Devesh Barshilia

Dr. Devesh Barshilia

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 January 2024 in Nano Letters
Verified
Journal Article
Open access
DBDevesh Barshilia
Devesh Barshilia
JHJhen-Jie Huang
Jhen-Jie Huang
AKAkhil Chandrakanth Komaram
Akhil Chandrakanth Komaram
YCYi-Che Chen
Yi-Che Chen
CCChun-Da Chen
Chun-Da Chen
Guo-En ChangGuo-En Chang
Guo-En Chang
Sepsis, a life-threatening inflammatory response, demands economical, accurate, and rapid detection of biomarkers during the critical "golden hour" to reduce the patient mortality rate. Here, we demonstrate a cost-effective waveguide-enhanced nanogold-linked immunosorbent assay (WENLISA) based on nanoplasmonic waveguide biosensors for the rapid and sensitive detection of procalcitonin (PCT), a sepsis-related inflammatory biomarker. To enhance the limit of detection (LOD), we employed sandwich assays using immobilized capture antibodies and detection antibodies conjugated to gold nanoparticles to bind the target analyte, leading to a significant evanescent wave redistribution and strong nanoplasmonic absorption near the waveguide surface. Experimentally, we detected PCT for a wide linear response range of 0.1 pg/mL to 1 ng/mL with a record-low LOD of 48.7 fg/mL (3.74 fM) in 8 min. Furthermore, WENLISA has successfully identified PCT levels in the blood plasma of patients with sepsis and healthy individuals, offering a promising technology for early sepsis diagnosis.

27 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
WHWei-Ting Hsu
Wei-Ting Hsu
YLYu-Cheng Lin
Yu-Cheng Lin
HYHuang-Chin Yang
Huang-Chin Yang
DBDevesh Barshilia
Devesh Barshilia
PCPo-Liang Chen
Po-Liang Chen
Guo-En ChangGuo-En Chang
Guo-En Chang
Particle plasmon resonance (PPR), or localized surface plasmon resonance (LSPR), utilizes intrinsic resonance in metal nanoparticles for sensor fabrication. While diffraction grating waveguides monitor bioaffinity adsorption with out-of-plane illumination, integrating them with PPR for biomolecular detection schemes remains underexplored. This study introduces a label-free biosensing platform integrating PPR with a diffraction grating waveguide. Gold nanoparticles are immobilized on a glass slide in contact with a sample, while a UV-assisted embossed diffraction grating is positioned opposite. The setup utilizes diffraction in reflection to detect changes in the environment’s refractive index, indicating biomolecular binding at the gold nanoparticle surface. The positional shift of the diffracted beam, measured with varying refractive indices of sucrose solutions, shows a sensitivity of 0.97 mm/RIU at 8 cm from a position-sensitive detector, highlighting enhanced sensitivity due to PPR–diffraction coupling near the gold nanoparticle surface. Furthermore, the sensor achieved a resolution of 3.1 × 10−4 refractive index unit and a detection limit of 4.4 pM for detection of anti-DNP. The sensitivity of the diffracted spot was confirmed using finite element method (FEM) simulations in COMSOL Multiphysics. This study presents a significant advancement in biosensing technology, offering practical solutions for sensitive, rapid, and label-free biomolecule detection.

21 September 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
DBDevesh Barshilia
Devesh Barshilia
AKHIL CHANDRAKANTH KOMARAMAKHIL CHANDRAKANTH KOMARAM
AKHIL CHANDRAKANTH KOMARAM
Lai-Kwan ChauLai-Kwan Chau
Lai-Kwan Chau
Guo-En ChangGuo-En Chang
Guo-En Chang
DNA is fundamental for storing and transmitting genetic information. Analyzing DNA or RNA base sequences enables the identification of genetic disorders, monitoring gene expression, and detecting pathogens. Traditional detection techniques like polymerase chain reaction (PCR) and next-generation sequencing (NGS) have limitations, including complexity, high cost, and the need for advanced computational skills. Therefore, there is a significant demand for enzyme-free and amplification-free strategies for rapid, low-cost, and sensitive DNA detection. DNA biosensors, especially those utilizing plasmonic nanomaterials, offer a promising solution. This study introduces a novel DNA-functionalized waveguide-enhanced nanoplasmonic optofluidic biosensor using a nanogold-linked sorbent assay for enzyme-free and amplification-free DNA detection. Integrating plasmonic gold nanoparticles (AuNPs) with a glass planar waveguide (WG) and a microfluidic channel, fabricated through cost-effective, vacuum-free methods, the biosensor achieves specific detection of complementary target DNA sequences. Utilizing a sandwich architecture, AuNPs labeled with detection DNA probes enhance sensitivity by altering evanescent wave distribution and inducing plasmon resonance modes. The biosensor demonstrated exceptional performance in DNA detection, achieving a limit of detection (LOD) of 33.1 fg/mL (4.36 fM) with a rapid response time of approximately 8 min. This ultrasensitive, rapid, and cost-effective biosensor exhibits minimal background nonspecific adsorption, making it highly suitable for clinical applications and early disease diagnosis. The innovative design and fabrication processes offer significant advantages for mass production, presenting a viable tool for precise disease diagnostics and improved clinical outcomes.

27 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
YCYen-Song Chen
Yen-Song Chen
DBDevesh Barshilia
Devesh Barshilia
CHChia-Jui Hsieh
Chia-Jui Hsieh
HLHsun-Yuan Li
Hsun-Yuan Li
WHWen-Hsin Hsieh
Wen-Hsin Hsieh
Guo-En ChangGuo-En Chang
Guo-En Chang
Guided mode resonance (GMR) sensors are known for their ultrasensitive and label-free detection, achieved by assessing refractive index (RI) variations on grating surfaces. However, conventional systems often require manual adjustments, which limits their practical applicability. Therefore, this study enhances the practicality of GMR sensors by introducing an optimized detection system based on the Jones matrix method. In addition, finite element method simulations were performed to optimize the GMR sensor structure parameter. The GMR sensor chip consists of three main components: a cyclic olefin copolymer (COC) substrate with a one-dimensional grating structure of a period of ~295 nm, a height of ~100 nm, and a ~130 nm thick TiO2 waveguide layer that enhances the light confinement; an integrated COC microfluidic module featuring a microchannel; and flexible tubes for efficient sample handling. A GMR sensor in conjunction with a specially designed system was used to perform RI measurements across varying concentrations of sucrose. The results demonstrate its exceptional performance, with a normalized sensitivity (Sn) and RI resolution (Rs) of 0.4 RIU−1 and 8.15 × 10−5 RIU, respectively. The proposed detection system not only offers improved user-friendliness and cost efficiency but also delivers an enhanced performance, making it ideal for scientific and industrial applications, including biosensing and optical metrology, where precise polarization control is crucial.

16 March 2026 in Optical Materials Express
Verified
Journal Article
Closed access
KLKuo-Chih Lee
Kuo-Chih Lee
RWRuei-Jhang Wang
Ruei-Jhang Wang
YJYue-Tong Jheng
Yue-Tong Jheng
DBDevesh Barshilia
Devesh Barshilia
YCYu Cheng
Yu Cheng
Guo-En ChangGuo-En Chang
Guo-En Chang
Group-IV GeSn alloys have gained significant attention as an attractive material system for silicon photonics. Thermal annealing provides an efficient route to improve the crystalline quality and overall performance of GeSn layers. Here, we present a comparative study on the effects of rapid thermal annealing (RTA) and microwave annealing (MWA) on GeSn samples grown on Si via Ge buffer layers containing ∼6.3% Sn under a compressive strain of 0.793%. Structural analysis reveals that RTA at ∼380 °C yields a modest strain relaxation of ∼20% and enhanced crystallinity. However, RTA at higher temperatures results in defect generation and a decrease in photoluminescence (PL) emission intensity. In contrast, MWA at a moderate power of ∼900 W achieves a higher strain relaxation of ∼27–28% while preserving both material quality and PL emission. This advantage is attributed to the more localized energy delivery and reduced thermal budget of MWA, which mitigates Sn diffusion and maintains alloy integrity. In addition, theoretical analysis of the strain-dependent band structure and spontaneous emission in GeSn further confirms that increased strain relaxation enhances the direct-gap character and radiative recombination. These findings demonstrate that MWA offers a more robust and scalable post-growth annealing route for optimizing GeSn layers while balancing strain engineering, optical performance, and material stability, thereby advancing the development of high-performance, complementary metal oxide semiconductor-compatible GeSn-based photonic devices.

7 July 2026 in Physica Scripta
Verified
Journal Article
Open access
DBDevesh Barshilia
Devesh Barshilia
APAbimanyu Jaya Prakash
Abimanyu Jaya Prakash
WHWen-Hsin Hsieh
Wen-Hsin Hsieh
Guo-En ChangGuo-En Chang
Guo-En Chang
We report on a low-cost, and highly sensitive waveguide-coupled metallic photonic crystal (WGMPC) optical sensor for real-time refractive index (RI) sensing applications. The proposed sensor endows enhanced light–matter interaction within a compact two-dimensional structure. The metallic photonic crystal structures are fabricated using a scalable nanoimprint-based process on a TiO 2 waveguide platform, ensuring high reproducibility and compatibility with large-area manufacturing. Finite-element simulations confirm strong electromagnetic field confinement at the metal–dielectric interface, indicating efficient plasmonic excitation and improved sensing performance. Experimental RI sensing, conducted using sucrose solutions, demonstrates a clear and linear intensity response over a broad RI range, along with good stability and reversibility. The sensor achieves a normalized sensitivity of 0.8051 ± 0.002579 RIU −1 and an RI resolution of 1.18 × 10 −4 RIU, highlighting its capability to detect small RI variations. These results validate the effectiveness of the proposed WGMPC platform as a low-cost and reliable optical sensing solution. Owing to its real-time response, reasonable sensitivity, and scalable fabrication, the sensor shows strong potential for point-of-care clinical and biosensing applications.