SANGHYUN LEE

Dr. SANGHYUN LEE


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2007 in Journal of Intelligent Material Systems and Structures
Verified
Journal Article
Closed access
SLSANGHYUN LEE
SANGHYUN LEE
KMKyung-Won Min
Kyung-Won Min
LCLan Chung
Lan Chung
SLSung-Kyung Lee
Sung-Kyung Lee
MLMyoung-Kyu Lee
Myoung-Kyu Lee
HLHo-Guen Lee
Ho-Guen Lee
In this study, the effects of bracing systems for installing a magnetorheological (MR) damper in a building structure on seismic response control are analytically and experimentally investigated. The performance of the toggle brace system which enables the installed damper to generate larger effective control force due to its response amplification mechanism than a conventional brace system is evaluated. In addition, the nonlinear velocity amplification factor for the toggle brace—MR damper system and the effect of toggle configuration are considered. Analytical and experimental results show that control performance can be enhanced using the toggle brace system especially for the case in which the MR damper installed using non-amplifying brace system cannot provide sufficient response reduction.

31 January 2018 in Shock and Vibration
Verified
Journal Article
Open access
PDF file
JRJi-Eun Roh
Ji-Eun Roh
MHMoo-Won Hur
Moo-Won Hur
HCHyun-Hoon Choi
Hyun-Hoon Choi
SLSANGHYUN LEE
SANGHYUN LEE
A multiaction hybrid damper (MHD) is designed to have independent hysteretic characteristics under small and large loading conditions, and its control performance for building structures excited by wind or earthquake load is verified. The MHD is composed of steel elements, two friction pads, and two lead rubber bearings (LRBs). Because the friction pads and the LRBs are in series connection, only the LRBs deform before the friction pad slippage occurs. After the friction slippage, the damper deformation concentrates on the friction pads. The initial stiffness and hysteresis are dependent on the properties of the LRB, and the maximum force is determined by the friction pad. Accordingly, the load‐deformation behaviors before/after the friction slippage can be independently designed to show optimal performance for a building structure subject to wind and earthquake loads. The cyclic loading tests of a full scale MHD were conducted to evaluate the multiaction behaviors and energy dissipation capacity of the MHD. The control performance of the MHD damper is analytically investigated by using a 20‐story steel structure subject to wind loads and a 15‐story RC structure excited by earthquake loads. The MHD damper showed good performance for reducing both the linear wind‐induced and nonlinear earthquake‐induced responses.

7 January 2019 in International Journal of Concrete Structures and Materials
Verified
Journal Article
Open access
PDF file
JHJae-Seung Hwang
Jae-Seung Hwang
JNJungtae Noh
Jungtae Noh
SLSANGHYUN LEE
SANGHYUN LEE
AKAhsan Kareem
Ahsan Kareem
Independent component analysis is one of the linear transformation methods based the techniques for separating blind sources from the output signals of the system. Recently, the method has been analytically applied to the identification of mode shapes and modal responses from the output signal of structures. This study aims to experimentally validate the blind source separation using ICA method and propose a novel method for identification of the modal parameters from the decomposed modal responses. The result of the experimental testing on the three-story steel scale model shows that the mode shapes obtained by ICA method are in good agreement with those by the analytical and peak-picking method in the frequency domain. Based on the robust mathematical model, ICA can calculate the natural frequency and damping ratio effectively using the probability distribution function of the instantaneous natural frequency determined by Hilbert transform of the decomposed modal responses and the change in the output covariance. Finally, the validity of the proposed method paves the way for more effective output-only modal identification for assessment of existing steel-concrete buildings.

13 November 2021 in Buildings
Verified
Journal Article
Open access
PDF file
SHSeok Jae Heo
Seok Jae Heo
SNSeunguk Na
Seunguk Na
MHMoo-Won Hur
Moo-Won Hur
SLSANGHYUN LEE
SANGHYUN LEE
In this study, the shape of a vertical expansion module with a rotary-type damping device is proposed. The external energy dissipation capacity is confirmed through experiments and the performance of the module is simulated. It can be easily applied to high-rise structures, as the module is directly supported by the bearing walls without the need for a separate base system. Additionally, as the damper can be replaced, it is possible to enhance seismic performance even after construction. The simulation results show that the rotary-type damper is more effective in reducing the displacement, shear force, and moment than free and fixed joints. In the pushover analysis of a system modeled using the moment hinge of the rotary damper of the joint, the best response reduction effect is obtained when the yield moment of the hinge is defined as 1% of the frame plastic moment. As a result of the analysis of the multi-degree-of-freedom system considering a harmonic load, we determined that it is efficient for the hinge to yield after the displacement, and the acceleration response of the resonant structure reaches steady state during the installation. In the multi-degree-of-freedom system with slab joints added to the analytical model, the displacement response decreased gradually as the natural period of the structure decreased and the joint increased. This provides evidence that the damper does not affect the overall behavior of the structure. The most important design factor of the rotary-type friction damper, shown through the experiment, is the relationship between the frictional surface and the tightening force of the bolt.

4 March 2019 in Journal of Asian Architecture and Building Engineering
Verified
Journal Article
Open access
JHJae-Seung Hwang
Jae-Seung Hwang
KLKang-Seok Lee
Kang-Seok Lee
MHMoo-Won Hur
Moo-Won Hur
SLSANGHYUN LEE
SANGHYUN LEE
In this study, we introduce a metal-wire Kagome truss damper and investigate its mechanical properties through theoretical analyses and experimental tests. The Kagome damper had high resistance to plastic buckling and low anisotropy. We propose an equation to estimate the yield strength of the damper, which was dependent on the geometric shape and thickness of the metal wire. We conducted cyclic shear loading tests to investigate the energy dissipation capacity and stiffness/strength degradation of the damper through repeated loading. Based on the hysteretic properties revealed by the tests, we found that modification of the ideal truss model with a hinged connection could predict the yield strength and stiffness of the damper. We present a numerical example to improve the seismic performance of a five-story reinforced concrete structure by installing Kagome dampers.

31 October 2021 in Journal of the Computational Structural Engineering Institute of Korea
Verified
Journal Article
Open access
SHSeok Jae Heo
Seok Jae Heo
SNSeunguk Na
Seunguk Na
SHSehee Han
Sehee Han
YSYoonsoo Shin
Yoonsoo Shin
SLSANGHYUN LEE
SANGHYUN LEE