Liliia Usoltseva

Mrs. Liliia Usoltseva

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2020 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
LULiliia Usoltseva
Liliia Usoltseva
MKMikhail Korobov
Mikhail Korobov
MPMikhail Proskurnin
Mikhail Proskurnin
In recent years, the demand for more efficient cooling circuits has resulted in active studies of nanofluids, two-component liquids consisting of a base fluid, and dispersed nanoparticles with high thermal conductivity. From the viewpoint of both physics and chemistry, nanofluids are systems that require the characterization of many interconnected thermal and chemical properties. This perspective article sums up the state of the art and recent trends in the development and applications of nanofluids and especially carbon nanofluids. A focus of the paper is the possibilities of photothermal and photoacoustic methods—as techniques combining molecular spectroscopy and thermal characterization—for the assessment of thermal conductivity and thermal diffusivity of nanofluids. The possibilities of photothermal spectroscopy for wider characterization of nanofluids and related materials are discussed and compared with other techniques. As nanofluids are one of the examples of complex objects dedicated to photothermal spectroscopy, more general outlooks of phototermics are also discussed.

1 December 2018 in Photoacoustics
Verified
Journal Article
Open access
LULiliia Usoltseva
Liliia Usoltseva
DVDmitry Volkov
Dmitry Volkov
DND.A. Nedosekin
D.A. Nedosekin
MKM.V. Korobov
M.V. Korobov
MPMikhail Proskurnin
Mikhail Proskurnin
VZV.P. Zharov
V.P. Zharov
The multispectral modality and technique for optically dense samples of optoacoustic spectroscopy were applied to measure spectra and high absorbances of concentrated aqueous dispersions of undoped nanodiamonds. The data from optoacoustic and optical transmission measurements and DSC data of the mean particle size by the Gibbs-Kelvin equation are compared to estimate the difference in composition of various nanodiamond trademarks. Optoacoustic spectra confirm the contribution of surface dimer chains into the absorption of nanodiamonds in the long wavelength range. Optoacoustic and conventional absorption spectra of aqueous solutions of nanodiamond fractions after centrifugation (15300g) and ultracentrifugation (130000g) revealed a separation of a highly absorbing non-diamond sp2 phase. The two-step separation by ultracentrifugation followed by extra centrifugation made it possible to isolate a highly absorbing and soluble nanodiamond phase with the particle size of 3.6 nm, showing a change in spectra compared to the starting nanodiamond material.

1 May 2021 in Ultrasonics Sonochemistry
Verified
Journal Article
Open access
IMIvan Mikheev
Ivan Mikheev
MPMariya O. Pirogova
Mariya O. Pirogova
LULiliia Usoltseva
Liliia Usoltseva
AUAnna S. Uzhel
Anna S. Uzhel
TBTimofey Bolotnik
Timofey Bolotnik
MPMikhail Proskurnin
Mikhail Proskurnin
A green, scalable, and sustainable approach to prepare aqueous fullerene dispersions (AFD) C60, C70, endohedral metallofullerene Gd@C82, and their derivatives C60Cl6, C70Cl10, and supramolecular and ester-like derivatives, 10 fullerene species total, is proposed. For the first time, an immersed ultrasonic probe was used to preparing dispersions for pristine fullerenes without addends. Both ultrasound-assisted solvent-exchange and direct sonication techniques for AFD preparation using an immersed probe were tested. The average time for AFD preparation decreases 10-15 times compared to an ultrasound-bath-assisted technique, while final fullerene concentrations in AFDs remained at tens of ppm (up to 80 ppm). The aqueous dispersions showed long-term stability, a negatively charged surface with a zeta potential up to -32 mV with an average nanocluster diameter of no more than 180 nm. The total anionic and cationic compositions of samples were found by inductively coupled plasma atomic emission spectroscopy and chromatographic techniques. The highlights and challenges of using an ultrasound probe for AFD production are discussed.

9 March 2023 in Physchem
Verified
Journal Article
Open access
PDF file
VKVladislav Khabibullin
Vladislav Khabibullin
LULiliia Usoltseva
Liliia Usoltseva
PGPolina A. Galkina
Polina A. Galkina
VGViktoriya R. Galimova
Viktoriya R. Galimova
DVDmitry Volkov
Dmitry Volkov
MPMikhail Proskurnin
Mikhail Proskurnin
A simultaneous steady-state and transient photothermal-lens modality was used for both the thermal and optical parameters of aqueous dispersed systems (carbon and silica nanoparticles, metal iodides, surfactants, heme proteins, albumin, and their complexes). Heat-transfer parameters (thermal diffusivity and thermal effusivity), the temperature gradient of the refractive index, light absorption, and concentration parameters were assessed. To simultaneously measure thermal and optical parameters, the time scale of thermal lensing (characteristic time, tc) should correspond to an excitation beam size of 60–300 µm, and the relative time intervals 0.5÷5tc and (5÷20)tc should be selected for transient and steady-state measurements, respectively. Dual-beam thermal-lens spectrometers in a mode-mismatched optical schematic at various excitation wavelengths were built. The spectrometers implement back-synchronized detection, providing different measurement conditions for the heating and cooling parts of the thermal-lens cycle. By varying the measurement parameters depending on the dispersed system, the conditions providing the suitable precision (replicability, repeatability, and reproducibility) of thermal-lens measurements were found; setups with a broad excitation beam (waist size, 150 and 300 μm) provide longer times to attain a thermal equilibrium and, thus, the better precision of measurements of thermal diffusivity.

Verified
Journal Article
Open access
PDF file
LULiliia Usoltseva
Liliia Usoltseva
VIVitaliy Ioutsi
Vitaliy Ioutsi
YPYuriy Panov
Yuriy Panov
MAMariya Antsupova
Mariya Antsupova
LRLiudmila Rozhinskaya
Liudmila Rozhinskaya
NMNatalia G. Mokrysheva
Natalia G. Mokrysheva
In current clinical practice, a thorough understanding of vitamin D metabolism is in high demand both for patients with various diseases and for healthy individuals. Analytical techniques that provide simultaneous measurement of multiple metabolites are preferred. Herein, the development of an HPLC-DMS-MS/MS method for the quantitation of vitamin D compounds (25(OH)D3, 25(OH)D2, 1,25(OH)2D3, 3-epi-25(OH)D3, 24,25(OH)2D3, and D3) in serum is described. The selected sample preparation procedure based on the combination of liquid–liquid and solid-phase extraction, which excluded a lengthy derivatization step, was compared with other common approaches. Sensitivity was increased through the implementation of differential ion mobility separation. The proposed assay allowed us to determine the low abundant 1,25(OH)2D3 with the detection limit of 10 pg/mL. The validation study showed good linearity (r2 > 0.99), a wide analytical range (2.5–75 ng/mL for 25(OH)D3), and acceptable precision (<7%) for all metabolites. The recovery ranged from 71% to 93% and the matrix effect from 0.80 to 0.95 depending on the metabolite; accuracy determination was performed using DEQAS controls.

10 March 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
VKVladislav Khabibullin
Vladislav Khabibullin
LULiliia Usoltseva
Liliia Usoltseva
IMIvan Mikheev
Ivan Mikheev
MPMikhail Proskurnin
Mikhail Proskurnin
The growing interest in heat-conducting nanofluids requires highly sensitive methods for analyzing the thermal properties. Thermal lens spectrometry (TLS), despite its advantages over classical methods, does not have a general approach for measuring and interpreting results for dispersed systems. In this paper, for nanofluids of silicon oxide in water in a wide range of concentrations and sizes, the selection of measurement parameters for transient and steady-state thermal lensing is justified, and the interpretation of the results of thermal diffusivity measurements is substantiated. The features of the measurements of thermal diffusivity by TLS under stationary states for dispersed systems are considered. Using this approach, it is possible to detect and distinguish thermal effects with high accuracy. For dispersions of silicon oxide, with increasing concentrations, the thermal diffusivity passes through a minimum threshold. Silicon oxide dispersions can be used both as coolants or as heat-removing liquids by selecting the particle size and concentration.