Phasor measurement units (PMUs) are one of the most effective devices for measuring power system dynamics, and it is critically important that they have good performance. This paper proposes a high-accuracy synchrophasor estimation algorithm and builds a PMU calibrator to offer reference values for PMU test and calibration in the laboratory. Based on a general signal-fitting model, a nonlinear-fitting-based phasor and frequency estimation algorithm using an iterative solution are proposed. A rate-of-change-of-frequency (ROCOF) estimation method using the filter spectrum characteristic of a least-squares method is proposed to improve ROCOF measurement accuracy under dynamic conditions. For PMU laboratory tests, an interference suppression method and a post-processing method for step tests are presented. Then, the selected hardware for the PMU calibrator is tested, and its influence on phasor measurement is analyzed. Simulations and experiments verify that the accuracy of the calibrator is at least 30 times better than the requirements in PMU compliance standards of both IEEE and China, indicating that it can be used for PMU testing and calibration. In addition, the calibrator is also verified that it can offer references with high accuracy under combined tests, since the proposed algorithm is based on one general signal-fitting model.
13 September 2021 in IEEE Transactions on Smart Grid
With the rapid development of distributed renewables, DC transmission, and active loads, increasingly more power electronics are and will be introduced into distribution grids. This has led to an increasing need for a new synchronized measurement system that covers different scenarios and applications to improve the stability and reliability of power-electronics-enabled power grids. In this paper, a full-view synchronized measurement system (SYMS) for the renewables, controls, loads, and waveforms of power-electronics-enabled power distribution grids is established, and is composed of different types of synchronized measurement devices (SMDs) and a data center. A general design method for the synchrophasor estimation of SMDs in different scenarios is proposed by deducing phasor measurement error models. This is further applied in combination with the design of hardware and a communication protocol to develop SMDs for the measurement of the renewables, controls, loads, and waveforms of power-electronics-enabled power distribution grids. Then, a framework of the data center of the SYMS, as well as several potential applications based on real-time measurements, are presented and discussed. The SYMS is a comprehensive, shared, and open power system data platform for use by future researchers.
17 November 2020 in IEEE Transactions on Power Delivery
The measurement data of P-class phasor measurement units (PMUs) is used for protection and control applications. The reporting latency is critical for these applications. However, the data window of fundamental frequency estimation is commonly longer than that of phasor estimation, which introduces additional latency. In this paper, a novel frequency estimation method that uses sampling values rather than phase angles is proposed for P-class PMUs to reduce their reporting latency. This method uses two complex bandpass filters with different gains to extract the two positive fundamental components of the power signals. A one-to-one correspondence between the frequency and the ratio of the two positive fundamental components is established. By polynomial fitting this relationship, the frequency under static and dynamic conditions can be accurately estimated. In addition, to ensure the accuracy, the two applied complex bandpass filters are designed according to standard requirements, which can effectively suppress the negative fundamental component and harmonics. The simulation and experimental test results show that the proposed method achieves a frequency measurement accuracy that is 10 times higher than the standard requirements with a low computational burden and a data window of two cycles, indicating that the proposed method is suitable for P-class PMUs.
24 August 2020 in IEEE Transactions on Circuits and Systems I: Regular Papers
Resampling technology is becoming increasingly critical, as different frequency components are required to be measured in one device. In this paper, a resampling method based on filter designed by window function is proposed to satisfy the requirements of different sampling rates. The frequency responses of the filter in the resampling model based on the Farrow structure are investigated, and the design criterion of the filter in the resampling model is proposed. A fractional delay filter design model based on window function method is established. A fractional delay filter coefficient matrix, which is expressed by a polynomial form, is constructed. Then, the expression related to the subfilter coefficients is obtained and subfilter coefficients are solved by the least-square method. The simulation results show that the filter designed by the proposed method has better performance when used for resampling as compared those designed by existing methods, and can efficiently prevent the occurrence of frequency aliasing and mirroring components in the process of sampling rate conversion. Therefore, the proposed method meets the conditions for application to existing measurement devices.
24 November 2020 in IEEE Transactions on Smart Grid
Driven by the increasing development and complexity of bulk power systems, the requirements of phasor estimation methods differ for different scenarios and applications. In this study, a general design method for phasor estimation algorithms in different applications is proposed based on a complex finite impulse response (FIR) bandpass filter. A design framework based on mathematical error models is proposed to facilitate the design of a complex bandpass filter for different requirements and to reduce the trial and error process. The general error models between the filter gain and the error limitations of all variables measured by the phasor measurement units (PMUs) are established separately, according to the absolute value inequality. The filter design criteria obtained from the error models can determine the passband and stopband gain range of the complex bandpass filters. Three phasor algorithms for different classes of PMUs are designed, and their performances are validated and compared using experimental tests. The results demonstrate that the proposed method can design phasor algorithms to provide accurate measurements under different scenarios.
DC converter stations have a high voltage level, a long transmission distance, and complex internal equipment, and contain power electronic devices, which seriously endanger the stable operation of the system itself and the active distribution network at the receiving end when faults occur. Accurate fault analysis and diagnosis are critical to the safe and stable operation of power systems. Traditional fault diagnosis methods often rely on a single source of information, leading to issues such as insufficient information utilization and incomplete diagnostic scope when applied to DC transmission systems. To address these problems, a fault diagnosis method for converter stations based on preliminary identification of the fault range and the fusion of evidence information of the switch signal and electrical quantity is proposed. First, the preprocessing of converter station sequential event recording (SER) events and a statistical analysis of event characteristics are completed to initially determine the range of the fault.Then, a fuzzy Petri net model and a BP neural network model are constructed on the basis of the fault data from a real-time digital simulation system (RTDS), and the corresponding evidence information of the switch signal and electrical quantity are obtained via iterative inference and deep learning methods. Finally, on the basis of D-S evidence theory, a comprehensive diagnosis result is obtained by fusing the switch and electric evidence information. Taking the fault data of a DC converter station as an example, the proposed method is analyzed and compared with the traditional method, which is based on single information. The results show that the proposed method can reliably and accurately identify fault points in the protected area of the converter station.