Hossein Rouhani

Dr. Hossein Rouhani

Department of Mechanical Engineering, University of Alberta, Edmonton, Alberta, Canada
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2013 in Gait & Posture
Verified
Journal Article
Closed access
BMBenoit Mariani
Benoit Mariani
HRHossein Rouhani
Hossein Rouhani
XCXavier Crevoisier
Xavier Crevoisier
Kamiar AminianKamiar Aminian
Kamiar Aminian


1 April 2007 in Expert Systems with Applications
Verified
Journal Article
Closed access
HRHossein Rouhani
Hossein Rouhani
MJMahdi Jalili
Mahdi Jalili
BABabak Nadjar Araabi
Babak Nadjar Araabi
WEWolfgang Eppler
Wolfgang Eppler
CLCaro Lucas
Caro Lucas

1 July 2010 in Gait & Posture
Verified
Journal Article
Closed access
HRHossein Rouhani
Hossein Rouhani
JFJ. Favre
J. Favre
XCX. Crevoisier
X. Crevoisier
Kamiar AminianKamiar Aminian
Kamiar Aminian

1 March 2020 in Medical Engineering & Physics
Verified
Journal Article
Closed access
NANoamani Alireza
Noamani Alireza
MNMilad Nazarahari
Milad Nazarahari
JLJustin C Lewicke
Justin C Lewicke
Albert VetteAlbert Vette
Albert Vette
HRHossein Rouhani
Hossein Rouhani
Observational balance tests (e.g., Berg Balance Scale) are used to evaluate fall-risk. However, they tend to be subjective, and their reliability and sensitivity can be limited. The use of in-lab equipment for objective balance evaluation has not been common in clinical practice, due to the requirement of an equipped lab space. While inertial measurement units (IMUs) enable objective out-of-lab balance assessment, their accuracy has not been validated. This study aims to investigate the accuracy of IMUs against in-lab equipment for characterizing standing balance. Ten non-disabled individuals participated in a two-minute standing test on a force-plate. Four approaches were used for estimating inter-segmental moments and center of pressure (COP) position in a four-segment model: (1) camera-based bottom-up approach; (2) camera-based top-down approach; (3) IMU-based (accelerometer) top-down approach; and (4) IMU-based (accelerometer and gyroscope) top-down approach. Approaches 2 to 4 resulted in high accuracy compared to the reference, Approach 1. The root-mean-square errors in estimating the segments' orientation, ground reaction forces, COP position, and joint moments were smaller than 0.3°, 0.2 N/kg, 1.5 mm, and 0.016N·m/kg, respectively. Since no significant differences were observed between the accuracy of Approaches 3 and 4, only accelerometer recordings are needed and could be recommended for monitoring standing balance.

1 June 2015 in Clinical Biomechanics
Verified
Journal Article
Closed access
MMMatija Milosevic
Matija Milosevic
KMKei Masani
Kei Masani
MKMeredith J. Kuipers
Meredith J. Kuipers
HRHossein Rouhani
Hossein Rouhani
MVMary C. Verrier
Mary C. Verrier
MPMilos Popovic
Milos Popovic