Jungtae Noh

Dr. Jungtae Noh

Department of Architectural Engineering, Dankook University, Yongin, Gyeonggi-do, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2018 in Composite Structures
Verified
Journal Article
Closed access
JNJungtae Noh
Jungtae Noh
BGBehzad Ghadimi
Behzad Ghadimi
SRSalvatore Russo
Salvatore Russo
MJMichele John
Michele John

7 January 2019 in International Journal of Concrete Structures and Materials
Verified
Journal Article
Open access
PDF file
JHJae-Seung Hwang
Jae-Seung Hwang
JNJungtae Noh
Jungtae Noh
SLSANGHYUN LEE
SANGHYUN LEE
AKAhsan Kareem
Ahsan Kareem
Independent component analysis is one of the linear transformation methods based the techniques for separating blind sources from the output signals of the system. Recently, the method has been analytically applied to the identification of mode shapes and modal responses from the output signal of structures. This study aims to experimentally validate the blind source separation using ICA method and propose a novel method for identification of the modal parameters from the decomposed modal responses. The result of the experimental testing on the three-story steel scale model shows that the mode shapes obtained by ICA method are in good agreement with those by the analytical and peak-picking method in the frequency domain. Based on the robust mathematical model, ICA can calculate the natural frequency and damping ratio effectively using the probability distribution function of the instantaneous natural frequency determined by Hilbert transform of the decomposed modal responses and the change in the output covariance. Finally, the validity of the proposed method paves the way for more effective output-only modal identification for assessment of existing steel-concrete buildings.

11 August 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JNJungtae Noh
Jungtae Noh
JHJaeseung Hwang
Jaeseung Hwang
This study aims to propose and validate the state space mode decomposition technique for precise mode separation of non-classical damping systems and closely distributed modal systems. To assess the reliability and applicability of this technique, a 40-story building with a tuned mass damper is investigated, and acceleration responses measured by the building’s health monitoring system are used for the verification of the technique. The mode separation results reveal that the separated modal power spectrum becomes distorted at neighboring natural frequency ranges when the performance index only considers the concentration of power spectral energy at the target natural frequency. However, by introducing an augmented performance index that includes a constraint condition to account for distortion, more accurate mode decomposition can be achieved.

9 August 2017 in ISPRS Annals of the Photogrammetry, Remote Sensing and Spatial Information Sciences
Verified
Journal Article
Open access
PDF file
JNJungtae Noh
Jungtae Noh
SRSalvatore Russo
Salvatore Russo
Keywords: Long-term Monitoring, Palazzo Ducale, Ambient Vibration, Dynamic Monitoring, Noise, double-leaf Long-term dynamic monitoring of the masonry façade of Palazzo Ducale known as Doge’s palace in Venice, Italy was performed from September 2010 to October 2012. This article demonstrates the results of preliminary analysis on the data set of the first 12-month long monitoring campaign for out-of-plumb dynamic responses of the medieval façade of the monument. The aim of the analysis of the dynamic signals is to validate the data set and investigate dynamic characteristics of the vibration signature of the historical masonry wall in the long-term. Palazzo Ducale is a heavily visited heritage due to its high cultural importance and architectural value. Nevertheless, little is known about the dynamic behaviour of the double-leaf masonry façade. In this study, the dynamic properties of the structure are presented by dynamic identification carried out with the effect of the ambient vibration measured at four different locations on the façade and portico level. The trend and intensity of the vibration at each measurement locations are identified over the year. In addition, the issue on eliminating the noise blended in the signals for reliable analysis are also discussed.

2 September 2025 in Sensors
Verified
Journal Article
Open access
PDF file
JNJungtae Noh
Jungtae Noh
JHJaeseung Hwang
Jaeseung Hwang
Maria Rosa ValluzziMaria Rosa Valluzzi
Maria Rosa Valluzzi
Vibration control systems are extensively utilized in structures to enhance their resilience against earthquakes and wind forces. However, structures with significant damping exhibit atypical damping behaviors, which impose constraints on the effectiveness of traditional modal analysis methods for discerning modal responses and estimating properties. To surmount this challenge, a novel State-Space-Based Modal Decomposition approach is proposed in this study. The State-Space-Based Modal Decomposition technique adeptly extracts modal responses and identifies modal attributes from acquired data of highly damped structures. The approach accurately calculates damping ratios and natural frequencies by scrutinizing the power spectrum within the deconstructed modal response. The validity of this method is confirmed through a numerical simulation with a three-degree-of-freedom system equipped with oil dampers and experimentation of a structure outfitted with a tuned mass damper system. The findings underscore that the transfer function of the modal response in state-space encompasses both displacement and velocity transfer functions. The results demonstrate that precise estimation of modal parameters can be accomplished by suitably evaluating the participation ratio of the two response components.

6 June 2023 in Preprints.org
Verified
Preprint
Open access
JNJungtae Noh
Jungtae Noh
JHJae-Seung Hwang
Jae-Seung Hwang
The aim of this study is to propose and validate the state space mode decomposition technique for precise mode separation of non-classical damping systems and closely distributed modal systems. To assess the reliability and applicability of this technique, a 40-story building with a tuned mass damper is investigated, and acceleration responses measured by the building's health monitoring system are used for the verification of the technique. The mode separation results reveal that the separated modal power spectrum becomes distorted at neighboring natural frequency ranges when the performance index only considers the concentration of power spectral energy at the target natural frequency. However, by introducing an augmented performance index that includes a constraint condition to account for distortion, more accurate mode decomposition can be achieved.