Michalis Michael

Dr. Michalis Michael

Engineering Department, University of Cambridge, Cambridge, Cambridgeshire, UK
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2023 in Energies
Verified
Journal Article
Open access
PDF file
MMMichalis Michael
Michalis Michael
FFFabio Favoino
Fabio Favoino
QJQian Jin
Qian Jin
ALAlessandra Luna-Navarro
Alessandra Luna-Navarro
MOMauro Overend
Mauro Overend
High-performance glazing technologies are essential for achieving the occupant comfort and building energy efficiency required in contemporary and future buildings. In real-world applications, glazing façades are selected from a steadily increasing number of glazing technologies. However, the authors could not identify a systematic and comprehensive review and classification of glazing technologies in the literature. This creates a barrier when comparing typologically different glazing technologies and combining multiple technologies in a glazing unit. This paper provides a systematic review and classification of established and emerging glazing technologies based on publications from 2001–2022 which were interpreted following the PRISMA methodology. This study reveals that the majority of high-performance glazing systems used in practice are in multi-layer glazing configurations and that the glazing system performance can focus on including additional and multiple functionalities, which aim at improving overall building performance. It was also found that there is a large potential for improvement of multilayer, evacuated, aerogels, electrochromic, and solar cell glazing by incorporating other technologies or innovative materials in multi-layer glazing units for either improving existing technologies or for the development of new ones. However, their longevity, robustness, and cost affordability should be ensured.

14 January 2022
Verified
Book Chapter
Closed access
FFFabio Favoino
Fabio Favoino
RLRoel C.G.M. Loonen
Roel C.G.M. Loonen
MMMichalis Michael
Michalis Michael
GMGiuseppe De Michele
Giuseppe De Michele
SAStefano Avesani
Stefano Avesani

1 November 2021 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
MMMichalis Michael
Michalis Michael
MOM Overend
M Overend
Glazing is a critical buildings element as it is the most vulnerable envelope part to heat gain and heat loss accounting for around 50% of a building’s energy consumption. However, conventional glazing technologies have relatively low-performance characteristics which cause significant heat losses during winter and undesired heat gain in summer. In this regard, this study investigates the thermal and visual performance of various design configurations of a novel glazing technology, named Closed Cavity Façade (CCF), in comparison with traditional glazing technologies. Several CCF configurations were examined using Energy Plus and IDA ICE and compared to the baseline Double Glazing Unit (DGU) (traditional or thermochromic). MATELab, an office-like test facility at the University of Cambridge was used as the model for the simulations, which was beforehand experimentally validated. The results showed extensive benefits of CCFs compared to DGU systems, in terms of thermal performance and comfort. A 22-41% or 21-37% decrease in annual total energy consumption, compared to traditional DGU or thermochromic respectively, are identified along with a positive effect on thermal comfort with a significant reduction in radiant discomfort. Further investigation showed that glass coatings and solar shading device’s characteristics play an important role in achieving further performance improvements.

20 September 2022 in Journal of Facade Design and Engineering
Verified
Journal Article
Open access
PDF file
EBEsther Borkowski
Esther Borkowski
ALAlessandra Luna-Navarro
Alessandra Luna-Navarro
MMMichalis Michael
Michalis Michael
MOMauro Overend
Mauro Overend
DRDimitrios Rovas
Dimitrios Rovas
RRRokia Raslan
Rokia Raslan
The thermal performance of adaptive building envelopes can be evaluated using building performance simulation tools. Simulation capabilities and accuracy in predicting the dynamic behaviour of adaptive building envelopes can be enhanced through co-simulation. However, it is unclear how accurately co-simulation can predict the performance of adaptive building envelopes and how the accuracy of adaptive building envelope models created in co-simulation setups can be assessed and validated. Therefore, this study presents new evidence on the empirical validation of co-simulation setups for adaptive building envelopes by establishing an assessment framework to determine the extent to which they can accurately represent the real world. The framework was applied to a case study to validate a co-simulation setup for a blind automation system using monitored data from MATELab, a full-scale outdoor test facility with realistic indoor and outdoor conditions. The validation of the co-simulation model of MATELab resulted in a median CV-RMSE index, a measure of model accuracy, of 5.9%. This indicates that the simulated data points have a small variance relative to the measured data points, showing a good model fit. In the future, modellers from the façade community can use the assessment framework for their co-simulation setups.