Xiaoou Hu

Mr. Xiaoou Hu

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
RMrui miao
rui miao
XHXiaoou Hu
Xiaoou Hu
Yao YuYao Yu
Yao Yu
Qifeng ZhangQifeng Zhang
Qifeng Zhang
Zhibin LinZhibin Lin
Zhibin Lin
AMAhmed Cherif Megri
Ahmed Cherif Megri
A thermoelectric module is a device that converts electrical energy into thermal energy through a mechanism known as the Peltier effect. A Peltier device has hot and cold sides/substrates, and heat can be pumped from the cold side to the hot side under a given voltage. By applying it in buildings and attaching it to building envelope components, such as walls, as a heating and cooling device, the heating and cooling requirements can be met by reversing the voltage applied on these two sides/substrates. In this paper, we describe a novel, panelized, ground source, radiant system design for space heating and cooling in buildings by utilizing the Peltier effect. The system is equipped with water pipes that are attached to one side of the panel and connected with a ground loop to exchange heat between the cold/hot sides of the thermoelectric module and the underground region. The ground loop is inserted in boreholes, similar to those used for a vertical closed-loop Ground Source Heat Pump (GSHP) system, which could be more than a hundred meters deep. Experiments were conducted to evaluate the feasibility of the developed panel system applied in buildings. The results show that: (1) the average cooling Coefficients Of Performance (COP) of the system are low (0.6 or less) even though the ground is used as a heat sink, and thus additional studies are needed to improve it in the future, such as to arrange the thermoelectric modules in cascade and/or develop a new thermoelectric material that has a large Seebeck coefficient; and (2) the developed system using the underground region as the heat source has the potential of meeting heating loads of a building while maintaining at a higher system coefficient of performance (up to ~3.0) for space heating, compared to conventional heating devices, such as furnaces or boilers, especially in a region with mild winters and relatively warm ground.

14 September 2022 in Science and Technology for the Built Environment
Verified
Journal Article
Closed access
Yao YuYao Yu
Yao Yu
AMAhmed C. Megri
Ahmed C. Megri
RMRui Miao
Rui Miao
XHXiaoou Hu
Xiaoou Hu
Atriums in modern building designs often represent particular problems related to energy and airflow distribution, such as thermal stratification, local overheating, and uncontrolled contaminant spreading. This study developed a new dynamic zonal model with air-diffuser (DOMA) to predict the airflow and temperature stratification of an atrium, and then it was experimentally calibrated (known as DOMA+) by using the Shuffled Complex Evolution method developed at the University of Arizona (SCE-UA). Two-parameter set groups were considered during the calibration, which are Group One, including the flow coefficient K and the convective heat transfer coefficients for surfaces of the atrium; in Group Two, the flow coefficient K is separated into K-horizontal and K-vertical representing the flow coefficient used in horizontal and vertical directions. The results show that although the Group-One calibrated zonal model with one K is accurate to predict space thermal behavior, an update to two Ks (Group Two) is suggested to improve the zonal model prediction accuracy and quality. The use of the SCE-UA model reveals the inherent limitations and characteristics of the zonal model DOMA and thus indicates how to improve the prediction ability of a zonal modeling approach to advance its development.

1 December 2022 in Journal of Cold Regions Engineering
Verified
Journal Article
Closed access
PDF file
FYFangzheng Yuan
Fangzheng Yuan
Yao YuYao Yu
Yao Yu
MYMijia Yang
Mijia Yang
RMRui Miao
Rui Miao
XHXiaoou Hu
Xiaoou Hu
Structural snow fences have been increasingly used in northern regions of the United States. They are known as a cost-effective and efficient technology to prevent snow accumulation on highways and, therefore, improve road safety. Structural snow fences, however, are used only during winter, and to add more value to the structure, an idea to install solar photovoltaics (PV) panels on structure snow fences was first proposed by the Minnesota Department of Transportation (MnDOT), who was interested in looking at the feasibility of integrating structural snow fences with PV panels, called PV snow fences (PVSF). The PVSF would be constructed by replacing the rails between the poles of the structural fences with customized PV panels that have the same dimension as the rail. This arrangement is to ensure that the original function of the snow fences, that is, eliminating blowing and drifting snow on highways, would not be affected. Considering different factors or parameters, such as project size, panel size, installation angle or orientation of the panels, discount rate, energy selling price to a utility company, availability of incentives, ownership of the PV system, etc., a comprehensive cost–benefit model has been established to analyze the pros and cons of different implementation plans. The analysis results show that the longer the length of the PVSF is, the more cost-effective the project is, due to a lower capital cost and increased power generation. A Power Purchase Agreement (PPA) would significantly shorten the payback period in consideration of the key benefits brought through a PPA, including minimal up-front capital costs, lower energy costs, no risk, no upkeep, leveraging available tax credits, and enhancing the value of the property, which is, therefore, more realistic and would be a higher priority for an agency like MnDOT or other state DOTs.

13 January 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
NBNamrata Bista
Namrata Bista
FYFangzheng Yuan
Fangzheng Yuan
Yao YuYao Yu
Yao Yu
RMrui miao
rui miao
XHXiaoou Hu
Xiaoou Hu
MYMijia Yang
Mijia Yang
Structural snow fences are known as a cost-effective way to enhance road safety on highways, which, however, are only used during winter, making them “useless” during summer. To increase their cost-effectiveness, Photovoltaics Snow Fences (PVSF) were developed by integrating PV panels with conventional structural snow fences. As part of the feasibility study supported by the Minnesota Department of Transportation (MnDOT), a financial analysis was performed involving many parameters, such as the capital and operating costs of the PVSF system, installation orientation of the panels, discount rates, energy selling prices, availability of incentives, ownership of the PV system, etc. The effects of these parameters on the analysis results were evaluated, where critical (most sensitive) parameters were first identified, and then their quantitative effects on the analysis results were evaluated in terms of Net Present Value (NPV) and Internal Rate of Return (IRR). The results indicate that the real discount rate is the most sensitive parameter in determining the cost-effectiveness of a PVSF project in Minnesota by looking at its NPV, when the benefits, such as Federal Tax Credits, Renewable Energy Certificates, and those associated with the use of snow fences, are considered in the financial analysis. The cost of the PVSF system is the most sensitive parameter for IRR, depending on the ownership of the PV system (by MnDOT or via a Power Purchase Agreement).