Danae Manolesou

Ms. Danae Manolesou

University of the Aegean - Department of Product and Systems Design Engineering, Ermoúpoli, Notío Aigaío, Greece
orcid
Medical Device Designer, PhD

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Journal of Surgical Research
Verified
Journal Article
Closed access
DMDanae Manolesou
Danae Manolesou
GGGeorge Georgiopoulos
George Georgiopoulos
ALAndreas M. Lazaris
Andreas M. Lazaris
DIMITRIOS SCHIZASDIMITRIOS SCHIZAS
DIMITRIOS SCHIZAS
KSKimon S. Stamatelopoulos
Kimon S. Stamatelopoulos
TPTheodore G. Papaioannou
Theodore G. Papaioannou

1 February 2019 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
DMDanae Manolesou
Danae Manolesou
Theodore G. PapaioannouTheodore G. Papaioannou
Theodore G. Papaioannou
GGGeorgios Georgiopoulos
Georgios Georgiopoulos
DIMITRIOS SCHIZASDIMITRIOS SCHIZAS
DIMITRIOS SCHIZAS
ALAndreas M. Lazaris
Andreas M. Lazaris
DTDimitrios Tousoulis
Dimitrios Tousoulis

20 December 2021 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
DMDanae Manolesou
Danae Manolesou
GKGeorgia Korompili
Georgia Korompili
DDDimitris Davazoglou
Dimitris Davazoglou
ALAndreas M. Lazaris
Andreas M. Lazaris
DIMITRIOS SCHIZASDIMITRIOS SCHIZAS
DIMITRIOS SCHIZAS
Theodore G. PapaioannouTheodore G. Papaioannou
Theodore G. Papaioannou
Background: Hand-sewn anastomosis is a crucial part of aortic reconstruction surgery and significantly affects its outcome. The present study presents a novel, bidirectional surgical needle aimed to improve aortic anastomosis in terms of speed and ease of use. Our objective was to assess the efficacy of the new design in comparison with the conventional needle. Methods: A series of simulations were conducted with COMSOL software in order to perform a fatigue comparative analysis between the new and the conventional needle design. Ease of penetration into a piece of polydimethylsiloxane was evaluated. Lastly, the prototype was tested under in-vitro conditions in comparison with the conventional needle. Results: Based on fatigue analysis, the new needle design improves durability, provided the two tips are equally used. The polytetrafluoroethylene coating improves penetration into the tissue by 7% to 17%, while electropolishing improves penetration up to 19%. When using the novel needle design, the average anastomotic task completion time was significantly reduced by 22% and the overall distance of hand movements was significantly reduced by 20%. Conclusions: The proposed design exhibited a shorter anastomotic time and seems promising in relation to ease of use and simplicity of the anastomotic technique it introduces.