Affected by the nonlinear time-varying factors due to fault scenarios, protection relaying, and control measures, the dynamic behaviors of a power system may be significantly different from the results of previous methods. In order to analyze the oscillation characteristics of complex power systems more accurately and suppress the low frequency oscillation more effectively, this paper improves the trajectory section eigenvalue method. Firstly, the time response of a system is obtained by numerical simulation in a given fault scenario. Secondly, the algebraic variables are substituted to the differential equations along the trajectory. Thus, the original time-varying differential-algebraic equations are approximated by a set of linear ordinary differential equations, which can be updated along the trajectory. On this basis, this paper proposes a method to extract instantaneous features of the oscillation from the micro perspective. The non-equilibrium points with strong nonlinearity or critical eigenmodes are identified by the proposed method. The simulation test results of the IEEE 3-machine 9-bus system and the New England system illustrate the validity of the proposed method.
With the development of the new power system with a high proportion of new energy and a high proportion of power electronic equipment, various problems caused by high-frequency oscillation will seriously affect the daily normal operation of the power system. For the existing active oscillatory suppression strategies, the impedance characteristics of other frequency bands will be affected, which may cause new oscillation problems in other frequency bands, namely the negative effect of oscillatory suppression strategy. In response to such phenomena, we conducted research on the mechanism of negative effects and optimize the control strategies accordingly. First, an analysis model of the grid-connected inverter was established. The concept of the damping factor was proposed based on the relationship between passive damping and active damping. The feasibility of the oscillation suppression mechanism based on the damping factor was demonstrated, and the negative effect mechanism of the oscillation suppression strategy was clarified. Secondly, a control strategy based on the superposition of active damping was proposed, which not only solved the negative effect of the oscillation suppression strategy but also avoided the shift of the inherent resonance point. Finally, the theory was verified based on the MATLAB R2022a/Simulink simulation platform.
Changes in modal order alter the predictor dimension, pole-label swaps disrupt frequency continuity, and time-varying envelopes affect phasor magnitude and phase. Estimating these quantities independently can propagate errors across successive processing stages. A coordinated estimator is developed for the modal subspace, pole states, and regression parameters. An order confidence index combines the spectral gap, cumulative energy, and noise separation to select the model order and reconstruct the signal in one low-rank subspace. Variable-order recursive prediction and frequency–damping state association then form continuous pole trajectories, followed by adaptive smoothing and class-dependent unit-circle projection. The associated oscillatory and decaying direct-current (DC) poles update the Maclaurin regression atoms. Finite-window coupling is handled by either modal initialization followed by Gram iteration or a direct joint regularized solution, avoiding repeated leakage compensation. Tests with modal-order changes, frequency dynamics, modal crossings, amplitude modulation, and decaying DC show that the coordinated parameter chain preserves pole identity and improves dynamic phasor measurement. In the main dynamic test case, the mean and 95th-percentile total vector errors (TVEs) are 3.2082% and 6.0672%; the 95% paired confidence interval for the mean-TVE difference between the proposed method and estimation of signal parameters via rotational invariance techniques (ESPRIT) remains below zero. A separate RK3568 bare-metal test of the standalone three-tone Prony kernel completed 800 frames without a processing failure. Its mean processing time was 18.621 ms per frame, with observed values from 18.537 to 19.070 ms.
With the growing penetration of renewable energy, accurately characterizing the frequency support performance of grid-following wind and photovoltaic (PV) units has become increasingly important. However, conventional methods for assessing frequency support parameters often overlook practical dynamic effects, making it difficult to determine the support parameters actually realized during disturbances. To address the time-domain coupling, differential noise amplification, and parameter distortion problems in the online identification of virtual primary frequency regulation and virtual inertia coefficients, this paper establishes a frequency response model for wind and PV units that incorporates these support mechanisms together with practical physical constraints. On this basis, a two-stage forgetting-factor recursive least squares (FF-RLS) method is proposed to identify realized frequency support parameters. Exploiting the difference in response time scales between primary frequency regulation and inertial support, a quasi-steady-state frequency regulation window and a transient inertia window are constructed to decouple the two parameters. Meanwhile, Tustin phase compensation and band-limited differentiation are introduced to mitigate measurement noise and the phase mismatch between frequency and power responses. Finally, a stable window criterion is developed to adaptively extract reliable identification intervals. Simulation studies on a modified IEEE 24 bus system, together with comparisons against conventional identification methods, demonstrate the effectiveness and accuracy of the proposed method.
The offshore AC system is a passive system without any synchronous power supply. The offshore converter station provides a stable voltage and frequency source for the system. Both ends of the system are power electronic converters with different negative-sequence suppression (NSS) strategies, which significantly influence the transient response characteristics at the point of common coupling and the convergence bus of wind farms. Thus, the fault characteristics and fault ride-through characteristics of the offshore AC system are determined by the control modes and negative-sequence suppressions. A real-time-digital-simulation platform of offshore wind power integrated via VSC-HVDC system is constructed according to the actual topology and parameters of Rudong project. Based on the platform, the configuration program and control objectives of existing NSS strategies are explicated. The influences of NSS on fault characteristics and fault ride-through characteristics are revealed.