Vladislav Khabibullin

Mr. Vladislav Khabibullin

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
VKVladislav Khabibullin
Vladislav Khabibullin
MCMargarita Chetyrkina
Margarita Chetyrkina
SOSergei Ivanovich Obydennyi
Sergei Ivanovich Obydennyi
SMSergey Maskimov
Sergey Maskimov
GSGennady V. Stepanov
Gennady V. Stepanov
SSSergei N. Shtykov
Sergei N. Shtykov
Nanoplatforms applied for the loading of anticancer drugs is a cutting-edge approach for drug delivery to tumors and reduction of toxic effects on healthy cells. In this study, we describe the synthesis and compare the sorption properties of four types of potential doxorubicin-carriers, in which iron oxide nanoparticles (IONs) are functionalized with cationic (polyethylenimine, PEI), anionic (polystyrenesulfonate, PSS), and nonionic (dextran) polymers, as well as with porous carbon. The IONs are thoroughly characterized by X-ray diffraction, IR spectroscopy, high resolution TEM (HRTEM), SEM, magnetic susceptibility, and the zeta-potential measurements in the pH range of 3–10. The degree of doxorubicin loading at pH 7.4, as well as the degree of desorption at pH 5.0, distinctive to cancerous tumor environment, are measured. Particles modified with PEI were shown to exhibit the highest loading capacity, while the greatest release at pH 5 (up to 30%) occurs from the surface of magnetite decorated with PSS. Such a slow release of the drug would imply a prolonged tumor-inhibiting action on the affected tissue or organ. Assessment of the toxicity (using Neuro2A cell line) for PEI- and PSS-modified IONs showed no negative effect. In conclusion, the preliminary evaluation of the effects of IONs coated with PSS and PEI on the rate of blood clotting was carried out. The results obtained can be taken into account when developing new drug delivery platforms.

18 September 2024 in Molecules
Verified
Journal Article
Open access
PDF file
IPIuliia Poimenova
Iuliia Poimenova
MSMadina Sozarukova
Madina Sozarukova
DRDaria-Maria Vadimovna Ratova
Daria-Maria Vadimovna Ratova
VNVita Nikitina
Vita Nikitina
VKVladislav Khabibullin
Vladislav Khabibullin
MPMikhail Proskurnin
Mikhail Proskurnin
Redox metabolism is an integral part of the glutathione system, encompassing reduced and oxidized glutathione, hydrogen peroxide, and associated enzymes. This core process orchestrates a network of thiol antioxidants like thioredoxins and peroxiredoxins, alongside critical thiol-containing proteins such as mercaptoalbumin. Modifications to thiol-containing proteins, including oxidation and glutathionylation, regulate cellular signaling influencing gene activities in inflammation and carcinogenesis. Analyzing thiol antioxidants, especially glutathione, in biological fluids offers insights into pathological conditions. This review discusses the analytical methods for biothiol determination, mainly in blood plasma. The study includes all key methodological aspects of spectroscopy, chromatography, electrochemistry, and mass spectrometry, highlighting their principles, benefits, limitations, and recent advancements that were not included in previously published reviews. Sample preparation and factors affecting thiol antioxidant measurements are discussed. The review reveals that the choice of analytical procedures should be based on the specific requirements of the research. Spectrophotometric methods are simple and cost-effective but may need more specificity. Chromatographic techniques have excellent separation capabilities but require longer analysis times. Electrochemical methods enable real-time monitoring but have disadvantages such as interference. Mass spectrometry-based approaches have high sensitivity and selectivity but require sophisticated instrumentation. Combining multiple techniques can provide comprehensive information on thiol antioxidant levels in biological fluids, enabling clearer insights into their roles in health and disease. This review covers the time span from 2010 to mid-2024, and the data were obtained from the SciFinder® (ACS), Google Scholar (Google), PubMed®, and ScienceDirect (Scopus) databases through a combination search approach using keywords.

20 January 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
VKVladislav Khabibullin
Vladislav Khabibullin
MFMladen Franko
Mladen Franko
MPMikhail Proskurnin
Mikhail Proskurnin
Thermal-lens spectrometry is a sensitive technique for determination of physicochemical properties and thermophysical parameters of various materials including heterogeneous systems and nanoparticles. In this paper, we consider the issues of the correctness (trueness) of measurements of the characteristic time of the thermal-lens effect and, thus, of the thermal diffusivity determined by dual-beam mode-mismatching thermal lensing. As sources of systematic errors, major factors—radiation sources, sample-cell and detector parameters, and general measurement parameters—are considered using several configurations of the thermal-lens setups, and their contributions are quantified or estimated. Furthermore, with aqueous ferroin and Sudan I in ethanol as inert colorants, the effects of the intermolecular distance of the absorbing substance on the correctness of finding the thermophysical parameters are considered. The recommendations for checking the operation of the thermal-lens setup to ensure the maximum accuracy are given. The results obtained help reducing the impact of each investigated factor on the value of systematic error and correctly measure the thermophysical parameters using thermal-lens spectrometry.

9 March 2023 in Physchem
Verified
Journal Article
Open access
PDF file
VKVladislav Khabibullin
Vladislav Khabibullin
LULiliia Usoltseva
Liliia Usoltseva
PGPolina A. Galkina
Polina A. Galkina
VGViktoriya R. Galimova
Viktoriya R. Galimova
DVDmitry Volkov
Dmitry Volkov
MPMikhail Proskurnin
Mikhail Proskurnin
A simultaneous steady-state and transient photothermal-lens modality was used for both the thermal and optical parameters of aqueous dispersed systems (carbon and silica nanoparticles, metal iodides, surfactants, heme proteins, albumin, and their complexes). Heat-transfer parameters (thermal diffusivity and thermal effusivity), the temperature gradient of the refractive index, light absorption, and concentration parameters were assessed. To simultaneously measure thermal and optical parameters, the time scale of thermal lensing (characteristic time, tc) should correspond to an excitation beam size of 60–300 µm, and the relative time intervals 0.5÷5tc and (5÷20)tc should be selected for transient and steady-state measurements, respectively. Dual-beam thermal-lens spectrometers in a mode-mismatched optical schematic at various excitation wavelengths were built. The spectrometers implement back-synchronized detection, providing different measurement conditions for the heating and cooling parts of the thermal-lens cycle. By varying the measurement parameters depending on the dispersed system, the conditions providing the suitable precision (replicability, repeatability, and reproducibility) of thermal-lens measurements were found; setups with a broad excitation beam (waist size, 150 and 300 μm) provide longer times to attain a thermal equilibrium and, thus, the better precision of measurements of thermal diffusivity.

10 March 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
VKVladislav Khabibullin
Vladislav Khabibullin
LULiliia Usoltseva
Liliia Usoltseva
IMIvan Mikheev
Ivan Mikheev
MPMikhail Proskurnin
Mikhail Proskurnin
The growing interest in heat-conducting nanofluids requires highly sensitive methods for analyzing the thermal properties. Thermal lens spectrometry (TLS), despite its advantages over classical methods, does not have a general approach for measuring and interpreting results for dispersed systems. In this paper, for nanofluids of silicon oxide in water in a wide range of concentrations and sizes, the selection of measurement parameters for transient and steady-state thermal lensing is justified, and the interpretation of the results of thermal diffusivity measurements is substantiated. The features of the measurements of thermal diffusivity by TLS under stationary states for dispersed systems are considered. Using this approach, it is possible to detect and distinguish thermal effects with high accuracy. For dispersions of silicon oxide, with increasing concentrations, the thermal diffusivity passes through a minimum threshold. Silicon oxide dispersions can be used both as coolants or as heat-removing liquids by selecting the particle size and concentration.

1 October 2024 in Nanomaterials
Verified
Journal Article
Open access
PDF file
VKVladislav Khabibullin
Vladislav Khabibullin
IMIvan Mikheev
Ivan Mikheev
MPMikhail Proskurnin
Mikhail Proskurnin
Thermal lens spectrometry is a high-sensitivity method for measuring the optical and thermal parameters of samples of different nature. To obtain both thermal diffusivity and absorbance-based signal measurements with high accuracy and precision, it is necessary to pay attention to the factors that influence the trueness of photothermal measurements. In this study, the features of liquid objects are studied, and the influence of optical and thermal effects accompanying photothermal phenomena are investigated. Thermal lens analysis of dispersed solutions and systems with photoinduced activity is associated with a large number of side effects, the impact of which on trueness is not always possible to determine. It is necessary to take into account the physicochemical properties and optical and morphological features of the nanophase and components exhibiting photoinduced activity. The results obtained make it possible to reduce systematic and random errors in determining the thermal-diffusivity-based and absorbance-based photothermal signals for liquid objects, and also contribute to a deeper understanding of the physicochemical processes in the sample.