The rapid and sensitive detection of human C-reactive protein (CRP) in a point-of-care (POC) may be conducive to the early diagnosis of various diseases. Biosensors have emerged as a new technology for rapid and accurate detection of CRP for POC applications. Here, we propose a rapid and highly stable guided-mode resonance (GMR) optofluidic biosensing system based on intensity detection with self-compensation, which substantially reduces the instability caused by environmental factors for a long detection time. In addition, a low-cost LED serving as the light source and a photodetector are used for intensity detection and real-time biosensing, and the system compactness facilitates POC applications. Self-compensation relies on a polarizing beam splitter to separate the transverse-magnetic-polarized light and transverse-electric-polarized light from the light source. The transverse-electric-polarized light is used as a background signal for compensating noise, while the transverse-magnetic-polarized light is used as the light source for the GMR biosensor. After compensation, noise is drastically reduced, and both the stability and performance of the system are enhanced over a long period. Refractive index experiments revealed a resolution improvement by 181% when using the proposed system with compensation. In addition, the system was successfully applied to CRP detection, and an outstanding limit of detection of 1.95 × 10−8 g/mL was achieved, validating the proposed measurement system for biochemical reaction detection. The proposed GMR biosensing sensing system can provide a low-cost, compact, rapid, sensitive, and highly stable solution for a variety of point-of-care applications.
Guided mode resonance (GMR) sensors are known for their ultrasensitive and label-free detection, achieved by assessing refractive index (RI) variations on grating surfaces. However, conventional systems often require manual adjustments, which limits their practical applicability. Therefore, this study enhances the practicality of GMR sensors by introducing an optimized detection system based on the Jones matrix method. In addition, finite element method simulations were performed to optimize the GMR sensor structure parameter. The GMR sensor chip consists of three main components: a cyclic olefin copolymer (COC) substrate with a one-dimensional grating structure of a period of ~295 nm, a height of ~100 nm, and a ~130 nm thick TiO2 waveguide layer that enhances the light confinement; an integrated COC microfluidic module featuring a microchannel; and flexible tubes for efficient sample handling. A GMR sensor in conjunction with a specially designed system was used to perform RI measurements across varying concentrations of sucrose. The results demonstrate its exceptional performance, with a normalized sensitivity (Sn) and RI resolution (Rs) of 0.4 RIU−1 and 8.15 × 10−5 RIU, respectively. The proposed detection system not only offers improved user-friendliness and cost efficiency but also delivers an enhanced performance, making it ideal for scientific and industrial applications, including biosensing and optical metrology, where precise polarization control is crucial.
13 May 2026 in The International Journal of Advanced Manufacturing Technology