Intramyocardialhemorrhage (IMH) reflects severe reperfusion injury in acute myocardial infarction. Non-invasive detection of IMH by cardiovascular magnetic resonance (CMR) may serve as a surrogate marker to evaluate the effect of preventive measures to reduce reperfusion injury and hence provide additional prognostic information. We sought to investigate whether IMH could be detected by CMR exploiting the T1 shortening effect of methemoglobin in an experimental model of acute myocardial infarction. The results were compared to T2-weighthed short tau inversion recovery (T2-STIR), and T2*-weighted(T2*W) sequences.
1 August 2019 in Journal of Magnetic Resonance Imaging
Hyperpolarised MRI with Dynamic Nuclear Polarisation overcomes the fundamental thermodynamic limitations of conventional magnetic resonance, and is translating to human studies with several early-phase clinical trials in progress including early reports that demonstrate the utility of the technique to observe lactate production in human brain cancer patients. Owing to the fundamental coupling of metabolism and tissue function, metabolic neuroimaging with hyperpolarised [1-13C]pyruvate has the potential to be revolutionary in numerous neurological disorders (e.g. brain tumour, ischemic stroke, and multiple sclerosis). Through the use of [1-13C]pyruvate and ethyl-[1-13C]pyruvate in naïve brain, a rodent model of metastasis to the brain, or porcine brain subjected to mannitol osmotic shock, we show that pyruvate transport across the blood-brain barrier of anaesthetised animals is rate-limiting. We show through use of a well-characterised rat model of brain metastasis that the appearance of hyperpolarized [1-13C]lactate production corresponds to the point of blood-brain barrier breakdown in the disease. With the more lipophilic ethyl-[1-13C]pyruvate, we observe pyruvate production endogenously throughout the entire brain and lactate production only in the region of disease. In thein vivoporcine brain we show that mannitol shock permeabilises the blood-brain barrier sufficiently for a dramatic 90-fold increase in pyruvate transport and conversion to lactate in the brain, which is otherwise not resolvable. This suggests that earlier reports of whole-brain metabolism in anaesthetised animals may be confounded by partial volume effects and not informative enough for translational studies. Issues relating to pyruvate transport and partial volume effects must therefore be considered in pre-clinical studies investigating neuro-metabolism in anaesthetised animals, and we additionally note that these same techniques may provide a distinct biomarker of blood-brain barrier permeability in future studies.
Natural estrogen decline leads to vasomotor symptoms (VMS). Hormone therapy alleviates symptoms but increases cancer risk. Effective treatments against VMS with minimal cancer risks are needed. We investigate the effects of a highly bioavailable aglycone rich Red Clover isoflavone treatment to alleviate existing menopausal VMS, assessed for the first time by 24hour ambulatory skin conductance (SC) We conducted a parallel, double blind, randomised control trial of 62 peri-menopausal women aged 40–65, reporting ≥ 5 hot flushes/day and follicle stimulating hormone ≥35 IU/L. Participants received either twice daily treatment with bioavailable RC extract (RCE), providing 34 mg/d isoflavones and probiotics, or masked placebo formulation for 12 weeks. The primary outcome was change in daily hot flush frequency (HFF) from baseline to 12 weeks using 24hr SC. Secondary outcomes were change in SC determined hot flush intensity (HFI), self-reported HFF (rHFF) and hot flush severity (rHFS), blood pressure and plasma lipids. A significant decrease in 24hr HFF (P < 0.01) and HFI (P<0.05) was found when comparing change from baseline to 12 months of the RCE (-4.3 HF/24hr, CI -6.8 to -2.3; -12956 μS s-1, CI -20175 to -5737) with placebo (0.79 HF/24hr, CI -1.56 to 3.15; 515 μS s-1, CI -5465 to 6496). rHFF was also significantly reduced (P <0.05)in the RCE (-2.97 HFs/d, CI -4.77 to -1.17) group compared to placebo (0.036 HFs/d, CI -2.42 to 2.49). Other parameters were non-significant. RCE was well tolerated. Results suggest that moderate doses of RCE were more effective and superior to placebo in reducing physiological and self-reported VMS. Findings support that objective physiological symptom assessment methods should be used together with self-report measures in future studies on menopausal VMS. ClinicalTrials.gov NCT02028702
Aims: Contact force (CF) between radiofrequency (RF) ablation catheter and myocardium and ablation index (AI) correlates with RF lesion depth and width in normal-voltage (>1.5 mV) myocardium (NVM). We investigate the impact of CF on RF lesion depth and width in low (<0.5 mV) (LVM) and intermediate-voltage (0.5–1.5 mV) myocardium (IVM) following myocardial infarction. Correlation between RF lesion depth and width evaluated by native contrast magnetic resonance imaging (ncMRI) and gross anatomical evaluation was investigated.Methods and results: Twelve weeks after myocardial infarction, 10 pigs underwent electroanatomical mapping and endocardial RF ablations were deployed in NVM, IVM, and LVM myocardium. In vivo ncMRI was performed before the heart was excised and subjected to gross anatomical evaluation. Ninety (82%) RF lesions were evaluated. Radiofrequency lesion depth and width were smaller in IVM and LVM compared with NVM (P < 0.001). Radiofrequency lesion depth and width correlated with CF, AI, and impedance drop in NVM (CF and AI P < 0.001) and IVM (CF and AI depths P < 0.001; CF and AI widths P < 0.05). Native contrast magnetic resonance imaging evaluated RF lesion depth and width correlated with gross anatomical depth and width (NVM and IVM P < 0.001; LVM P < 0.05).Conclusions: Radiofrequency lesions deployed by similar duration, power and CF are smaller in IVM and LVM than in NVM. Radiofrequency lesion depth and width correlated with CF, AI, and impedance drop in NVM and IVM but not in LVM. Native contrast magnetic resonance imaging may be useful to assess RF lesion depth and width in NVM, IVM, and LVM.