Chun-Chi Wang

Dr. Chun-Chi Wang


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2016 in ChemBioChem
Verified
Journal Article
Closed access
PDF file
CWChun-Chi Wang
Chun-Chi Wang
SWShou-Mei Wu
Shou-Mei Wu
HLHung‐Wen Li
Hung‐Wen Li
Huan-Tsung ChangHuan-Tsung Chang
Huan-Tsung Chang

1 May 2020 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
CWChun-Chi Wang
Chun-Chi Wang
PHPo-Tsang Huang
Po-Tsang Huang
HKHwang- Shang Kou
Hwang- Shang Kou
SWShou-Mei Wu
Shou-Mei Wu

1 July 2017 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
SHSung-Yu Hsieh
Sung-Yu Hsieh
CWChun-Chi Wang
Chun-Chi Wang
HKHwang-Shang Kou
Hwang-Shang Kou
SWShou-Mei Wu
Shou-Mei Wu

30 September 2022 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
CCChun-Hsien Chen
Chun-Hsien Chen
YJYuh-Jyh Jong
Yuh-Jyh Jong
YCYu-Ying Chao
Yu-Ying Chao
CWChun-Chi Wang
Chun-Chi Wang
YCYen-Ling Chen
Yen-Ling Chen

11 September 2018 in Analytical Chemistry
Verified
Journal Article
Closed access
CWChun-Chi Wang
Chun-Chi Wang
CCChung-An Chen
Chung-An Chen
YJYuh-Jyh Jong
Yuh-Jyh Jong
HKHwang-Shang Kou
Hwang-Shang Kou

1 January 2020 in Journal of Food and Drug Analysis
Verified
Journal Article
Open access
KLKung-Hung Lin
Kung-Hung Lin
HKHwang-Shang Kou
Hwang-Shang Kou
YLYi-Hui Lin
Yi-Hui Lin
CWChun-Chi Wang
Chun-Chi Wang
Hyaluronic acid (HA), a multi-functional material, has a high dispersion in molecular weight, and the functions of HA are determined through the size. Nevertheless, hyaluronic acid mixtures are not easily separated due to their polydispersity. In this study, a capillary electrophoresis strategy was developed for resolution of different molecular-weight HA without enzymatic digestion. Here, hyaluronic acid mixtures with low molecular weight (380 kD; LHA) and high molecular weight (2180 kD; HHA) were successfully resolved by the SDS integrated with low molecular-weight polymer in capillary electrophoresis. By optimizing experimental conditions, the separation of LHA and HHA was completed within 14 min. The optimal conditions were as follows: the running buffer was 25 mM borate buffer (pH 9.75) containing 30 mM SDS and 10% polyethylene glycol (MW: 8000); applied voltage was 20 kV (detector at cathode side) and separation temperature was set at 25 °C. The data of method validation showed that calibration plots were linear (r ≥ 0.9977) over a range of 10-50 μg/mL for LHA, and 40-200 μg/mL for HHA. In the evaluation of precision and accuracy for this method, the RSD and RE values were all less than 4.2%. This fascinating technique was successfully applied to the quality control of cosmetic and pharmaceutical containing different ratios of LHA and HHA, and it was feasible for serving as a tool to quantitatively analyze different sizes of HA for clinical survey.