROUND: Immune checkpoint inhibitors (ICIs) are approved for multiple cancers but can result in ICI-associated myocarditis, an infrequent but life-threatening condition. Elevations in cardiac biomarkers, specifically troponin-I (cTnI), troponin-T (cTnT), and creatine kinase (CK), are used for diagnosis. However, the association between temporal elevations of these biomarkers with disease trajectory and outcomes has not been established. METHODS: We analyzed the diagnostic accuracy and prognostic performances of cTnI, cTnT, and CK in patients with ICI myocarditis (n=60) through 1-year follow-up in 2 cardio-oncology units (APHP Sorbonne, Paris, France and Heidelberg, Germany). A total of 1751 (1 cTnT assay type), 920 (4 cTnI assay types), and 1191 CK sampling time points were available. Major adverse cardiomyotoxic events (MACE) were defined as heart failure, ventricular arrhythmia, atrioventricular or sinus block requiring pacemaker, respiratory muscle failure requiring mechanical ventilation, and sudden cardiac death. Diagnostic performance of cTnI and cTnT was also assessed in an international ICI myocarditis registry. RESULTS: Within 72 hours of admission, cTnT, cTnI, and CK were increased compared with upper reference limits (URLs) in 56 of 57 (98%), 37 of 42 ([88%] P =0.03 versus cTnT), and 43 of 57 ([75%] P <0.001 versus cTnT), respectively. This increased rate of positivity for cTnT (93%) versus cTnI ([64%] P <0.001) on admission was confirmed in 87 independent cases from an international registry. In the Franco–German cohort, 24 of 60 (40%) patients developed ≥1 MACE (total, 52; median time to first MACE, 5 [interquartile range, 2–16] days). The highest value of cTnT:URL within the first 72 hours of admission performed best in terms of association with MACE within 90 days (area under the curve, 0.84) than CK:URL (area under the curve, 0.70). A cTnT:URL ≥32 within 72 hours of admission was the best cut-off associated with MACE within 90 days (hazard ratio, 11.1 [95% CI, 3.2–38.0]; P <0.001), after adjustment for age and sex. cTnT was increased in all patients within 72 hours of the first MACE (23 of 23 [100%]), whereas cTnI and CK values were less than the URL in 2 of 19 (11%) and 6 of 22 (27%) of patients ( P <0.001), respectively. CONCLUSIONS: cTnT is associated with MACE and is sensitive for diagnosis and surveillance in patients with ICI myocarditis. A cTnT:URL ratio <32 within 72 hours of diagnosis is associated with a subgroup at low risk for MACE. Potential differences in diagnostic and prognostic performances between cTnT and cTnI as a function of the assays used deserve further evaluation in ICI myocarditis.

1 April 2016 in International Journal of Cardiology
Verified
Journal Article
Closed access
MMMatthias Mueller-Hennessen
Matthias Mueller-Hennessen
BLBertil Lindahl
Bertil Lindahl
EGEvangelos Giannitsis
Evangelos Giannitsis
MBMoritz Biener
Moritz Biener
MVMehrshad Vafaie
Mehrshad Vafaie
CMChristian Mueller
Christian Mueller