Alison McGregor

Prof. Alison McGregor

Professor of Musculoskeletal Biodynamics
orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
YAYewande Adesida
Yewande Adesida
EPEnrica Papi
Enrica Papi
Alison McGregorAlison McGregor
Alison McGregor
The aim of this review was to understand the use of wearable technology in sport in order to enhance performance and prevent injury. Understanding sports biomechanics is important for injury prevention and performance enhancement and is traditionally assessed using optical motion capture. However, such approaches are limited by capture volume restricting assessment to a laboratory environment, a factor that can be overcome by wearable technology. A systematic search was carried out across seven databases where wearable technology was employed to assess kinetic and kinematic variables in sport. Articles were excluded if they focused on sensor design and did not measure kinetic or kinematic variables or apply the technology on targeted participants. A total of 33 articles were included for full-text analysis where participants took part in a sport and performed dynamic movements relating to performance monitored by wearable technologies. Inertial measurement units, flex sensors and magnetic field and angular rate sensors were among the devices used in over 15 sports to quantify motion. Wearable technology usage is still in an exploratory phase, but there is potential for this technology to positively influence coaching practice and athletes’ technique.

1 May 2024 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
TZTianyu Zhou
Tianyu Zhou
DSDavid Salman
David Salman
Alison McGregorAlison McGregor
Alison McGregor
Background: Low back pain (LBP) is a significant health problem worldwide, with a lifetime prevalence of 84% in the general adult population. To rationalise the management of LBP, clinical practice guidelines (CPGs) have been issued in various countries around the world. This study aims to identify and compare the recommendations of recent CPGs for the management of LBP across the world. Methods: MEDLINE, EMBASE, CINAHL, PEDro, and major guideline databases were searched from 2017 to 2022 to identify CPGs. CPGs focusing on information regarding the management and/or treatment of non-specific LBP were considered eligible. The quality of included guidelines was evaluated using the Appraisal of Guidelines for Research and Evaluation (AGREE) II instrument. Results: Our analysis identified a total of 22 CPGs that met the inclusion criteria, and were of middle and high methodological quality as assessed by the AGREE II tool. The guidelines exhibited heterogeneity in their recommendations, particularly in the approach to different stages of LBP. For acute LBP, the guidelines recommended the use of non-steroidal anti-inflammatory drugs (NSAIDs), therapeutic exercise, staying active, and spinal manipulation. For subacute LBP, the guidelines recommended the use of NSAIDs, therapeutic exercise, staying active, and spinal manipulation. For chronic LBP, the guidelines recommended therapeutic exercise, the use of NSAIDs, spinal manipulation, and acupuncture. Conclusions: Current CPGs provide recommendations for almost all major aspects of the management of LBP, but there is marked heterogeneity between them. Some recommendations lack clarity and overlap with other treatments within the guidelines.

13 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SCSwathikan Chidambaram
Swathikan Chidambaram
YMYathukulan Maheswaran
Yathukulan Maheswaran
KPKian Patel
Kian Patel
VSViknesh Sounderajah
Viknesh Sounderajah
DHDaniel A. Hashimoto
Daniel A. Hashimoto
ADAra Darzi
Ara Darzi
Wearable technologies are small electronic and mobile devices with wireless communication capabilities that can be worn on the body as a part of devices, accessories or clothes. Sensors incorporated within wearable devices enable the collection of a broad spectrum of data that can be processed and analysed by artificial intelligence (AI) systems. In this narrative review, we performed a literature search of the MEDLINE, Embase and Scopus databases. We included any original studies that used sensors to collect data for a sporting event and subsequently used an AI-based system to process the data with diagnostic, treatment or monitoring intents. The included studies show the use of AI in various sports including basketball, baseball and motor racing to improve athletic performance. We classified the studies according to the stage of an event, including pre-event training to guide performance and predict the possibility of injuries; during events to optimise performance and inform strategies; and in diagnosing injuries after an event. Based on the included studies, AI techniques to process data from sensors can detect patterns in physiological variables as well as positional and kinematic data to inform how athletes can improve their performance. Although AI has promising applications in sports medicine, there are several challenges that can hinder their adoption. We have also identified avenues for future work that can provide solutions to overcome these challenges.

5 December 2012 in Sensors
Verified
Journal Article
Open access
PDF file
Jeroen BergmannJeroen Bergmann
Jeroen Bergmann
VCVikesh Chandaria
Vikesh Chandaria
Alison McGregorAlison McGregor
Alison McGregor
There has been a rising interest in wearable and implantable biomedical sensors over the last decade. However, many technologies have not been integrated into clinical care, due to a limited understanding of user-centered design issues. Little information is available about these issues and there is a need to adopt more rigorous evidence standards for design features to allow important medical sensors to progress quicker into clinical care. Current trends in patient preferences need to be incorporated at an early stage into the design process of prospective clinical sensors. The first comprehensive patient data set, discussing mobile biomedical sensor technology, is presented in this paper. The study population mainly consisted of individuals suffering from arthritis. It was found that sensor systems needed to be small, discreet, unobtrusive and preferably incorporated into everyday objects. The upper extremity was seen as the favored position on the body for placement, while invasive placement yielded high levels of acceptance. Under these conditions most users were willing to wear the body-worn sensor for more than 20 h a day. This study is a first step to generate research based user-orientated design criteria’s for biomedical sensors.

1 April 2014 in Gait & Posture
Verified
Journal Article
Open access
LDLynsey Duffell
Lynsey Duffell
DSDominic F.L. Southgate
Dominic F.L. Southgate
VGVivek Gulati
Vivek Gulati
Alison McGregorAlison McGregor
Alison McGregor
Gait adaptations in people with severe knee osteoarthritis (OA) have been well documented, with increased knee adduction moments (KAM) the most commonly reported parameter. Neuromuscular adaptations have also been reported, including reduced postural control. However these adaptations may be the result of morphological changes in the joint, rather than the cause. This study aimed to determine if people with early OA have altered gait parameters and neuromuscular adaptations. Gait and postural tasks were performed by 18 people with early medial knee OA and 18 age and gender-matched control subjects. Parameters measured were kinematics and kinetics during gait and postural tasks, and centre of pressure and electromyographic activity during postural tasks. OA subjects showed no differences in the gait parameters measured, however they demonstrated postural deficits during one-leg standing on both their affected and unaffected sides and altered hip adduction moments compared with controls. Increased activity of the gluteus medius of both sides (p<0.05), and quadriceps and hamstrings of the affected side (p<0.05) during one-leg standing compared with controls were also noted. This study has demonstrated that gait adaptations commonly associated with OA do not occur in the early stages, while neuromuscular adaptations are evident. These results may be relevant for early interventions to delay or prevent osteoarthritis in its early stages.

7 December 2009 in Journal of Back and Musculoskeletal Rehabilitation
Verified
Journal Article
Open access
PDF file
Alison McGregorAlison McGregor
Alison McGregor
DHD.W.L. Hukins
D.W.L. Hukins
Aim: To evaluate evidence for involvement of the lower limb in spinal function and low back pain (LBP). Design: A hypothesis based on a critical review of the relevant biomechanical and clinical literature. Results: The spine resembles an inverted pe