Mauro Overend

Dr. Mauro Overend


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 September 2019 in Science
Verified
Journal Article
Closed access
PDF file
Zongyin YangZongyin Yang
Zongyin Yang
TATom Albrow-Owen
Tom Albrow-Owen
HCHanxiao Cui
Hanxiao Cui
JAJack Alexander-Webber
Jack Alexander-Webber
FGFuxing Gu
Fuxing Gu
THTawfique Hasan
Tawfique Hasan
Miniaturizing spectrometers: Spectroscopy is a ubiquitous characterization tool spanning most scientific and many industrial disciplines. Most handheld spectrometers are based on tabletop optical components, which limits the scale to which these spectrometers can be shrunk. To address the desire for miniaturized spectrometers with a micrometer-scale (and smaller) footprint, Yang et al. developed such a microspectrometer based on single, compositionally engineered nanowire. This result is a practical step forward for the use of other light-sensitive nanomaterials for such ultra-miniaturized spectroscopy platforms. Science , this issue p. 1017

1 September 2019 in Energy and Buildings
Verified
Journal Article
Closed access
HCHanxiao Cui
Hanxiao Cui
MOMauro Overend
Mauro Overend

13 July 2023 in Energies
Verified
Journal Article
Open access
PDF file
MMMichalis Michael
Michalis Michael
FFFabio Favoino
Fabio Favoino
QJQian Jin
Qian Jin
ALAlessandra Luna-Navarro
Alessandra Luna-Navarro
MOMauro Overend
Mauro Overend
High-performance glazing technologies are essential for achieving the occupant comfort and building energy efficiency required in contemporary and future buildings. In real-world applications, glazing façades are selected from a steadily increasing number of glazing technologies. However, the authors could not identify a systematic and comprehensive review and classification of glazing technologies in the literature. This creates a barrier when comparing typologically different glazing technologies and combining multiple technologies in a glazing unit. This paper provides a systematic review and classification of established and emerging glazing technologies based on publications from 2001–2022 which were interpreted following the PRISMA methodology. This study reveals that the majority of high-performance glazing systems used in practice are in multi-layer glazing configurations and that the glazing system performance can focus on including additional and multiple functionalities, which aim at improving overall building performance. It was also found that there is a large potential for improvement of multilayer, evacuated, aerogels, electrochromic, and solar cell glazing by incorporating other technologies or innovative materials in multi-layer glazing units for either improving existing technologies or for the development of new ones. However, their longevity, robustness, and cost affordability should be ensured.

20 March 2023 in Glass Structures & Engineering
Verified
Journal Article
Open access
PDF file
Markus FeldmannMarkus Feldmann
Markus Feldmann
MLMaximilian Laurs
Maximilian Laurs
JBJan Belis
Jan Belis
NBNebojsa Buljan
Nebojsa Buljan
ACAnnie Criaud
Annie Criaud
ASAnna Sikynova
Anna Sikynova
Since the beginning of 2021, CEN/TS 19100 Design of Glass Structures has been available in its first three parts. The fourth part is expected soon. This Technical Specification of the European standards organisation CEN is as a pre-standard of a corresponding future Eurocode. These documents constitute the first ever comprehensive design code for the entire structural glass engineering field on the European market for the first time. In addition to a clear outline, the Technical Specification has been drafted to be compatible with EN 1990 “Basis of Design” and to address glass-specific design matters, particularly related to robustness and redundancy. Although the standard still has the status of a CEN/TS, thereby allowing the European nations the option of whether to introduce it, either in full or in parts, it already contains national openings through which the European countries can adapt the design results to their own safety level by National Determined Parameters (NDPs). Such an approach already anticipates the future Eurocode, which is expected to be published as EN 19100—Design of Glass Structures. This article provides some context on the history and concept behind the new documents and gives an overview of the design rules and the corresponding technical background of the different parts of CEN/TS 19100.

26 September 2022 in Glass Structures & Engineering
Verified
Journal Article
Open access
PDF file
RHRebecca Hartwell
Rebecca Hartwell
GCGraham Coult
Graham Coult
MOMauro Overend
Mauro Overend
Glass is one of the UK’s eight energy-intensive industries. As such, it is under scrutiny to decouple growth in production from greenhouse gas (GHG) emissions. Recycled glass, also known as cullet, requires less energy to melt than primary raw materials in new glass production. The use of cullet thus reduces the energy intensity per unit of output whilst also reducing demand for primary material resources. However, efficient systems for flat glass collection are yet to be established in the UK, resulting in a limited supply of cullet available for the flat glass market and missed environmental opportunities. This study identifies the existing supply-chain inefficiencies in the UK glass industry in three stages. Firstly, the mass flows of materials within the three main glass sectors: container glass, flat glass and glass wool, are mapped from natural resource through to primary application and subsequent end-of-life management based on a reference year of annual production figures. The map is presented in the form of a “Sankey” diagram which draws attention to several opportunities for increasing resource efficiency; namely in the stark contrast in glass collection rates between the flat and container glass industry. Using the data collected on the annual mass flows of materials in the UK flat glass sub-sector, the energy (MJ) and GHG emission (CO2-eq) saving potential of enhanced end-of-life collection methods are assessed, based on three alternative recovery scenarios. These scenarios consider the use of alternative distributions of recovered flat glass cullet in the three primary glass sub-sectors. The emission savings resulting from each recovery scenario are evaluated, based on the estimated tonnage yield of finished flat glass products. It is shown that together with improved manufacturing yield, the reutilization of end-of-life flat glass as cullet in new production could reduce the annual emissions of the UK flat glass value-chain by up to 18.6%. Finally we review the existing barriers to recycling different glass types based on acceptability criteria and available take-back infrastructure, and thus find that the advancement of improved recycling rates will rely on establishing the business opportunity and/or supporting policy for developing efficient systems for flat glass collection.

1 December 2013 in Engineering Structures
Verified
Journal Article
Closed access
JWJames Watson
James Watson
JNJens Nielsen
Jens Nielsen
MOMauro Overend
Mauro Overend