Cardiac troponin testing is central to the diagnosis of acute myocardial infarction. We evaluated a sensitive troponin I assay for the early diagnosis and risk stratification of myocardial infarction. In a multicenter study, we determined levels of troponin I as assessed by a sensitive assay, troponin T, and traditional myocardial necrosis markers in 1818 consecutive patients with suspected acute myocardial infarction, on admission and 3 hours and 6 hours after admission. For samples obtained on admission, the diagnostic accuracy was highest with the sensitive troponin I assay (area under the receiver-operating-characteristic curve [AUC], 0.96), as compared with the troponin T assay (AUC, 0.85) and traditional myocardial necrosis markers. With the use of the sensitive troponin I assay (cutoff value, 0.04 ng per milliliter) on admission, the clinical sensitivity was 90.7%, and the specificity was 90.2%. The diagnostic accuracy was virtually identical in baseline and serial samples, regardless of the time of chest-pain onset. In patients presenting within 3 hours after chest-pain onset, a single sensitive troponin I assay had a negative predictive value of 84.1% and a positive predictive value of 86.7%; these findings predicted a 30% rise in the troponin I level within 6 hours. A troponin I level of more than 0.04 ng per milliliter was independently associated with an increased risk of an adverse outcome at 30 days (hazard ratio, 1.96; 95% confidence interval, 1.27 to 3.05; P=0.003). The use of a sensitive assay for troponin I improves early diagnosis of acute myocardial infarction and risk stratification, regardless of the time of chest-pain onset.
Acute chest pain is one of the most common reasons patients seek care in an emergency department.1 Early identification of individuals at high and intermediate risk for myocardial ischemia is crucial because they benefit the most from early and aggressive treatment.2
Data regarding high-sensitivity troponin concentrations in patients presenting to the emergency department with symptoms suggestive of myocardial infarction may be useful in determining the probability of myocardial infarction and subsequent 30-day outcomes.
BACKGROUND: We evaluated kinetic changes of high-sensitivity cardiac troponin T (hs-cTnT) in patients with acute coronary syndrome (ACS) and patients with hs-cTnT increases not due to ACS to rule in or rule out non–ST-segment elevation myocardial infarction (STEMI). METHODS: hs-cTnT was measured serially in consecutive patients presenting to the emergency department. Patients with ACS who had at least 2 hs-cTnT measurements within 6 h and non-ACS patients with hs-cTnT concentrations above the 99th percentile value (14 ng/L) were enrolled to compare absolute and relative kinetic changes of hs-cTnT. RESULTS: For discrimination of non-STEMI (n = 165) in the entire study population (n = 784), the absolute δ change with the ROC-optimized value of 9.2 ng/L yielded an area under the curve of 0.898 and was superior to all relative δ changes (P < 0.0001). The positive predictive value for the absolute δ change was 48.7%, whereas the negative predictive value was 96.5%. In a specific ACS population with exclusion of STEMI (n = 342), the absolute δ change with the ROC-optimized value of 6.9 ng/L yielded a positive predictive value of 82.8% and a negative predictive value of 93.0%. In comparison to the ≥20% relative δ change, the ROC-optimized absolute δ change demonstrated a significantly added value for the entire study population and for the ACS cohort (net reclassification index 0.331 and 0.499, P < 0.0001). CONCLUSIONS: Absolute δ changes appear superior to relative δ changes in discriminating non-STEMI. A rise or fall of at least 9.2 ng/L in the entire study population and 6.9 ng/L in selected ACS patients seems adequate to rule-out non-STEMI. However, δ-values are useful to rule-in non-STEMI only in a specific ACS population.