Hybrid glass-basalt reinforced plastic (HGBFRP) pipes are attractive materials for multiple use, but their quality assessment still presents a challenge. This paper presents a new fractal-based mathematical modeling technique with high speed and accuracy to assess HGBFRP pipe quality. The fractal dimension of structural units was estimated by both cellular and point techniques. Sensitivity analysis was carried out to determine the most effective structural component contributing to the individual physico-mechanical properties, respectively. Models were built to predict tensile strength, compressive strength, and elastic modulus from the fractal dimension of microstructural photographs. The fractal dimension of glass-basalt fibers ranged from 1.655 to 1.922, and that of the epoxy matrix varied from 1.599 to 1.976. The proposed models showed good accuracy with the R2 value of 0.84, 0.93, and 0.97 for tensile strength, compressive strength, and elastic modulus, respectively. The fractal-based method can be an effective and valid quality assessment of the HGBFRP pipes, especially of rapidly assessment in harsh environments like arctic areas. This novel modeling method not only improves the knowledge of material properties, but also gives the possibility to design smart monitoring systems in real time with the purpose of on-the-fly evaluations. Further, by combining the above with the technology of IoT, it may be possible to conduct the continuous monitoring of HGBFRP pipes to maintain their structural integrity in the long term.
Building thermography is a non-destructive and effective method for diagnosing the thermal insulation of buildings with various purposes. Regardless of the specifics of conducting thermographic surveys, the obtained thermal images (thermograms) can be analyzed both qualitatively and quantitatively. The first method of analyzing thermal images is implemented using specialized software typically provided with the thermal imaging camera. The second method is carried out based on the results of thermographic surveys following the methodologies regulated by the country’s normative documents. Using the example of thermographic inspection of enclosing structures in a multi-story residential building constructed from reinforced concrete panels, a qualitative assessment of thermal images was conducted to identify potential thermal defects. Thermal bridges were detected in the area of vertical joints of panel plates, and excessive heat losses were identified in the region where the heating device niche is located.Quantitative assessment of thermal images revealed that the thermal resistance in the temperature anomaly area is nearly twice as low as the thermal resistance in the baseline section of the thermogram. One of the variations for evaluating the error of indirect measurements of relative thermal resistance is presented, taking into account the range of measuring instruments used. Verification of the thermal resistance of the enclosing structure of the external wall of the residential building was conducted to ensure compliance with sanitary and hygienic requirements. According to the results of in-situ measurements, it was determined that the temperature on the inner surface of the enclosure was lower than the specified value.
Ensuring the required microclimate parameters of a cultivation structure, including indoor air temperature, relative humidity, and soil surface temperature, plays a crucial role in obtaining a rich harvest of vegetables and fruits in the winter season. Creating favourable conditions for growing plants in the protected ground is possible only by using modern, high-tech heating systems that will compensate for heat energy losses and maintain a set temperature regime in the room. Gas-fired radiant heating is one such system. This heating method, using ceiling gas infrared emitters as heat sources, directs the required heat flux directly to the soil surface. At the same time, direct or indirect emissions of harmful substances into the environment are minimal, and due to the absence of heat losses during heat production and heat carrier transportation, this type of heating is effective from both energy-saving and economic points of view. The article investigates the influence of meteorological, aerodynamic, heat engineering, and other factors on the air temperature in a cultivation structure under gas-fired radiant heating conditions using a developed software calculation method. An analysis is performed, and explanations are given for the nature of the change in indoor air temperature depending on the changing environmental conditions—the example of the industrial greenhouse “Farmer 7.5” (Russian Federation).
This article explores the fundamental principles of the software method for calculating the gas-fired heating system of a cultivation structure, where the main source of heat is provided by ceiling-mounted gas infrared radiators. To maintain the required thermal regime within the premises, a gas air heater is utilized, designed to preheat the outdoor air to the necessary temperature before supplying it to the heated space.The calculation method is based on solving a system of interconnected equations of thermal and material balances for the cultivation structure, its enclosure, and the soil surface. Possible utilization of thermal energy from high-potential combustion products of gaseous fuel is taken into account.Using the example of the “Farmer 7.5” industrial greenhouse (Russian Federation), designed for year-round cultivation of plants in closed soil (in this case, cucumbers were the subject of study until the fruitbearing stage in the winter-spring cycle), the impacts of various factors are investigated: outside air temperature, thermal resistance of the enclosing structure on the heating system’s thermal power (in combination with the gas air heater), and variable parameters of the microclimate. The latter includes the enclosure temperature of the industrial greenhouse and the intake air temperature for general exchange ventilation needs. Specific conclusions and prospects for further scientific research are drawn based on the obtained results.
Energy conservation is a priority for most of the nation states. Its relevance in modern world energy industry is growing every year. This problem acquires particular importance when a country is characterized by a lack of fuel and energy resources or adverse climatic conditions. The most effective way to reduce heat losses from heat network pipelines to environment is the use of heat insulation. This paper presents the results of application heat-insulating paint on the surface of main pipeline. The infrared thermometry devices (pyrometer and thermal imager) were used to evaluate the energy efficiency of modern high-tech insulation. The thermograms from thermal imager and the readings from pyrometer were analyzed, it was established that the absolute difference in temperatures of an isolated pipeline section and an unpainted section are 5-10 °C. The studies have also shown that when a 250×6 pipeline is coated with a 1 mm thick heat-insulating paint, it will save 126.1 m3 of natural gas per 1 running meter per year. In monetary terms it will be approximately 610 rubles or about $9 (for the first half of 2020). The payback period of this energy-saving measure should not exceed six months. Increasing the thickness of liquid heat insulation layer is not economically feasible. The equivalent fuel economy is approximately 65% when the heat-insulating paint is of 1 mm thickness, and it will increase by only 8% for a thickness of 1.5 mm.