Marius Costel Balan

Dr. Marius Costel Balan

Technical University "Gheorghe Asachi" Iasi
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2022 in Materials
Verified
Journal Article
Open access
PDF file
GSGavril Sosoi
Gavril Sosoi
CACherifa Abid
Cherifa Abid
MBMarinela Barbuta
Marinela Barbuta
ABAndrei Burlacu
Andrei Burlacu
MBMarius Costel Balan
Marius Costel Balan
FRFabrice Rigollet
Fabrice Rigollet
The continuous growth of the concrete industry requires an increased quantity of cement and natural aggregates year after year, and it is responsible for a major part of the global CO2 emissions. These aspects led to rigorous research for suitable raw materials. Taking into account that these raw materials must have a sustainable character and also a low impact on environmental pollution, the replacement of the conventional components of concrete by residual waste can lead to these targets. This paper’s aim is to analyze the density, compressive strength and the thermal conductivity of nine concrete compositions with various rates of waste: four mixes with 10%, 20%, 40% and 60% chopped PET bottles aggregates and 10% fly ash as cement partial substitution; a mix with 60% waste polystyrene of 4–8 mm and 10% fly ash; a mix with 20% waste polystyrene of 4–8 mm, 10% waste polystyrene of 0–4 mm and 10% fly ash; a mix with 50% waste polystyrene of 4–8 mm, 20% waste polystyrene of 0–4 mm and 20% fly ash two mixes with 10% fly ash and 10% and 40% waste sawdust, respectively. Using 60% PET aggregates, 60% polystyrene granules of 4–8 mm, or 20% polystyrene of 0–4 mm together with 50% polystyrene of 4–8 mm led to the obtainment of lightweight concrete, with a density lower than 2000 kg/m3. These mixes also registered the best results from a thermal conductivity point of view, after the concrete mix with 40% saw dust. Regarding compressive strength, the mix with 10% PET obtained a result very close to the reference mix, while those with 20% PET, 40% PET, 30% polystyrene, and 10% saw dust, respectively, registered values between 22 MPa and 25 MPa, values appropriate for structural uses.

16 March 2023 in Materials
Verified
Journal Article
Open access
PDF file
RVRobert Stefan Vizitiu
Robert Stefan Vizitiu
ABAndrei Burlacu
Andrei Burlacu
CACherifa Abid
Cherifa Abid
MBMarius Costel Balan
Marius Costel Balan
ȘTȘtefănica Eliza Tansanu
Ștefănica Eliza Tansanu
NKNicoleta Elena Kaba
Nicoleta Elena Kaba
This study presents an experimental and numerical investigation into the efficiency of a two-stage heat recovery–storage system for reducing the thermal energy losses in the industry. The system is designed to recover and store waste thermal energy from residual fluids using heat pipes for recovery and an environmentally friendly phase change material for heat storage. Experimental investigation was conducted using water as the primary agent and varying the temperature between 60 °C, 65 °C, and 70 °C at a constant flow rate of 24 L/min. The secondary agent, also water, was used at an initial temperature of 10 °C and the flow rate was varied between 1 L/min, 2 L/min, and 3 L/min. The results show that the system had a peak efficiency of 78.1% and was able to recover a significant amount of thermal energy. This study demonstrates the potential of this system to reduce the thermal energy losses in the industry and highlight the importance of further research and development in this field, as the industry is responsible for approximately 14% of the total thermal energy losses and finding efficient ways to recover and store waste thermal energy is crucial to achieving sustainable energy consumption.

6 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RVRobert Stefan Vizitiu
Robert Stefan Vizitiu
ABAndrei Burlacu
Andrei Burlacu
CACherifa Abid
Cherifa Abid
TETurcanu EMILIAN
Turcanu EMILIAN
MBMarius Costel Balan
Marius Costel Balan
MBMarius Brănoaea
Marius Brănoaea
One of the biggest challenges the world is facing these days is to reduce the greenhouse gases emissions in order to prevent the global warming. Since a significant quantity of CO2 emissions is the result of the energy producing process required in industry or buildings, the waste heat recovery is an important aspect in the fight for preserving the planet. In this study, an innovative waste heat recovery system which can recover waste heat energy from cooling liquids used in industry or in different processes, was designed and subjected to experimental investigations. The equipment uses heat pipes to capture thermal energy from the residual fluids transiting the evaporator zone and transfer it to the cold water transiting the condenser zone. The efficiency of the heat exchanger was tested in 9 scenarios, by varying the temperature of the primary agent to 60, 65 and 70 °C and the volume flow rate of the secondary agent to 1, 2 and 3 L/min. The temperature of the secondary agent and the volume flow rate of the primary agent were kept constant at 10 °C, respectively 24 L/min. The results were later validated through numerical simulations, and confirmed that the equipment can easily recover waste thermal energy from used water with low and medium temperatures at very low costs compared to the traditional heat exchangers. The results were promising, revealing an efficiency of the equipment up to 76.7%.

4 September 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
RVRobert Stefan Vizitiu
Robert Stefan Vizitiu
ȘTȘtefănica Eliza Tansanu
Ștefănica Eliza Tansanu
ABAndrei Burlacu
Andrei Burlacu
CACherifa Abid
Cherifa Abid
MBMarius Costel Balan
Marius Costel Balan
NKNicoleta Elena Kaba
Nicoleta Elena Kaba
The implementation of energy-saving measures has a substantial and beneficial impact on the preservation of energy resources as well as the reduction of carbon dioxide emissions. This study focuses on the design and experimental analysis of a water-to-air heat recovery system aimed at capturing waste heat from wastewater and transferring it to a fresh cold air stream using heat pipe technology. The research problem addressed in this study is the efficient recovery of low-grade thermal energy from wastewater, which is often underutilized. The prototype heat recovery unit was designed, manufactured, and tested in the laboratory to assess its performance across various operating conditions. The experimental setup included a system where the primary agent, hot water, was heated to 60 °C and circulated through the evaporator section of the heat recovery unit, while the secondary agent, fresh air, was forced through the condenser section. The system’s performance was evaluated under different air velocities, ranging from 3.5 m/s to 4.5 m/s, corresponding to airflow rates of 207.1 m3/h and 268.6 m3/h, respectively. The study employed analytical methods alongside empirical testing to determine the effectiveness of the heat recovery system, with the global heat transfer coefficient calculated for different scenarios. The efficiency of the system varied between 25% and 51.6%, depending on the temperature and speed of the fresh air stream. The most significant temperature difference observed between the inflow and outflow of the fresh air stream was 16.8 °C, resulting in a thermal output of 1553 W. Additionally, the average (mean) overall heat transfer coefficient of the unit was calculated to be 49 W/m2 K, which aligns with values reported in the literature for similar systems. The results demonstrate the potential of the designed system for practical applications in energy conservation and carbon emission reduction.

15 August 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
ȘTȘtefănica Eliza Tansanu
Ștefănica Eliza Tansanu
CACherifa Abid
Cherifa Abid
ABAndrei Burlacu
Andrei Burlacu
RVRobert Stefan Vizitiu
Robert Stefan Vizitiu
MBMarius Costel Balan
Marius Costel Balan
In the transition to sustainable energy consumption, waste heat recovery and storage systems become key to advancing Europe’s energy efficiency and reducing carbon emissions, especially by harnessing thermal energy from low-temperature sources like wastewater. This study focuses on optimizing a heat recovery system that uses heat pipes for effective heat extraction and coconut oil as a phase change material for efficient thermal storage. A total of 12 numerical simulations were conducted to analyze the outcomes of varying operational parameters, including the diameter of the heat pipe, condenser size, secondary agent flow rate, coil length, and primary agent inlet temperature. The numerical findings indicate that reduced flow rates, in combination with smaller condenser diameters and increased primary agent temperatures, greatly improve the efficiency of heat absorption and transfer. Following a 4 h test period, the most successful outcome resulted in a melting fraction of 98.8% and a temperature increase of 18.95 °C in the output temperature of the secondary agent. In contrast, suboptimal conditions resulted in only a 2.21 °C rise and a 30.80% melting fraction. The study highlights the importance of component sizing and optimization, noting that strategic modifications and appropriate phase change materials can lead to highly efficient and scalable systems.

22 February 2019 in E3S Web of Conferences
Verified
Conference Paper
Open access
FTFlorin-Emilian Turcanu
Florin-Emilian Turcanu
MVMarina Verdeş
Marina Verdeş
VCVasilică Ciocan
Vasilică Ciocan
ABAndrei Burlacu
Andrei Burlacu
MBMarius Costel Balan
Marius Costel Balan
RVRobert Stefan Vizitiu
Robert Stefan Vizitiu
This paper presents the simulation method for evaluating the heating system from a church. The inside climate has been evaluated by measures of temperature and humidity taken in the winter season. The aim of the paper is to model and validate the indoor climate measures thought numerical analysis and to evaluate the heating system performance. The paper include a case study over and representative category of buildings, used as worship place that can contain heritage values. Nowadays, to conserve the historical heritage is a fact studied in many countries of Europe.