This paper presents the characteristics of underwater electrical wire explosion (UEWE) with three discharge types, namely, Type-A, Type-B, and Type-C. Experiments were carried out with copper and tungsten wires (4 cm long and 50–300 μm in diameter) driven by a microsecond time-scale pulsed current source with 500 J stored energy. A time-integrated spectrometer and a photodiode were used to measure the optical emission of UEWE. A Polyvinylidene Fluoride probe was adopted to record the pressure waveforms. Experimental results indicate that from Type-A to Type-C, more energy deposits prior to the voltage peak and the first peak power increases drastically. This variation of energy deposition influences the optical emission and shock wave generation process. Specifically, the light intensity decreases by more than 90% and the peak of continuous spectra moves from ∼400 nm to ∼700 nm. In addition, the peak pressure of the first shock wave increases from ∼2 MPa to more than 7.5 MPa.
This paper presents the design and development of a trigger with a high repetition rate, low jitter, and compact structure for the pseudospark switch (PSS), which includes an improved Marx generator based on avalanche transistors and a corona-plasma trigger unit. The generator adopted a novel 3 × 12-stage Marx circuit based on avalanche transistors in which the failure rate of transistors in the first and second stages was significantly reduced by connecting the parallel capacitors compared to the previous similar generator. The reason for the improved performance was also discussed. The main parameters of output pulses were an amplitude of −7 kV, rise time of 6 ns, jitter of 0.2 ns, and repetition rate of 2 kHz. The corona-plasma trigger unit adopted BaTiO3 ceramics with high εr as the dielectric and was arranged in the hollow cathode of the PSS. The experiments of triggering a PSS prototype were conducted. The influence of anode voltage and pressure on the trigger delay and jitter was studied, and the minimum trigger jitter achieved <1 ns. This trigger worked for 107 shots at the repetition rate of 2 kHz continuously without obvious performance degradation and any failure of the generator. The main advantage of this trigger is the simultaneous combination of the high repetition rate, low jitter, long lifetime, and great simplicity in a compact structure.
12 June 2019 in IEEE Transactions on Power Electronics
Marx bank circuits (MBCs) based on avalanche transistors are widely used to generate nanosecond pulses with high power, high repetition rate and low jitter. However, it was observed that avalanche transistors in the first and second stages of traditional M×N-stage MBCs have high failure rates. This paper proposes an auxiliary triggering topology (ATT) for improving the reliability of high power MBCs based on avalanche transistors. Operation principles of ATT and failure mechanisms of MBCs are analyzed. By adopting ATT, auxiliary triggering pulse is generated between the base and emitter of the transistor, and the switching mode is changed from “overvoltage switching-on” to “triggering switching-on”. The combined effect of overvoltage ramp and auxiliary triggering pulse significantly reduces the failure rates of easily damaged transistors. Two nanosecond pulse generators, 3×12-stage and 6×10-stage MBCs adopting ATT, are developed to verify the feasibility of the proposed configuration. The output amplitude and the rising time are 8.5 kV/6 ns and 17 kV/6 ns at the open end of coaxial cable with 75 Ω impedance, respectively. Both generators are tested continuously at 2 kHz for 60 minutes and no failure occurs, which show much better performance in repetition rate and reliability than traditional M×N-stage MBCs.
9 September 2021 in IEEE Transactions on Power Electronics
In this article, we show the feasibility of improving the performance of a high voltage and high repetition avalanche transistor pulse generator by applying a two-phase immersion cooling technique. The forced air cooling, single-phase immersion cooling, and two-phase immersion cooling techniques were applied to a 60-stage subnanosecond pulse generator. The experimental results indicate that the two-phase immersion cooling technique can effectively control the temperature rising of the avalanche transistor and, thus, reduce the time base jitter and voltage amplitude jitter. Five types of dielectric fluid with different boiling temperatures were comparatively studied. The FC-72 was finally adopted for the balanced performance on voltage amplitude and repetition rate. The two-phase immersion cooling technique could reduce the thermal resistance between the case and ambient and increase the maximum power from 330 to 876 mW. With this cooling method, the surface temperature of the transistor can be effectively controlled below 62 °C. The pulse generator could achieve outstanding performance with a voltage of 2350 V and a rise time of 180 ps. It can work stably at 200 kHz for more than 30 min, and the burst repetition rate could be 260 kHz within 1 min. This article offers new perspectives in the design of high repetitive avalanche transistorized subnanosecond generators.
An experimental study of pressure waves generated by an exploding copper wire in a water medium is performed. We examined the effects of energy deposited at different stages on the characteristics of the resulting shock waves. In the experiments, a microsecond time-scale pulsed current source was used to explode a 300-μm-diameter, 4-cm-long copper wire with initial stored energies ranging from 500 to 2700 J. Our experimental results indicated that the peak pressure (4.5–8.1 MPa) and energy (49–287 J) of the shock waves did not follow a simple relationship with any electrical parameters, such as peak voltage or deposited energy. Conversely, the impulse had a quasi-linear relationship with the parameter Π. We also found that the peak pressure was mainly influenced by the energy deposited before separation of the shock wave front and the discharge plasma channel (DPC). The decay time constant of the pressure waveform was affected by the energy injection after the separation. These phenomena clearly demonstrated that the deposited energy influenced the expansion of the DPC and affected the shock wave characteristics.
Underwater shock waves (SWs) generated by underwater electrical wire explosions (UEWEs) have been widely studied and applied. Precise measurement of this kind of SWs is important, but very difficult to accomplish due to their high peak pressure, steep rising edge and very short pulse width (on the order of tens of μs). This paper aims to analyze the signals obtained by two kinds of commercial piezoelectric pressure probes, and reconstruct the correct pressure waveform from the distorted one measured by the pressure probes. It is found that both PCB138 and Müller-plate probes can be used to measure the relative SW pressure value because of their good uniformities and linearities, but none of them can obtain precise SW waveforms. In order to approach to the real SW signal better, we propose a new multi-exponential pressure waveform model, which has considered the faster pressure decay at the early stage and the slower pressure decay in longer times. Based on this model and the energy conservation law, the pressure waveform obtained by the PCB138 probe has been reconstructed, and the reconstruction accuracy has been verified by the signals obtained by the Müller-plate probe. Reconstruction results show that the measured SW peak pressures are smaller than the real signal. The waveform reconstruction method is both reasonable and reliable.