We estimated associations between ambient air pollution, home environment and asthma as well as rhinitis among adults across China. A total of 40,279 young adults from eight Chinese cities participated in a questionnaire survey (participation rate 75%). There were questions on health and home environment. Information on city level gross domestic product (GDP) per capita, ambient temperature and PM10 and NO2 were collected from registers. Two-level logistic regression models were used to study health associations. Totally 1.6% reported asthma and 6.6% reported allergic rhinitis (AR). Higher temperature was associated with more asthma but less AR. Higher GDP was associated with less asthma but more AR. Higher degree of urbanization, higher level of NO2 and living near heavily trafficked road were risk factors for asthma and AR. Participants in older buildings reported more asthma. Redecoration and buying new furniture were related to more asthma and AR (OR = 1.15-1.91). Using natural gas (OR = 1.34) and biomass (OR = 1.35) for cooking were risk factors for AR. Burning mosquito coils and incense increased the risk of asthma and AR. Cat keeping (OR = 2.88), dog keeping (OR = 2.04), cockroaches (OR = 1.54) and rats or mice (OR = 1.46) were associated with asthma. Cockroaches increased the risk of AR (OR = 1.22). Air humidifier and air cleaner were linked to asthma and AR. Frequent cleaning and exposing bedding to sunshine were protective. In conclusion, urbanization, NO2 and traffic exhaust can increase the risk of adult asthma and AR. Higher ambient temperature was related to more asthma but less AR. Indoor animals such as cats, dogs, rats/mice and presence of cockroaches were associated with asthma or AR. Indoor chemical sources such as redecoration and new furniture were other risk factors. Cooking with natural gas or biomass and burning mosquito coils and incense were associated with asthma or AR. Frequent cleaning and exposing bedding to sunshine were protective.
The main aim was to study associations between asthma, allergic rhinitis and eczema among adults across China and dampness and mold at home. Young adults (N = 40,279) in eight cities in China answered a questionnaire in 2010-2012 (response rate 75.0%). Data on asthma, allergic rhinitis, eczema and the home environment was assessed by the questionnaire. Climate data was obtained from China Meteorological Administration and the website of Weather Underground. Health associations were analyzed by two-level logistic regression models, adjusting for covariates. Totally 1.6% had asthma, 6.6% allergic rhinitis and 2.2% eczema. Mold odor was associated with asthma (OR = 1.90) and allergic rhinitis (OR = 1.25-1.44). Window pane condensation in winter was associated with asthma (OR = 1.39), allergic rhinitis (OR = 1.26-1.58) and eczema (OR = 1.36-1.77). Presence of mold spots or damp stains was related to asthma (OR = 1.58-2.49), allergic rhinitis (OR = 1.35-1.76) and eczema (OR = 1.47-1.70). Water damage was related to asthma (OR = 1.69-1.82), allergic rhinitis (OR = 1.40-1.45) and eczema (OR = 1.44-1.96). Damp bed clothing was related to asthma (OR = 1.23), allergic rhinitis (OR = 1.23) and eczema (OR = 1.35). A higher dampness score was associated with increased odds ratios for diseases. Those living in older buildings had more asthma (OR = 1.39-1.76) and allergic rhinitis (OR = 1.16-1.21). Those living in suburban or rural areas had less asthma, allergic rhinitis and eczema as compared to those living in urban areas (OR values from 0.24 to 0.66). Stronger health associations with dampness and mold were found in southern China and in newer buildings (constructed after 2005). In conclusion, dampness and mold at home can be risk factors for asthma, allergic rhinitis and eczema among adults in China. Living in older buildings can be risk factors for asthma or allergic rhinitis while living in less urbanized areas can be protective.
Associations between measured specific VOC reported to be associated with dampness and microbial growth in dwellings and asthma, lung function were investigated in 159 adults (one adult/home) from three North European cities (Reykjavik, Uppsala and Tartu). Spirometry was performed and forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1) and FEV1/FVC were measured. Among 159 participants, 58% were females, 24.5% atopics, 25.8% current smokers and 41% reported dampness or mold at home. Dimethyl disulphide (p = 0.004), ethyl isobutyrate (p = 0.021) and ethyl 2-methylbutyrate (p = 0.035) were associated with asthma. Isobutanol (p = 0.043), 3-methyl-1-butanol (p = 0.020), 2-hexanone (p = 0.033), 1-octen-3-ol (p = 0.027), 2-methyl-1-butanol (p = 0.022) and 2-ethyl-1-hexanol (p = 0.045) were associated with lower FEV1. Isobutanol (p = 0.004), 3-methyl-1-butanol (p = 0.001), 2-heptanone (p = 0.047) and 2-methyl-1-butanol (p = 0.002) were associated with lower FEV1/FVC. The association between dimethyl disulphide and asthma was more pronounced in females (p for interaction 0.099). The association between 1-butanol and lower FEV1 was more pronounced in males (p for interaction 0.046). The associations between 3-octanone (p for interaction 0.064), 2-ethyl-1-hexanol (p for interaction 0.049) and lower FEV1, and between 2-heptanone (p for interaction 0.021), 3-octanone (p for interaction 0.008) and lower FEV1/FVC were stronger in homes with dampness/mold. Factor analysis identified one VOC factor related to asthma and two VOC factors related to lower lung function. Increased air concentrations of 2-heptanone, ethyl 2-methylbutyrate and ethyl isobutyrate were related to prescence of certain mold species (Aspergillus sp., Cladosporum sp. and Penicillium sp.) or building dampness. Some VOC were associated with type of dwelling, building age and pet keeping. In conclusion, some VOC reported to be associated with dampness and microbial growth can be associated with asthma and lower lung function in adults. Associations between these VOC and respiratory illness can be stronger in homes with dampness/mold. There can be gender differences in respiratory health effects when exposed to indoor VOC.
Totally 1160 adults living in single-family houses in Sweden participated in a questionnaire survey on subjective indoor air quality (SIAQ). Inspectors investigated the dwellings and performed home measurements (mean indoor temperature 21.4 °C, mean indoor air humidity 34.2%, mean indoor air exchange rate 0.36 ac/h and mean moisture load indoor 1.7 g/m3). Totally 15.5% perceived draught, 28.0% perceived too high room temperature, 42.4% unstable room temperature, 36.8% too low room temperature, 19.6% stuffy air, 19.8% dry air and 29.9% dust or dirt. Measured room temperature was related to perception of room temperature. Higher relative air humidity was related to perceived unstable room temperature (OR = 1.70) and too low room temperature (OR = 1.96). Higher absolute air humidity was related to too high room temperature (OR = 1.21), unstable room temperature (OR = 1.34) and too low room temperature (OR = 1.35). Higher measured relative humidity, absolute air humidity and moisture load were all associated with stuffy air and unpleasant odor (OR = 1.45-1.97). Higher air exchange rate was related to less perceived unstable room temperature (OR = 0.93). Higher U value was related to draught (OR = 1.17), too low room temperature (OR = 1.09), unpleasant odor (OR = 1.12) and dust and dirt (OR = 1.07). New concrete slab foundation was related to less stuffy air (OR = 0.39) (vs. basement). Damp foundation was associated with more stuffy air (OR = 1.44) and unpleasant odor (OR = 1.61). Window pane condensation was related to stuffy air (OR = 1.88). Moldy odor reported by inspector was related to stuffy air (OR = 1.73). Observed mold in the attic was associated with more stuffy air and unpleasant odor. In conclusion, complaints of room temperature can indicate poor thermal environment. Higher air exchange rate can create a more stable thermal sensation. Excess indoor humidity, lower degree of thermal insulation, presence of window pane condensation and indoor dampness/mold can impair SIAQ. Higher ventilation and concrete slab foundation with underlying thermal insulation can improve SIAQ.